Degree
Code
Error
15
Error
16
Error
17
Information 18
Information 19
© 2013 Dürkopp Adler AG
Error or information description Remedial measures
Excess sewing motor current,
internal current increase >25A
Maximum speed exceeded
AC RDY time-out , intermediate
circuit voltage has not reached the
defined threshold in the given time.
No valid data on internal EEprom
No valid data on internal EEprom
Error, warning and information messages
- Check wiring in the machine distributor and change if
necessary
- Test motor phases and check for value
- Replace control unit
- Replace encoder
- Check mains voltage
- If mains voltage OK, replace control unit
- Check the connection of the Mach ID
- Turn off the control unit, wait until LEDs are off,
restart
- Update software
- Check the connection of the Mach ID
- Turn off the control unit, wait until LEDs are off,
restart
- Update software