Fujitsu AUU7RLF Design & Technical Manual page 151

2/3/4 rooms type
Hide thumbs Also See for AUU7RLF:
Table of Contents

Advertisement

FUNCTION SETTING
(3) Press the FAN button so that the "Function number" display flashes. Then, press either the
SET TEMP. p button or the SET TEMP. q button to set up the function number.
(4) Press the FAN button so that the "Setting number" display flashes. Then, press either the
SET TEMP. p button or the SET TEMP. q button to set up the setting number.
(5) Pressing the START/STOP button, confirm the setting.
(The data will be transferred to the indoor unit.)
When the data was not set up on the indoor
unit (-- is displayed.)
Set up the data again according to the
procedure in step (3), (4) above.
FUNCTION DETAILS
Refer to 13-5. FUNCTION DETAILS
Function number
Setting number
Ex.) Function number : 30, Setting number : 01
NOT GOOD
When the data was normally set up on the indoor
unit.
- (01 - 147) -
GOOD

Hide quick links: