4.3 Cable Entry Positions

The electrical supply cables can be routed to
enter the unit from the left or right hand side
(see Diagram 8). There are four cable entry
holes in each upper side panel; one 25mm
diameter and three 20mm diameter. The
accessory kit contains a set of cable glands
the side selected for cable entry and secured
in place using the lock nuts supplied. The
remaining four cable entry holes not used
should be blanked off using the appropriate
blanking plugs supplied.
The cable glands must be used to secure the
to do so can result in the cables straining
internal electrical connections and possible
electrical failure as a result. Failure due to
inadequate cable securing will not be covered
by the warranty.
Diagram 8 Cable Entry Positions
Panel
Front
Panel
Right hand cable
entry holes shown.
Left hand holes
are mirrored in left
hand panel.
Top
20mm
25mm

4.4 Programmable Room Thermostat

The Electromax is supplied with a Danfoss
TP5000 Programmable Room Thermostat.
This is supplied in the accessory kit supplied
with your unit. Follow the installation
instructions provided with the Programmable
Room Thermostat for correct siting and
mounting of the unit. If the radiators are to
(TRV's) the room where the Programmable
Room Thermostat is located must not have
a TRV fitted in compliance with Building
Regulation Part L.
Diagram
Programmable Room Thermostat
Installation & Servicing Instructions
13