WARNING: If the information in this manual is
not followed exactly, a fire or explosion may
result causing property damage, personal
injury or loss of life.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the
fire department.
Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Gas Fired Vented Room
Heater (Direct Vent)
U
SERS'
O
PERATION and
M
AINTENANCE
This appliance may be installed in an aftermarket
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
local codes.
This appliance is only for use with the type
of gas indicated on the rating plate. This
appliance is not convertible for use with other
gases, unless a certified kit is used.
*Conversion kit required for Propane use
7116 Beatty Dr
Mission, BC V2V 6B4
Canada
31-DVIM33
S/N 200001 And up
I
NSTALLATION
Tested and
listed by
LABTEST Certification Inc
Richmond, British Columbia
ANSI Z21.88-2009/CSA 2.33-2009
M
ANUAL
200-1231
Aug 2013

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 31-DVIM33 and is the answer not in the manual?

Questions and answers

Summary of Contents for Archgard 31-DVIM33

  • Page 1 31-DVIM33 Gas Fired Vented Room Heater (Direct Vent) S/N 200001 And up SERS’ NSTALLATION PERATION and AINTENANCE ANUAL WARNING: If the information in this manual is This appliance may be installed in an aftermarket not followed exactly, a fire or explosion may...
  • Page 2 STATE OF MASSACHUSETTS REQUIREMENTS 5.08: Modifications to NFPA-54, Chapter 10 (2) Revise 10.8.3 by adding the following additional requirements: (a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:...
  • Page 3 INTRODUCTION Congratulations on choosing an Archgard Gas Fireplace! The 31-DVIM33 is one of the most advanced Direct Vent Insert heaters available today. It is solidly designed using the latest technology and manufactured to the highest quality. It is our aim to provide you with an appliance for many trouble-free years of reliable service.
  • Page 4: Table Of Contents

    TABLE OF CONTENTS Caution and Safety Instructions Appliance Certification, Installation Codes and Specifications Rating Plate Control Panel Locations Appliance Dimensions and Minimum Requirements for Fireplace Dimensions Factory Built (metal) Fireplace Requirements Clearance to Combustibles Gas Connections Appliance Description, Leveling the Appliance and Electrical Requirements Glass Door Removal / If Your Glass Should Break Venting Instructions 15-16...
  • Page 5: Caution And Safety Instructions

    31-DVIM33 CAUTION FOR YOUR SAFETY - Do not install or operate your Archgard 31-DVIM33 without reading and understanding this manual. Any installation or operational deviation from this instruction manual voids the Archgard Industries Warranty and may prove hazardous. This appliance must be installed by a qualified gas installer and the installation must conform to the installation codes.
  • Page 6: Appliance Certification, Installation Codes And Specifications

    The listing label is attached to the appliance on the bottom right side of the appliance. A copy is shown on page Please contact Archgard Industries Ltd., if you have any questions regarding the certification of this appliance. INSTALLATION CODES This appliance must be installed by a qualified gas appliance installer.
  • Page 7: Rating Plate

    CAN/CSA C22.1 actuel au Canada et ANSI/NFPA 70 aux É.-U. Cet appareil est certifié pour l’installation dans une chambre à coucher ou une pièce qui sert de chambre. Made in Canada by / Fabrique au Canada par: Archgard Industries Ltd. 7116 Beatty Dr., Mission, B.C. Aug 2013 303-6031-2...
  • Page 8: Control Panel Locations

    31-DVIM33 CONTROL PANEL LOCATIONS The control panels can be mounted in the following different ways. They are shipped in the “Controls In” configuration. They can be moved to the “Controls Out” configuration by removing the two mounting screw on each side and swinging the panels out and replacing the screws.
  • Page 9: Appliance Dimensions And Minimum Requirements For Fireplace Dimensions

    31-DVIM33 MINIMUM FIREPLACE DIMENSIONS Min flue size required 4” (102) x 7” (178) TOP VIEW SIDE VIEW TOP VIEW CONTROLS OUT DIMENSIONS DIMENSIONS “Controls Out” “Controls In” 20-1/4” (514 mm) 20-1/4” (514 mm) TOP VIEW 14” (356 mm) 15 1/2” (394 mm) CONTROLS IN 19”...
  • Page 10: Factory Built (Metal) Fireplace Requirements

    31-DVIM33 Factory –Built (metal) Wood-Burning Fireplace Requirements Any parts that are removed must be saved and re-installed if the insert is ever removed. The damper (A) and grate (B) must be removed The smoke shelf (C), internal baffles (D), screen ( E), masonry lining or refractory (G and I), and metal or glass doors (F) may be removed.
  • Page 11: Clearance To Combustibles

