AERMEC GLLI10N User And Installation Manual

Delivery and intake frame inverter

Advertisement

CORNICE DI MANDATA E D'ASPIRAZIONE INVERTER
DELIVERY AND INTAKE FRAME INVERTER
GRILLE DE SOUFFLAGE ET D'ASPIRATION INVERTER
AUSBLAS- UND ANSAUGGITTER INVERTER
PLAFON DE ENVÍO Y DE ASPIRACIÓN INVERTER
GLLI10N
GLLI20N
MANUALE D'USO E INSTALLAZIONE
U S E A N D I N S TA L L AT I O N M A N UA L
M A N U E L
D ' U T I L I S A T I O N
E T
D ' I N S T A L L A T I O N
B E D I E N U N G S -
I N S T A L L A T I O N S A N L E I T U N G
M A N UA L D E U S O E I N S TA L AC I Ó N
AGLLI10/20NFJ 07/11_4528572_00
U N D

Advertisement

Table of Contents
loading

Summary of Contents for AERMEC GLLI10N

  • Page 1 M A N UA L D E U S O E I N S TA L AC I Ó N CORNICE DI MANDATA E D’ASPIRAZIONE INVERTER DELIVERY AND INTAKE FRAME INVERTER GRILLE DE SOUFFLAGE ET D'ASPIRATION INVERTER AUSBLAS- UND ANSAUGGITTER INVERTER PLAFON DE ENVÍO Y DE ASPIRACIÓN INVERTER GLLI10N GLLI20N AGLLI10/20NFJ 07/11_4528572_00...
  • Page 2 Alle in diesem Handbuch enthaltenen Informationen auf- sich für die Garantiearbeiten als erforderlich erweisen sollten. merksam und vollständig lesen. Insbesondere auf die Die AERMEC S.p.A. übernimmt keine Haftung für Schäden aus Benutzungsanweisungen mit den Hinweisen "VORSICHT" oder dem unsachgemäßen Gebrauch des Gerätes und der teilweisen "ACHTUNG"...
  • Page 3 Before taking measurements on the unit, it is necessary to discharge all elec- DESCRIPTION GLLI10N (600x600) supervisor system. and delivery through the adjustable, GLLI20N (840x600) The FCLI units are available in two basic outer slots. In plastic, colour RAL 9010,...
  • Page 4 VMF-E4 VMF SERIES THERMOSTAT CONTROL PANEL, WALL MOUNTING Wired control panel, user interface for thermostats incorporated in GLLI10N and GLLI20N grille units, and for all other VMF range thermostats. The panel must be used with VMF range thermostats and operates...
  • Page 5 ACCESSORIES VMF SYSTEM SUPERVISION VMF-E5B / E5N SYSTEM'S MAIN SUPERVISION INTERFACE WARNING: the VMF-E5 panel allows the management VMF-E5B of the individual masters; the slave units connected VMF-E5N to each master cannot be individually managed from the VMF-E5 panel, but they acquire the settings of the master to which they are connected.
  • Page 6 GLLI_N/VMF-E4 CONNECTION Connect the VMF-E4 to the GLLI_N ther- length 30 meters); connect the terminals tion by inserting the connector plug in the mostat; this connection must be made on the back of the VMF-E4 to the supplied dedicated terminal on the GLLI_N card (as using a 4-pole shielded cable (maximum control board, and complete the connec- shown).
  • Page 7 ELECTRONIC BOARD CONNECTION TTL-WITH VMF E4 CE EXTERNAL CONTACT TX/RX ECONOMY CONTROL GND/TTL MODE WINDOW CONTROL TX/RX TTL-SERIAL MODBUS RS485 M26 CONTROL BOARD EXTERNAL CONTACT CONNECTION CONNECTION (ECONOMY CONTROL) MODBUS (WINDOW CONTROL) RS485 SERIAL TTL NETWORK CONNECTION TTL NETWORK CONNECTION WITH VMF-E4 AGLLI10/20NFJ 07/11_4528572_00...
  • Page 8 IR CONNECTION (THERMOSTAT RECEIVER) 4-PIPE PROBE CONNECTOR CONNECTION The display card will physically connect to the GLLI_N control box through a 4-pole cable as shown above CONNECTOR CONNECTION TO THE CONTROL BOARD M2 L: power supply input of the Voltage M10 Neutral reference for output V1, V2 M17 Out 0-10V: Inverter reference card: 230 Vac, current 10 A...
  • Page 9 DISPLAY CARD OPERATION The thermostat can be coupled to a alarms, probe read-code) The new display card must have a layout display card which must meet the • Starting point of the special commands as shown in the following figures: following requirements: such as: correction of the probe reading, display of the data read by the probes,...
  • Page 10: Probe Reading

    AUTOTEST The activation of the ventilation and the conditions, can be "forced" in the self- valve of the branch corresponding to test mode so as to verify the correct the operating season, even in unsuitable functioning of the connections and the water or environment temperature windings of the electric motor.
  • Page 11 AMBIENT PROBE READING CORRECTION For installations of cassette fan coils that tion of the probe can only be performed use the ambient probe positioned in the if the fan coil is in standby, the only LED box, the correction of the probe difference is the selection of the correc- reading may be deemed necessary to tion that is linked to the season of the...
  • Page 12: Ventilation Control

