Specifications - Fujitsu AUU7RLF Design & Technical Manual

2/3/4 rooms type
Hide thumbs Also See for AUU7RLF:
Table of Contents

Advertisement

1.

SPECIFICATIONS

Model name
Power source
Available voltage range
Connectable indoor unit
Combination of indoor unit
Cooling
Capacity
Heating
Cooling
Input power
Heating
Cooling
Current
Heating
EER
Cooling
SEER *1
Cooling
COP
Heating
HSPF *1
Heating
Starting current
Cooling
Maximum operating
current *2
Heating
Type × Q'ty
Cooling
AirFlow
rate
Fan
Heating
Type × Quantity
Motor
Output
Cooling
Sound pressure level
Heating
Dimension
(H x W x D)
Fin pitch
Rows × Stages
Heat
exchanger
Pipe type (Material)
Type (Material)
Fin
Surface treatment
Type × Quantity
Compressor
Motor output
Type
Refrigerant
Charge
Refrigerant oil
Type
Material
Enclosure
Color
Net
Dimensions
(H x W x D)
Gross
Net
Weight
Gross
Liquid
Size
Gas
Method
Pre-charge length (Total)
Max. length (Total)
Connection
Max. length (Each)
pipe
Min. length (Total)
Min. length (Each)
Max. height difference between
Outdoor Unit and each Indoor Units.
Max. height difference between
Indoor Units.
Cooling
Operation range
Heating
Note:
1. Specifications are based on the following conditions.
Power source of specifications : 230V
Pipe length : 24.6ft.(7.5m), Height difference : 0 ft.(0m) [Outdoor unit - Indoor unit]
Cooling: Indoor temperature of 80°F(26.7°C)DB / 67°F(19.4°C)WB,and outdoor temperature of 95°F(35°C)DB/75°F(23.9°C)WB.
Heating: Indoor temperature of 70°F(21.1°C)DB / 60°F(15.6°C)WB,and outdoor temperature of 47°F(8.3°C)DB/43°F(6.1°C)WB.
*1: Test conditions are based on AHRI 210/240.
*2: The maximum current is the maximum value when the operated within the operation range.
2. For other combination, refer to the combination table.
3. The protective function might work when using it outside the operation range.
Number
Total capacity range
ASU9RLF1 + ASU7RLF1 x 2
ASU9RLF + ASU7RLF x 2
Btu/h
Rated
kW
Btu/h
Min. - Max.
kW
Btu/h
Rated
kW
Btu/h
Min. - Max.
kW
Rated
Max.
kW
Rated
Max.
Rated
A
Rated
Btu/W
-
Rated
W/W
-
A
A
3
CFM (m
/h)
W
Rated
dB (A)
in.(mm)
FPI
W
lbs. (g)
in. (mm)
lbs. (kg)
in. (mm)
ft. (m)
°F (°C)
- (03 - 01) -
AOU24RLXFZ
1Ø 208/230V 60Hz
187-264V
2 to 3
14,000 to 27,000 Btu/h
non-Duct
Duct
or
ARU12RLF x 2
22,000
22,000
6.42
6.42
6,100 - 27,000
6,100 - 25,000
1.8 - 7.9
1.8 - 7.3
24,000
24,000
7.02
7.02
6,800 - 29,800
6,800 - 27,400
2.0 - 8.7
2.0 - 8.0
1.76
2.08
2.60
2.84
1.73
2.05
2.93
2.93
7.7
9.1
7.6
9.0
12.50
10.60
18.00
15.50
4.04
3.42
9.50
9.00
9.0
13.7
13.7
13.7
13.7
Propeller × 1
1,942 ( 3,300 )
1,942 ( 3,300 )
DC motor × 1
100
51
52
26-7/16 × 35-7/16 × 1-7/16 (672 × 900 × 36.38)
18
2 × 32
Grooved H-pin (Copper)
Corrugate (Aluminum)
Corrosion resistance (Blue Fin)
DC TWIN ROTARY × 1
1,100
R410A
4lbs. 14oz. (2,200)
POE
Painted galvanized steel
BEIGE
(Approximate color of MUNSELL 10YR 7.5/1.0NN)
27-9/16 × 35-7/16 × 13 (700 × 900 × 330)
32-7/8 × 41-5/16 × 17-1/2 (835 × 1,050 × 445)
124 (56)
139 (63)
Ø1/4 (Ø6.35) x 3
Ø3/8 (Ø9.52) x 2 + Ø1/2 (Ø12.7) x 1
Flare
98 (30)
164 (50)
82 (25)
49 (15)
16 (5)
49 (15)
33 (10)
14 to 115 (-10 to 46)
5 to 75 (-15 to 24)
Mix
22,000
6.42
6,100 - 26,000
1.8 - 7.6
24,000
7.02
6,800 - 28,600
2.0 - 8.4
1.90
2.72
1.88
2.93
8.4
8.3
11.55
16.75
3.74
9.25
13.7
13.7

Hide quick links: