INDOOR UNIT: 7,000Btu (AOU36RLXFZ1)
COOLING
 1
Indoor unit is
higher than
outdoor unit.
Height
difference
H
 2
Indoor unit
is lower than
outdoor unit
HEATING
 1
Indoor unit is
higher than
outdoor unit.
Height
difference
H
 2
Indoor unit
is lower than
outdoor unit
Indoor unit
Connection pipe
 1 Indoor unit is higher than outdoor unit.
5m
16ft.
15m
49ft.
-
10m
33ft.
-
7.5m
25ft.
-
5m
16ft.
0.995
0m
0ft.
1.003
-5m
-16ft.
1.003
-7.5m
-25ft.
-
-10m
-33ft.
-
-15m
-49ft.
-
5m
16ft.
15m
49ft.
-
10m
33ft.
-
7.5m
25ft.
-
5m
16ft.
0.990
0m
0ft.
0.990
-5m
-16ft.
0.985
-7.5m
-25ft.
-
-10m
-33ft.
-
-15m
-49ft.
-
Height difference H
H
Outdoor unit
- (04 - 46) -
Pipe length
7.5m
10m
15m
25ft.
33ft.
49ft.
-
-
0.955
-
0.976
0.962
0.988
0.980
0.966
0.992
0.984
0.970
1.000
0.992
0.978
1.000
0.992
0.978
1.000
0.992
0.978
-
0.992
0.978
-
-
0.978
Pipe length
7.5m
10m
15m
25ft.
33ft.
49ft.
-
-
0.976
-
0.991
0.976
1.000
0.991
0.976
1.000
0.991
0.976
1.000
0.991
0.976
0.995
0.986
0.971
0.993
0.984
0.969
-
0.981
0.966
-
-
0.961
Outdoor unit
H
Indoor unit
Connection pipe
 2 Indoor unit is lower than outdoor unit.
20m
25m
66ft.
82ft.
0.941
0.927
0.949
0.935
0.952
0.939
0.956
0.942
0.964
0.950
0.964
0.950
0.964
0.950
0.964
0.950
0.964
0.950
20m
25m
66ft.
82ft.
0.957
0.938
0.957
0.938
0.957
0.938
0.957
0.938
0.957
0.938
0.952
0.933
0.950
0.931
0.947
0.929
0.943
0.924