Safety Devices - Fujitsu AUU7RLF Design & Technical Manual

2/3/4 rooms type
Hide thumbs Also See for AUU7RLF:
Table of Contents

Advertisement

11.

SAFETY DEVICES

Model and type
Compact Cassette
Slim Duct
Wall Mounted
Floor
PCB fuse
AUU7RLF
AUU9RLF
250V 3.15A
AUU12RLF
AUU18RLF
ARU7RLF
ARU9RLF
ARU12RLF
250V 3.15A
ARU18RLF
ARU24RLF
ASU7RLF1
ASU9RLF1
250V 3.15A
ASU12RLF1
ASU7RLF
ASU9RLF
ASU12RLF
250V 3.15A
ASU9RLS2
ASU12RLS2
ASU15RLS2
ASU18RLF
250V 3.15A
ASU24RLF
AGU9RLF
AGU12RLF
250V 3.15A
AGU15RLF
- (01 - 117) -
Fan motor
Terminal
thermal
thermal fuse
protector
OFF: 212 ± 18°F
(100 ± 10°C)
ON: 203 ± 18°F
(95 ± 10°C)
OFF: 275 ± 27°F
(135 ± 15°C)
ON: 239 ± 27°F
(115 ± 15°C)
OFF: 221 ± 18°F
(105 ± 10°C)
ON: 194 ± 18°F
(90 ± 10°C)
OFF: 230 ± 27°F
(110 ± 15°C)
ON: 203 ± 27°F
(95 ± 15°C)
OFF: 216°F
OFF: 320 ± 45°F
(OFF: 102°C)
(160 ± 25°C)
ON: 230 ± 45°F
(110 ± 25°C)
OFF: 302 ± 27°F
(150 ± 15°C)
OFF: 216°F
ON: 248 ± 27°F
(OFF: 102°C)
(120 ± 15°C)
OFF: 302 ± 27°F
(150 ± 15°C)
OFF: 216°F
ON: 248 ± 27°F
(OFF: 102°C)
(120 ± 15°C)
Float
switch

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents