USE AND INSTALLATION MANUAL
FK260 - FK360
EN
5140901_01
Aermec. 16.01. 5140901_01

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FK360 and is the answer not in the manual?

Questions and answers

Summary of Contents for AERMEC FK360

  • Page 1 Energy efficiency USE AND INSTALLATION MANUAL FK260 - FK360 5140901_01 Aermec. 16.01. 5140901_01...
  • Page 2: Table Of Contents

    SUMMARY WARNINGS .................4 1.1. GENERAL WARNINGS ................. 4 1.2. WARNINGS FOR R32 COOLANT GAS ..........4 1.3. R32 GAS ADVANTAGES ..............4 1.4. WARNINGS FOR MAINTENANCE OR REPAIR ......4 1.5. FILLING R32 COOLANT GAS ............4 1.6. DISPOSAL OF R32 COOLANT GAS ..........4 1.7.
  • Page 3 Unlawful disposal of the product by the user may result in the application of administrative fines based on current laws All specifications are subject to change without prior notice. Although every effort has been made to ensure precision, Aermec does not assume any...
  • Page 4: Warnings

    Appliance filled with flammable gas R32. For repairs, refer to manufacturer’s instructions only. Be aware that refrigerants do not contain odour. Read specialist’s manual. Charge amount “kg” ≤1,2 Minimum room area m window mounted 11,2 12,4 13,6 16,3 17,8 19,3 Aermec. 16.01. 5140901_01...
  • Page 5: Warnings For The Installer

    Only replace the fuses with others Incorrect operations could cause electric identical to the original ones. shocks, water leaks, fires etc. Contact your After Sales Service, these operations must only be carried out by “Personnel with the Aermec. 16.01. 5140901_01...
  • Page 6: Warnings For The User

    • Do not place objects on the external part and do not climb on top. • In the event of issues with the air Aermec. 16.01. 5140901_01...
  • Page 7: Unit Type

    Possibility to adjust the flow of air upward or downward. • Timer for setting operation with a clock (turning on or switching off ). • Easy installation and maintenance • Automatic operating modes suitable for the various installation contexts (room, office, restaurant). Aermec. 16.01. 5140901_01...
  • Page 8: Operating Limits

    (3) The Nominal Input Power (Nominal Input Current) is the Maximum Input Electrical Power (Maximum Input Current) from the system, in accordance with the Standards EN-60335-1 and EN-60335-2-40 (4) Sound Pressure measured in a semi anechoic chamber at a distance of 1,5m from the front of the unit Aermec. 16.01. 5140901_01...
  • Page 9: Description Of Components

    DESCRIPTION OF COMPONENTS Outer side Inner side Air filter Aermec. 16.01. 5140901_01...
  • Page 10: Installation

    6~10mm proper fixing and insulation. • Use a suitably sized bracket that can support the weight of the unit. Supporter Support • Level the bracket. Horizontal line Horizontal line Aermec. 16.01. 5140901_01...
  • Page 11: Minimum Technical Clearances

    If the sound of the spraying is bothersome, the cap can be removed from the base (this can cause a slight loss of performance). Base cap for condensate drainage Aermec. 16.01. 5140901_01...
  • Page 12: Electrical Warnings

    Water pipes: Some parts of the water pipes are made of plastic materials and are not suitable FK 360 for earthing. Gas pipes: If there is an accidental electrical discharge from the air conditioner, it could easily cause a fire or even an explosion. Aermec. 16.01. 5140901_01...
  • Page 13: Wiring Diagrams

    YEGN BU YE Schaltkasten Bedientafel Überstrom- auslöser YEGN Konden - Kompressor sator Ventilator Motor Symbol Description White Yellow YEGN Yellow / Green Green Brown Blue Black CAP. Condenser COMP Compressor Stromlaufplan Earth Fensterklimageräte FK 260 FK 360 Aermec. 16.01. 5140901_01...
  • Page 14: Operating Test

    Are the air inlet and outlet on the indoor unit Poor performance. ✍ free of obstacles? Have the pipe length and refrigerant charge Poor performance. Impossible to check the ✍ been recorded? amount of refrigerant added. Aermec. 16.01. 5140901_01...
  • Page 15: Maintenance

    The device should not be used by children as a game. • Instruct the customer on how to use the system by showing him/her the accompanying manual. • Make sure that the power user falls within the tolerance (+ / -10%). Aermec. 16.01. 5140901_01...
  • Page 16: Control Panel

    The unit will continue to work properly also when the LED is on. After cleaning the air filter it is necessary to push FILTER button to switch-off the LED and the function. Push the FILTER button again to set this function. WARNING: Wait 3 minutes before turning the unit back on after turning it off, or after a blackout. Aermec. 16.01. 5140901_01...
  • Page 17: Remote Control

    1°C. When + or - is pressed for 2 seconds the set temperature on the remote control changes quickly. Release the button once the desired temperature is reached. Function 2 When setting the On or Off Timer, press + or - to adjust the time. Aermec. 16.01. 5140901_01...
  • Page 18 Infra-red signal (visible on the remote control with the symbol Sleep button Press this button to turn on the Sleep function. Press thus button to cancel the Sleep function. Under the FAN and DRY functions, this function is not available. Aermec. 16.01. 5140901_01...
  • Page 19: Replacing The Remote Control Batteries

    The remote control can emit a signal up to a maximum distance of 8 metres. The unit may be influenced by signals transmitted by remote controls of televisions, neon lights or wireless telephones/devices or other equipment used in the same room. Aermec. 16.01. 5140901_01...
  • Page 20: Recommended Operations

    Clean the filter regularly. A dirty filter significantly reduces the dehumidification abilities. It is recommended that you clean the filter every 2 weeks. Air out the room from time to time. This must be done while the unit is turned off. Aermec. 16.01. 5140901_01...
  • Page 21: Alarms Display

    Contact specialised personnel or the Aermec Assistance Service. 4-way valve malfunction Contact specialised personnel or the Aermec Assistance Service. If alarm codes other than those shown in the table appear, please contact the Aermec Assistance Service. WARNING: Turn off the unit immediately and...
  • Page 22: Safety Standards Due To Gas R32

    Verify that the maintenance area or the room area meet the requirements on the label. • Verify that the maintenance area is well ventilated. The ventilation status must be maintained for the entire duration of the operation. Aermec. 16.01. 5140901_01...
  • Page 24 Les données mentionnées dans ce manuel ne constituent aucun Im Sinne des technischen Fortsschrittes behält sich Aermec S.p.A. engagement de notre part. Aermec S.p.A. se réserve le droit de modifier vor, in der Produktion Änderungen und Verbesserungen ohne à tous moments les données considérées nécessaires à l’amelioration Ankündigung durchzuführen.