    VENTILATION CONTROL Thermostat-controlled ventilation: The Continuous ventilation: The continuous tilation will always be managed with choice of the regulation according to ventilation is selected by means of dip3 thermostatically controlled logic. thermostatically controlled ventilation that must be set to On. In practice the The following table shows the ventilation (dip3 OFF) foresees the switching off continuous ventilation provides ventila-...
  • Page 13: Anti-Freeze Protection

    HOT/COLD MODE CHANGE OVER WATER SIDE SEASON CHANGEOVER If the thermostat is configured for use are shown in the table below. cold ventilation in the winter season, without a valve (dip1 OFF) or with a In this configuration, the indications of and on the other side to check the turn- probe upstream of the valve (dip2 ON), the left LED correspond to the active...
  • Page 14: Sleep Function

    EXTERNAL CONTACT LOGIC The thermostat also includes an external contact that allows to set it to OFF if it is closed (except if the thermostat is in anti-freeze mode or as a slave in the TTL network). This contact could be useful to manage inputs such as window contacts, faulty circulation pump, etc.
  • Page 15: Dip Switch Setting

    DIP-SWITCH SETTING Turn off the power to the unit. This **Warning: if the thermostats are position of the probe. operation should be carried out in the inserted in systems with Centralised installation phase, by suitably trained Control or Supervisor (e.g. VMF-E5), and qualified personnel only.
  • Page 16: Additional Controls

    ADDITIONAL CONTROLS EMERGENCY FUNCTIONING The two following failure cases are fore- dead band below the Cooling setpoint, The fan is off seen when the thermostat operates in it switches to the Heating mode. - AUTO, V1, V2, V3 mode: the described manner. - The turning on/off of the resistance The valve is always open.
  • Page 17: Operating Principle

    CASSETTE LOCAL NETWORK The VMF-FCL thermostat has been de- signed to communicate with all thermo- LUNGHEZZA MAX.30 (m) stats of the VMF family through a dedicat- ed serial based on standard TTL logic and low throughput. This serial communica- tion is essential for the exchange of in- VMF-E4 formation within small fan coil networks.
  • Page 18 TTL NETWORK MANAGEMENT No Master-Slave communication: the local probe) follows what described in slave fan coil cyclically await the zone the next paragraph. settings from the master fan coil. If for Slave without Ambient Probe some reason a slave fails to communi- The Slave thermostat cards enter into cate with the master, it switches OFF emergency mode not only if the local...
  • Page 19: Installation

    "persons with (GLLI10N) for correct machine heating specific technical skills"). (20° opening) and cooling (10° open- In the specific case of electrical wirings, ing) operation.
  • Page 20 F2, as shown in the image out any procedures on the unit. below. ELECTRICAL CONNECTIONS WITH GLLI10N AND GLLI20N ACCESSORIES Before installing the electric box, the network cable, and probe and valve configuration of the electronic board cables based on system requirements.
  • Page 21 SCHEMI ELETTRICI • WIRING DIAGRAMS • SCHEMAS ELECTRIQUES • SCHALTPLÄNE • ESQUEMAS ELÉCTRICOS LEGENDA • READING KEY • LEGENDE • LEGENDE • LEYENDA AL • Supply Bomba de desagüe de condensado = Componenti non forniti = Alimentatore Components not supplied MV = Motore ventilatore •...
  • Page 22 SCHEMI ELETTRICI • WIRING DIAGRAMS • SCHEMAS ELECTRIQUES • SCHALTPLÄNE • ESQUEMAS ELÉCTRICOS FCLI 230V 50Hz GLLI10N / GLLI20N WMF-SW1 CLOSED FOR FCLI TX/RX GND-TTL MODE TX/RX 1 2 3 4 1 2 3 4 VHL1 VHL20 VHL2 VHL22 Dis. 5490480_03 Gli schemi elettrici sono soggetti ad un continuo aggiornamento, è...
  • Page 23 SCHEMI ELETTRICI • WIRING DIAGRAMS • SCHEMAS ELECTRIQUES • SCHALTPLÄNE • ESQUEMAS ELÉCTRICOS 230V 50Hz FCLI GLLI10N / GLLI20N WMF-SW1 CLOSED FOR FCLI TX/RX GND-TTL MODE TX/RX 1 2 3 4 1 2 3 4 VHL1 VHL20 VHL2 VHL22 Dis. 5490481_03 FCLI_VL Gli schemi elettrici sono soggetti ad un continuo aggiornamento, è...
  • Page 24 AERMEC S.p.A. si riserva la facoltà di apportare in qualsiasi momento tutte le modifiche ritenute necessarie per il miglioramento del prodotto. Les données mentionnées dans ce manuel ne constituent aucun engagement de notre part. Aermec S.p.A. se réserve le droit de modifier à tous moments les données considérées nécessaires à...

This manual is also suitable for:

Glli20n

Table of Contents