Meat Probe Socket; Oven Door Lock Assembly - Fisher & Paykel Titan aerotech OD301US Service Manual

Table of Contents

Advertisement

(c)
Loosen two inner screws on outer door glass bracket and remove three screws
down side of bracket. (Fig. B Part 6)
(d)
Slide the outer door glass bracket clear of the hinge stanchion.
(e)
Remove door hinge retaining screw near top of stanchion. (Fig. B Part 11)
(f)
Lift door hinge and hinge stanchion enough to clear edge of door cap. (Fig. B
Part 9).
Caution: Inner edges of stainless steel door cap are very sharp.
(g)
Pull faulty door hinge out from hinge stanchion. (Fig. B Part 8)
Re-assembly
(a)
Re-fit in reverse manner.
Note: If hinge arm is unclipped use an adjustable
spanner to load up hinge spring and clip hinge arms
down.

7.22 Meat Probe Socket

Location: Near oven cavity opening on left-hand side.
Removal
(a)
Disconnect unit from power supply.
(b)
Remove meat probe socket inspection panel.
(b)
Remove socket retaining nut inside oven
cavity.
(c)
Pull meat probe socket through inspection
hole.
(d)
Cut wires to faulty socket.
(e)
Cut and strip wires from replacement socket
as shown.
(f)
Connect old wires to replacement socket
using ceramic connector blocks or high temp
wire connectors.
Re-assembly
(g)
Re-fit in reverse manner.

7.23 Oven Door Lock Assembly

Location: Behind left hand side panel.
Lock Jammed
(a)
If door lock is engaged and door cannot be removed then refer to following
procedures.
Clip
- 62 -

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents