Download Print this page

Maintenance Instruction - Fortress Technologies FSAV10M14 User Manual

Dc inverter split air conditioner

Advertisement

MAINTENANCE INSTRUCTION

Cleaning the Grille, Case and Remote Control
Turn the unit off before cleaning. To clean and wipe
with a soft and dry cloth. Do not use bleach or abrasives.
NOTE: Supply power must be disconnected before
cleaning the indoor unit.
Wipe the indoor unit with a dry cloth if it is dirty.
Do not use a chemically treated cloth or duster to
clean the unit.
Do not use benzine, thinner, polishing powder, or
similar solvents for cleaning. These may cause
the plastic surface to crack or deform.
Filter Handle
Cleaning the air filter
A clogged air filter reduces the cooling / heating efficiency of
this unit. Clean the filter every 2 weeks is recommended.
1. Lift the indoor unit panel up to an angle until a click sound
is heard.
2. Hold the handle of the air filter and lift it up slightly
to take it out from the filter holder, then pull it
downwards.
3. Remove the air filter from the indoor unit.
CAUTION
9 9
4. Remove the air filter and air freshening filter from its
support frame.
(The air freshening filter include : Silver Ion filter /Vitamin C
filter . The removing and installation methods are slightly
different, see the pictures marked
on the left.
4
(Clean the air freshening filter at least once a month is
recommended.)
5. Clean the air filter and air freshening filter with a vacuum
cleaner or water, then dry them in a cool and dry place.
6. Install the air freshening filter back into position.
Insert the upper portion of the air filter back into the
unit, make sure that the left and right edges line
up correctly, and place the air filter back into position.
NOTE
When the unit is not in use for a prolonged period,
please perform the following.
(1) Operate the fan for about half a day to dry inside
of the unit.
(2) Stop the air conditioner and disconnect the power.
Remove the batteries from the remote control.
(3) The outdoor unit requires periodic maintenance
and cleaning. Do not attempt to do this yourself.
Contact your dealer or service provider.
Checks before operation
Check if the wiring is broken off or disconnected.
Check if the air filter is installed.
Check if the air outlet or inlet is blocked after the
air conditioner has not been used for a prolonged
period.
Caution
Do not touch the metal parts of the unit when
removing the air filter. Injuries can occur when
handling sharp metal edges.
Do not use water to clean inside the air conditioner.
Exposure to water can destroy the insulation and
lead to possible electric shock.
When cleaning the unit, please ensure the
power and the circuit breaker are turned off.