Workflow

1. Network Setup: Setting a Static IP, enabling external access via port forwarding
a. LAN Setup: static IP address assigned by site IT staff
b. Port Setup: forward ports to allow Device commands to be sent from I-View Now
2. Configure SMTP email: This will be used to communicate alerts and alarms to I-View Now. The SMTP server and
SMTP ID provided on the "Installer Data" Worksheet will be used here
3. User Setup: Change the default administrator password. I-View Now will be using this password to log into the
device. I-View Now suggests using the suggested password on the "Installer Data" worksheet.
4. Recording Setup: The DVR will be set to record by schedule or by events. Event recording will only record when
either a motion or alarm event is detected. Scheduled recordings occur during the scheduled time.
5. Alarm Input Setup: Here the technician will be setting up the alarm inputs on the back of the DVR to perform
two actions: 1) Trigger recording on all connected cameras. And most importantly, 2) Send SMTP (email) alert to
I-View Now upon the event of an alarm.
6. Motion Detection Setup: activate video motion recording for desired cameras.
7. Configure I-View Now Entry Delay: Entry delay is configured through the I-View Now portal.
8. Test: Here you will test the individual inputs on the DVR as they are connected to your alarm panel relays or
other input devices. It is recommended that you test all inputs for functionality and to ensure the proper
configuration has been setup in the I-View Now portal.
9. Trouble Shooting: This section is provided to help the technician troubleshoot common problems encountered
while installing DVR's.