Cleaning and maintenance

Door seal

Check from time to time the door seal and
eliminate eventual possible objects that
could be trapped in the fold.

Drain pump

The pump should be inspected regularly and particularly if
the machine does not empty and/or spin
the machine makes an unusual noise during draining due to objects
such as safety pins, coins etc. blocking the pump.
Proceed as follows:
Disconnect the appliance.
If necessary wait until the water has cooled down.
Open the pump door.
Place a contain-
er close to the
pump to collect
any spillage.
Release the
emergency
emptying hose,
place it in the
container and
remove its cap.
When no more water comes out, unscrew the pump and remove it.
Always keep a rag nearby to dry up spillage of water when removing
the pump.
Remove any
objects from the
pump impeller
by rotating it.
Put the cap
back on the
emergency
emptying hose
P1097
and place the
latter back in its seat.
Screw the pump fully in.
Close the pump door.
72