10.1.4
Drain pump
-
The pumps are fastened to the base panel via rubber dampers.
-
To exchange the pumps refer to the working instructions of chapters 10.1.1, 10.1.2 and 10.1.3.
-
It is not necessary to remove the bellows from the tub.
Abb.: 13
10.1.5
Door lock
The door lock is screwed to the front plate with 2 screws.
-
Untighten them (Fig. 14).
-
Then untighten the bellows from the front plate as described in the instructions 10.1.3 (Fig. 7).
Turn the bellows to the inside. Now you can pull out the door lock between the front
plate and the tub and untighten the plug.
Abb.: 14
DGS-TDS-N 11.2004 C.D.
- 53 -
© Electrolux
bellows turned to the inside
Pumps