    31-DVIM33 CLEARANCES TO COMBUSTIBLES WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury or loss of life. CAUTION: This appliance is designed for use in any masonry or factory-built, wood-burning fireplace.
  • Page 12: Gas Connections

    31-DVIM33 GAS CONNECTIONS Before connecting the appliance to the gas supply line, double check that the appliance you have purchased is designed for the gas type you are using. The gas type markings are located on the certification label and also on the appliance’s gas valve.
  • Page 13: Appliance Description, Leveling The Appliance And Electrical Requirements

    ELECTRICAL CONNECTIONS The 31-DVIM33 comes complete with an variable speed fan. Do not cut or remove the grounding prong from this plug. NOTE: This appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI / NFPA 70, or the Canadian Electrical code, CSA C22.1.
  • Page 14: Glass Door Removal / If Your Glass Should Break

    Push the finger rings back in. FIGURE 1 FIGURE 2 IF YOUR GLASS BREAKS In the event your glass cracks or breaks, Archgard recommends that a new door assembly be ordered to replace the original door.  Remove door as per the instructions above.
  • Page 15: Venting Instructions

    31-DVIM33 VENTING INSTRUCTIONS WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death. The appliance must not be connected to a chimney flue serving a separate solid fuel burning appliance.
  • Page 16 31-DVIM33 VENTING INSTRUCTIONS 999-INS-TK Instructions for use with Archgard vertical termination cap. Part # 999-INS-TK Install the termination cap being sure to provide sufficient space (around and on top) so as not to impede the flow of air, both into and out of the cap. This cap is only to be used for non combustible installations. Do not recess into the top of the chim- ney.
  • Page 17: Checking Inlet/Outlet Gas Pressures, Adjusting Pilot And Convertible Pilot Orifice

    7/16” (11 mm) wrench turn a 1/4 open then push the small metal tab across to the other side of the body and retighten. Call your local Authorized Archgard Dealer to pur- 7/16” (11 mm) chase the correct fuel conversion kit for...
  • Page 18: Optional Wall Switch / Wiring Schematic

    If a wall mounted switch or a wall mounted thermostat is desired, Archgard recommends that the device be wired as shown in the diagram below. NOTE: Archgard Industries does not manufacture or sell any type of wall switch or wall thermo- stat and will not extend warranty to them...
  • Page 19 WARNING: Before starting, make certain the power supply is turned OFF. The 31-DVIM33 comes complete with a temperature activated fan and speed control installed. The heat sensor is factory set to close the circuit to the fan speed control at 110...
  • Page 20: Restrictor Plate, Surround Installation And Rocker Switch Wiring

    31-DVIM33 VENT RESTRICTOR INSTALLATION When the vent is over 18’(5.5m) a vent restrictor may be required. The installation of the restrictor will equalize the vent stack action that can cause problems with a proper fire set-up. The vent restrictor is supplied loose in the manual bag. When required, it installs onto the upper baffle in the center portion.
  • Page 21: Log Placement / Log Identification

    31-DVIM33 LOG PLACEMENT The Archgard pan burner bed and fiber logs are designed to give a realistic fire package, and created to look the same as the day they were originally installed. Care must be given when first installing the logs, and if removed for servicing, as they can be damaged or broken if not handled properly.
  • Page 22 31-DVIM33 LOG PLACEMENT... Continued Step 1. Locate Log 1 and align the holes in the bottom line up with the two locater pins. Push the top of the log up so it is against the back shelf. Push down firmly onto locater pins.
  • Page 23 31-DVIM33 LOG PLACEMENT... Continued Step 3. Locate Log 3 and align the two holes in the log with the two locater pins on the left of the burner. Push down onto locator pins as shown. LOG 3 Step 4. Locate Log 2 and align the two holes in the log with the two locater pins on the right side of the burner.
  • Page 24 31-DVIM33 LOG PLACEMENT... Continued Step 5. Locate Log 5 and align the hole in the bottom with the pin in log 3. Place the other end of the log in the saddle of log 1. LOG 5 Step 6. Locate Log 6 and align the hole in the bottom with the locater pin in log 3. Place the other end of the log on the burner and pulled forward against log 2.
  • Page 25 31-DVIM33 LOG PLACEMENT... Continued Step 7. Locate Log 4 and align the hole in the bottom with the pin on the burner surround tray. Place the other end onto log 2 as shown. LOG 4 Step 8. Place black embers around logs as shown , do not block the holes in the burner.
  • Page 26 31-DVIM33 Logs LOG 1 LOG 7 LOG 4 LOG 5 LOG 2 LOG 3 LOG 6 Item # Item Description Unit 310-634720-1 Log 1 (Left Rear) 310-634720-2 Log 2 (Right Mid) 310-634720-3 Log 3 (Left Mid) 310-634720-4 Log 4 (Right)
  • Page 27: Final Installation Check And Initial Operation

