Epson Stylus C110 Service Manual page 84

Hide thumbs Also See for Stylus C110:
Table of Contents

Advertisement

EPSON Stylus C110/C120/D120
Do not touch or damage the nozzles or the ink supply needles of the
C A U T I O N
Printhead.
6.
Remove the screws (x3) that secure the Printhead, and lift up the Printhead with a
longnose pliers.
1
3
Figure 4-29. Removing Printhead (3)
7.
Disconnect the Head FFC from the connectors (x2) of the Printhead, and remove
the Printhead.
Printhead
Figure 4-30. Removing Printhead (4)
DISASSEMBLY/ASSEMBLY
2
C.B.S. 2.5x8, F/Zn-3C (3±1kgfcm)
Head FFC
Disassembling Printer Mechanism
Tighten the screws in the order given in
Insert the Holder Board Assy. vertically into the CR Unit so as
not to put the assy. on the rib of the Printhead.
After removing/replacing the Printhead, be sure to perform the
A D J U S T M E N T
R E Q U I R E D
specified adjustment. See
Revision B
Figure
4-29.
Chapter 5 " ADJUSTMENT" (p.107)
84