TEST MODE

✦ Even though this is a self-monitoring supervised
system, the National Burglar and Fire Alarm
Association recommends that all security systems
should be tested manually on a regular basis.
1. The Console must be in Off Mode before switching
to Test Mode.
2. Switch the Console into Test Mode by entering a
user code and pressing TEST.
✴ When the system is switched to the Test Mode, the Console
will sound a "Gong" and four "Beeps".
3. Holding down the TEST button in Test Mode will light
all of the Console's indicators.
✴ The sensor status indicators will fl ash for each sensor
programmed into the Console.
4. Go to each sensor and press its test button or open
and close the protected opening.
5. To test the wireless keypad, press the wireless
keypad's
key.
✴ The Console will make a "Bing" sound as each sensor is
tested, followed by 1-3 beeps indicating signal strength with
3 beeps being the strongest signal.
✴ As each sensor is tested, the sensor status indicator for the
sensor will stop fl ashing and return to showing the current
status of the sensor.
6. Continue testing until there are no fl ashing sensor
status indicators.
SENSOR TYPE
AUTOMATION
EMERGENCY
PANIC
FIRE
PERIMETER
EXIT/ENTRY
INTERIOR
CHIME
2-BUTTON ARM/DISARM (LEFT)
2-BUTTON AUTOMATION (RIGHT)
EMERGENCY (BOTH BUTTONS)
2-BUTTON ARM (LEFT)
2-BUTTON DISARM (RIGHT)
EMERGENCY (BOTH BUTTONS)
ENVIRONMENTAL
INTERIOR HOME
CAN BE HOME MODE USING PROGRAMMING STEP 50
‡ CAN BE CHIME MODE USING PROGRAMMING STEP 51
20
SENSOR OPERATION IN EACH CONSOLE MODE
OFF MODE
DEACTIVATED
DEACTIVATED
DEACTIVATED
LEFT BUTTON SWITCHES SYSTEM TO AWAY MODE †
IF ALARM MEMORY IS ACTIVE, SWITCHES SYSTEM TO OFF MODE ‡
LEFT BUTTON SWITCHES SYSTEM TO AWAY MODE †
IF ALARM MEMORY IS ACTIVE, SWITCHES SYSTEM TO OFF MODE ‡
DEACTIVATED
✎ NOTE: If the Console is left unattended in Test
Mode, it will automatically switch back to Off Mode
after three minutes.
✦ When directly connecting (without a telephone
line) to the DVS-1200 with the RA-2400 remote
access software (Version 1.3 or later), press the
EMERGENCY key while in Test Mode to cause the
Console to connect to the modem.
CHIME MODE
ACTIVATES AND DEACTIVATES THE AUTOMATION OUTPUT
ARMED 24-HOURS - TRIGGERS EMERGENCY ALARM
ARMED 24-HOURS - TRIGGERS SILENT PANIC ALARM
ARMED 24-HOURS - TRIGGERS FIRE ALARM
CHIME
CHIME
DEACTIVATED
CHIME
ARMED 24-HOURS - TRIGGERS ANNUNCIATION ONLY
DEACTIVATED
Console Zone Table
TEST MODE
START IN OFF
(OPTIONAL)
YOUR
USER
CODE
1 GONG
TEST
& 4 BEEPS
DONE
HOME MODE
INSTANT BURGLARY ALARM
DELAYED BURGLARY ALARM
INSTANT BURGLARY ALARM UNLESS
DEACTIVATED
ACTIVATED DURING AN ENTRY
DELAY, THEN IT IS DELAYED
LEFT BUTTON SWITCHES SYSTEM TO OFF MODE ‡
RIGHT BUTTON SWITCHES SYSTEM TO OFF MODE ‡
INSTANT BURGLARY ALARM
AWAY MODE