• PX-1981
GENERAL
M
• Input voltage
• Input current
• Usable frequency
• Inrush current
• Efficiency
• Output voltage
• Output current
• Current limitation
• Total fluctuation rate
• Ripple voltage
• Usable temperature range
• Usable humidity range
• Dimensions
• Weight
All stated specifications are subject to change without notice or obligation.
: 90 V–132 V AC or 180 V–264 V AC
: less than 15 A (200 V AC)
less than 20 A (100 V AC)
: 47 Hz–63 Hz
: less than 30 A peak
: more than 75 %
(input voltage; 200 V AC, output voltage; 45 V, output current; 45A)
: DC 45 V ±1.5 V (Input voltage: 200 V AC)
DC 40 V ±1.5 V (Input voltage: 100 V AC)
DC 13.6 V ±1.0 V
: 0–45 A (Output voltage: 45 V DC)
0–30 A (Output voltage: 40 V DC)
0–3.5 A (Output voltage: 13.6 V DC)
: 52 A ±1.0 A (Output voltage: 45 V DC)
35 A ±1.0 A (Output voltage: 40 V DC)
: ±5 % (Output voltage: 40 V or 45 V)
±10 % (Output voltage: 13.6 V)
: less than 2000 mV (P-P)
: –10 ˚C to +40 ˚C; +14 ˚F to +104 ˚F
: 30 % to 85 %
: 182(W)×147.8(H)×346(D) mm;
7.17(W)×5.82(H)×13.6(D) in;
: 6.0 kg; 13.23 lb
1 - 2