    31-DVIM33 FINAL INSTALLATION CHECK Each Archgard Gas Fireplace is checked and tested at the factory prior to being packaged and shipped to our dealers and finally installed in your home. Archgard recommends that before leaving this unit with the customer, the installer must ensure that the appliance is firing correctly and that the electrical system is in working order.
  • Page 28: Lighting Instructions On Rating Plate

    31-DVIM33 LIGHTING INSTRUCTIONS ON RATING PLATE FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire of explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by a spark •...
  • Page 29: First Fire And Lighting Instructions (Caution)

    31-DVIM33 FIRST FIRE When operated for the first few times, the appliance will emit some odor and fumes. This is due to the heat from the appliance evaporating the oils and solvents used in fabricating the appliance. Close off the room to the rest of the house and open all windows. Keep the room well ventilated, as smoke alarm may sound.
  • Page 30: Maintenance And Cleaning The Appliance

    Regularly:  Frequent cleaning of the ceramic glass is required. Archgard recommends using a good quality “gas fireplace” glass cleaner that is available at any hearth retail location. DO NOT CLEAN WHILE HOT.
  • Page 31: Servicing Under Warranty And Adjusting Primary Air

    31-DVIM33 SERVICING UNDER WARRANTY Before servicing, read the terms and conditions of the Archgard warranty at the back of the manual. Contact the authorized Archgard dealer where you purchased the appliance from and provide them with details of the problem, along with the initial installation information (from the front of this manual).
  • Page 32: Conversion Kit Instructions

    31-DVIM33 CONVERSION KIT INSTRUCTIONS IMPORTANT: This fireplace is Natural gas ready. If converting to LP gas, follow instructions below WARNING: This conversion kit shall be installed by a qualified service agency in accordance with the manufacturers instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or productions of carbon monoxide may result, causing property dam- age, personal injury or loss of life.
  • Page 33 (See Fig C) Install the LP identification label to the valve (found in kit). Affix Archgard Manufacturer’s label (part # 303-0128) in a conspicuous location. We suggest a location close to the gas control View from top of pilot head valve.
  • Page 34: Frequently Asked Questions

    Q. My fan/blower makes a “whirring” or “humming” noise. A. Your Archgard gas appliance uses a powerful fan to push heated air into your room. It is not unusual to hear a “humming” noise when your fan is running. Note: the sound will change depending on the set- ting that your fan speed control is set at.
  • Page 35: Parts

    31-DVIM33 REPLACEMENT PARTS LIST Item # Item Description Unit 200-1231 Owner’s Manual 308-0013 Valve, SIT 820 Nova, Hi/Low Natural Gas 308-0008 Piezo Igniter (Sparker) 301-0068 Orifice (Main Burner Orifice) Drill to # 33 DMS for Natural Gas Orifice (Main Burner Orifice) Drill to # 50 for LP (Propane) Gas...
  • Page 36: Replacing Convection Blower

    31-DVIM33 REPLACING CONVECTION BLOWER CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing This appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical code, CSA C22.1.
  • Page 37: Troubleshooting

    31-DVIM33 TROUBLESHOOTING Please check to make sure the instructions are followed exactly before attempting troubleshooting of the appliance. WARNING: Troubleshooting and servicing of gas and electrical devices of the appliance should only be conducted by a qualified service technician. SYMPTOM...
  • Page 38 31-DVIM33 TROUBLESHOOTING Cont... SYMPTOM ACTION The main burner does not turn 3. Check to make sure the thermostat is set high enough to turn on the on with the pilot lit. Cont... appliance. 4. Check that the remote switch or the thermostat is turned on.
  • Page 39: Notes

    31-DVIM33 NOTES...
  • Page 40: Warranty

    This Limited Warranty is made by ARCHGARD INDUSTRIES LTD., hereinafter referred to as “Archgard”. Archgard warrants to the original purchaser of an Archgard gas burning fireplace (s) that the product will be free of defects in materials and workmanship under normal use and service, for a “lifetime”.