Fujitsu AUU7RLF Design & Technical Manual page 14

2/3/4 rooms type
Hide thumbs Also See for AUU7RLF:
Table of Contents

Advertisement

4 Rooms
z
No.
room 1
1
18
Ü1
2
7
3
7
4
7
5
7
6
7
7
7
8
7
9
7
10
7
11
9
12
9
13
9
14
9
15
9
16
9
17
9
18
12
19
12
20
7
21
7
22
7
23
7
24
7
25
7
26
7
27
7
28
7
29
7
30
7
31
9
Notes) 7: 7,000Btu/h, 9: 9,000Btu/h, 12: 12,000Btu/h, 15: 14,000Btu/h, 18: 18,000Btu/h, 24: 24,000Btu/h models
Ü 1: The optional kit "K9FZ1818 (UTP-MU36A2)" shall be necessary for the dual zone system "18+18".
Ü 2: Wall mounted type ASU18RLF can not be connected in this combination.
AOU36RLXFZ1
room 2
room 3
room 4
18
-
Ü1
7
15
7
18
7
24
9
12
9
15
9
18
12
12
12
15
12
18
9
9
9
12
9
15
9
18
12
12
12
15
12
18
12
12
12
15
7
7
7
7
7
7
7
7
7
7
7
9
7
9
7
9
7
12
9
9
9
9
9
9
- (01 - 10) -
total
-
36
-
29
-
32
-
38
-
28
-
31
-
34
-
31
-
34
-
37
-
27
-
30
-
33
-
37
-
33
-
36
-
39
-
36
-
39
7
28
9
30
12
33
15
36
18
39
Ü2
9
32
12
35
15
38
12
38
9
34
12
37
9
36

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents