4.3 Cable Entry Positions

The electrical supply cables can be routed to
enter the unit from the left or right hand side
(see diagram 8, page 13). There are four cable
entry holes in each upper side panel; one
25mm diameter and three 20mm diameter.
The accessory kit contains a set of cable
glands and snap fit blanking plugs. The cable
glands should be fitted into the cable entry
holes on the side selected for cable entry and
secured in place using the lock nuts supplied.
The remaining four cable entry holes not used
should be blanked off using the appropriate
blanking plugs supplied.
The cable glands must be used to secure the
electrical supply cables when fitted. Failure to
do so can result in the cables straining internal
electrical connections and possible electrical
failure as a result. Failure due to inadequate
cable securing will not be covered by the
warranty.
Front
Panel
Right hand cable
entry holes shown.
Left hand holes
are mirrored in left
hand panel.
Diagram 8 Cable Entry Positions
Top
Panel
20mm
25mm

4.4 Programmable Room Thermostat

The Electromax is supplied with a Danfoss
TP5000 Programmable Room Thermostat. This
is in the accessory kit supplied with your unit.
Follow the installation instructions provided
with the programmable room thermostat for
correct siting and mounting of the unit. If the
radiators are to be fitted with thermostatic
radiator valves (TRV's) the room where the
programmable room thermostat is located
must not have a TRV fitted in compliance with
Building Regulation Part L.
Diagram 9 Programmable Room Thermostat
Installation & Servicing Instructions
13