  • Page 1: Quick Installation Guide

    IP Speed Dome Quick Installation Guide Ver. 061031 Model: CAM-6200/6220...
  • Page 2: Copyright

    Copyright This manual is the intellectual property of ACTi and is protected by copyright. All rights are reserved. No part of this document maybe reproduced or transmitted for any purpose by any means including electronic or mechanical without the official written permission from ACTi.
  • Page 3: Fcc/Ce Regulation

    and manuals without prior notice. FCC/CE Regulation NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
  • Page 4: Table Of Contents

    Table of Contents PRECAUTIONS....................0-1 Copyright .............................0-1 Trademarks ..........................0-1 Liability............................0-1 FCC/CE Regulation ........................0-2 Installation ......................1-1 Connections ......................1-1 1.1.1 Indoor connections ......................1-1 1.1.2 Outdoor connections......................1-2 Speed dome setup ....................1-3 1.2.1 Setup camera ID, baud rate and protocol...............1-3 Indoor installation....................1-5 1.3.1 Punching a hole in the ceiling..................1-5 1.3.2...
  • Page 5 AP (Streaming Activator) setup............... 2-15 2.2.1 Open Streaming Activator...................2-15 2.2.2 Click Setup........................2-15 2.2.3 Click PTZ setup......................2-16 2.2.4 Click PTZ setup and follow the picture below to setup..........2-17 2.2.5 Press the Apply button and reconnect to the IP speed dome........2-17 2.2.6 PTZ function will work perfectly now.................2-17 Appendix......................
  • Page 6: Installation

    Installation 1.1 Connections Indoor IP speed dome connection is different from the outdoor IP speed dome. Follow the description below to connect to respective apparatus. 1.1.1 Indoor connections 1. Analog Video-out connector Connect it to the video-in port of respective apparatus. The signal is 75Ω Composite Video Signal.
  • Page 7: Outdoor Connections

    speed of local network segment (10Base-T/100Base-TX Ethernet). The WAN port is for FTTH and connects to an xDSL or cable modem. 1.1.2 Outdoor connections 1. Analog Video-out connector Connect it to the video-in port of respective apparatus. The signal is 75Ω Composite Video Signal.
  • Page 8: Speed Dome Setup

    1.2 Speed dome setup Follow the description below setup IP speed dome’s hardware camera ID, baud rate and protocol. AP (Streaming Video platform setup Speed dome setup Activator) setup Camera ID, baud rate and protocol setting in these 3 item should be the same for PTZ control function to work.
  • Page 9 Protocol and baud rate switch SW10 PELCO D-2400 PELCO P-4800 PELCO P-9600 (Recommended) EYEVIEW Camera ID address setting Please refer to the Appendix. A “Camera hardware ID setup”...
  • Page 10: Indoor Installation

    1.3 Indoor installation 1.3.1 Punching a hole in the ceiling Remove the target ceiling first, then attach the hole-sticker supplied with the camera to the ceiling and make the desired hole accordingly with a proper tool. 1.3.2 Take out the camera 1.3.3 Fit the upper casing into the ceiling as shown below.
  • Page 11: Once Complete The Above Steps, Place The Complete Camera (Except The Dome Cover)

    1.3.5 Once complete the above steps, place the complete camera (except the dome cover) back to the ceiling as shown below.
  • Page 12: Outdoor H/W Installation Procedures

    1.4 Outdoor H/W installation procedures There are 4 kinds of outdoor application. And each of them requires two steps to install the outdoor IP speed dome. Please refer to the picture below to understand each application type. Then follow the procedure below to install it. 1.4.1 Understand Outdoor applications Outdoor Wall mount...
  • Page 13 Outdoor Corner mount Outdoor Housing outdoor Wall mount outdoor Corner bracket Outdoor Pole mount Outdoor Housing outdoor Wall mount outdoor Pole bracket...
  • Page 14: Install The Mount

    1.4.2 Install the mount The mounting wall must be strong enough for holding the camera. Minimum loading capacity should be at least 35 kg or above, for prevention of fall and personal injury. Mark the 4 mounting hole centers according to the mount base plate, as shown below: 170mm 200mm...
  • Page 15: Configuration

    Configuration 2.1 Network video platform (Web configurator) setup 2.1.1 Make sure network environment Default IP of IP Speed Dome is 192.168.0.100. Please make sure IP Speed Dome and your PC is on the same network segment before running the installation. Please set the settings as below.
  • Page 16: Open Internet Explorer With Ip Address

    2.1.2 Open Internet Explorer with IP address NOTE: If your web browser is earlier than IE6, then download IE6 is recommended. NOTE: The IP high speed dome default IP address is set to 192.168.0.100 2.1.3 Login with default administrator’s account & password NOTE: Default administrator account is set to Admin, password is set to...
  • Page 17: Preview The Video

    2.1.4 Preview the video NOTE: In your Client PC, please make sure the setting of Network Connections Type is set to Auto Negotation, since IP high speed dome follows MII standard. Otherwise, you might not see the live image. 2-12...
  • Page 18: Set The New Ip Address

    2.1.5 Set the new IP address Host Name : Enter in the domain name, Default Host Name is ACTi. Language : Language setting for Web Configurator after Save Reboot. Default setting is English. IP Address : The IP address of the LAN interface. The default IP address is 192.168.0.100.
  • Page 19: Check Default Video Setting

    2.1.6 Check default video setting The streaming type [Version 1.0] – without audio function The streaming type [Version 2.0] – with audio function NOTE: Please make sure the TV Input (NTSC / PAL) is meet your requirement, and click button. 2.1.7 Click Save Reboot to restore all settings and please wait about 30 seconds for system reboot.
  • Page 20: Ap (Streaming Activator) Setup

    2.2 AP (Streaming Activator) setup Please follow the procedures below to setup the PTZ function of the Streaming Activator. Wrong settings will cause CAM-62xx SERIES PTZ function doesn’t work. 2.2.1 Open Streaming Activator. 2.2.2 Click Setup. This is an example setting in 1.36.02. version, other software version please refer to this setting as well.
  • Page 21: Click Ptz Setup

    2.2.3 Click PTZ setup. 2-16...
  • Page 22: Click Ptz Setup And Follow The Picture Below To Setup

    2.2.4 Click PTZ setup and follow the picture below to setup. 2.2.5 Press the Apply button and reconnect to the IP speed dome. 2.2.6 PTZ function will work perfectly now. 2-17...
  • Page 23: Appendix

    Appendix 3.1 Camera ID setup Symbol “○” in the following tables denote setting “ON “ 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 3-18...
  • Page 24 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 3-19...
  • Page 25 1 2 3 4 5 6 7 8 3-20...