The Drain Pump; The Recirculation Pump - Electrolux EWM 3000 Service Manual

Frontloading washing machine
Hide thumbs Also See for EWM 3000:
Table of Contents

Advertisement

10.4 The drain pump

Pump control (m3):
In order to pump, the appliance must be switched on (b7/DW), the safety level and the floating switch
have to be in empty position. The electronic controls the pump by a triac, depending on the program.
In case of aqua control the floating switch is in full position and the drain pump is active until
the plug is pulled or the water is removed out of the bottom tray.
The appliance would even pump when the appliance is switched on and the safety level (fS) has reacted.
Over-filling protection!

10.5 The recirculation pump

Recirculation pump:
Connection:
Flowrate:
Power:
Resistance:
Circulation pump control (m22):
The recirculation pump is controled by a triac located on the main electronic board depending on
the program cycle.
DGS-TDS-N 11.2004 C.D.
Drain pump:
Connection:
230V; 50 Hz; Synchron
Flowrate:
22 L/min
Power:
34W +30%
Resistance:
164W +5/-5%
230V; 50 Hz; Synchron
25 L/min
22W +30%
202W +5/-5%
© Electrolux
- 32 -
599 51 13-50 EN

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents