Tester - Suzuki 2006 GSF1200AK6 Supplementary Service Manual

Table of Contents

Advertisement

TESTER

• Use the Suzuki multi-circuit tester (09900-25008).
• Use well-charged batteries in the tester.
• Be sure to set the tester to the correct testing range.
• Since the resistance may differ depending on the tester used
and the temperature, the resistance should be set to the spec-
ification.
USING THE TESTER
• Incorrectly connecting the + and - probes may cause the
inside of the tester to burnout.
• If the voltage and current are not known, make measure-
ments using the highest range.
• When measuring the resistance with the multi-circuit tester, ∞
will be shown as 10.00 MΩ and "1" flashes in the display.
• Check that no voltage is applied before making the measure-
ment. If voltage is applied the tester may be damaged.
• After using the tester, turn the power off.
" 09900-25008: Multi-circuit tester set
NOTE:
* When connecting the multi-circuit tester, use a needle pointed
probe set to the back side of the lead wire coupler and connect
the probes of tester to them.
* Use a needle pointed probe set to prevent the rubber of the
water proof coupler from damage.
" 09900-25009: Needle pointed probe set
GSF1200AK6/SAK6 ('06-MODEL)
MULTI-CIRCUIT TESTER
NEEDLE POINTED PROBE SET
17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

2006 gsf1200sak6

Table of Contents