SYSTEM OPERATION AND EQUIPMENT
MAIN CONTROLS
SHOREPOWER
MAIN #1
OFF
OFF
1. Blower Switch
2. Start/Stop Switch
The generator is used to provide AC power when
shore power is not available.
1. Inspect the generator seawater intake strainer
basket for accumulated debris and clean as
necessary.
2. Make sure the generator seacock is open.
3. Turn OFF the two AC main circuit breakers.
4. Move the slide covers over both AC main
circuit breakers.
5. Turn ON the blower and operate it for at least
four minutes.
6. Push the START side of the generator's
Start/Stop switch. Allow generator to operate
for at least one minute to stabilize voltage.
7. Move the generator switch and the transfer
switch to the ON position.
8. Switch the respective branch breakers below it
as needed. In this configuration, all
components can be used with power supplied
by the generator up to a maximum of 30 amps.
FORMULA
GENERATOR
OFF
ON
ON
1
Generator Control Panel
CRUISER/SUPERSPORT
SHOREPOWER
MAIN #2
GENERATOR CONTROLS
BLOWERS
Figure 5-8
9. Do not operate the generator in conjunction
with high speed operation of the boat. The
resulting reduction in water flow to the
generator could damage the unit's water pump
impeller.
!
DANGER
Carbon monoxide gas (CO) is colorless,
odorless and extremely dangerous. All
engines and fuel burning appliances
produce CO as exhaust. Direct and
prolonged exposure to CO will cause
BRAIN DAMAGE or DEATH. Signs of
exposure to CO include nausea, dizziness
and drowsiness.
Stop the generator by pressing the STOP side of
the Start/Stop switch. Close the generator's
seacock.
TRANSFER
ON
ON
START
STOP
2
FOR068
!
5-9