Getting Started PACKAGE CONTENTS CAM-6500 series Warranty Card Software CD Power & A/V Cable LAN/WAN Cable Alarm Cable 5.4” Transparent Cover Decoration Ring / Fixing Plate Power Adaptor (Option)
1.2 PHYSICAL DESCRIPTION Indoor High Speed Dome Bottom 1. Reset Button Step 1: Switch off IP device by disconnecting the power cable Step 2: Press and continue to hold the Reset Button. Reconnect the power cable while continuing to hold the reset button. Step 3: Keep holding the reset button depressed around 6 seconds, release the reset button.
Page 4
number respectively. For instance, if the speed dome ID is 123, the ID switch should be set as below: centesimal decimal single digit NOTE: No two speed domes should be given the same ID, or communication conflict may occur. NOTE: The number “0”...
Page 5
6. 22 Pin Connector A 50cm data cable (shown as the figure below) is shipped with IP high speed dome. Please find it in the accessory bag. The 22-pin connector definition is listed as below. Cable AC 24-1/DC GND 20AWG Alarm Pin (Not wired) AC 24-2/DC 12(+) 20AWG...
Wiring Indication PIN NAME DESCRIPTION of Power Adapter AC24V AC 24V of Power Input Brown E-GND E-Ground Pin of Power Input Green/Yellow AC24V AC 24V of Power Input Blue Power Adpater 1.3 Cable Wiring Cable Wiring and Connection Users may need to do cable wiring when connecting alarm input and output devices. The table follows will illustrate the way to wire cords into the connector housing (shown in the figures below).
Page 7
Insert the terminal into the pin holes on the connector housing, with the hook outward, as indicated in the figure. To unlock the terminal, press the hook, as indicated in the figure, with a proper tool and pull it out gently. Alarm Cable Wiring The alarm pins are serviceable for connecting alarm input and output devices, such as alarm sensors, sirens or flashing lights with the surveillance system.
ALM-8 ALM GND 1.4 Mounting the IP High Speed Dome Generally, there are three kinds of ceiling mounting methods: surface mount, in-ceiling mount, and mounting with straight tube. The surface mounting kit is shipped with IP high speed dome. For more detailed information, please refer to Appendix A.
Quick Tour This section guides you with a quick tour on IP high speed dome. 2.1 Configure the IP High Speed Dome 2.1.1 Make sure network environment Default IP of IP high speed dome is 192.168.0.100. Please make sure IP high speed dome and your PC are on the same network segment before running the installation.
Page 10
2.1.2 Open Internet Explorer with IP address NOTE: If your web browser is earlier than IE6, then download IE6 is recommended. NOTE: The IP high speed dome default IP address is set to 192.168.0.100 2.1.3 Login with default administrator’s account & password NOTE: Default administrator account is set to Admin, password is set to 123456, and click...
Page 11
2.1.4 Preview the video NOTE: In your Client PC, please make sure the setting of Network Connections Type is set to Auto Negotation, since IP high speed dome follows MII standard. Otherwise, you might not see the live image.
Page 12
2.15 Set the new IP address *Host Name : Enter in the domain name, Default Host Name is ACTi. *Language : Language setting for Web Configurator after Save Reboot. Default setting is English. *IP Address : The IP address of the LAN interface. The default IP address is 192.168.0.100.
Page 13
2.1.6 Check Default Video Setting The streaming type [Version 1.0] – without audio function The streaming type [Version 2.0] – with audio function NOTE: Please make sure the TV Input (NTSC / PAL) is meet your requirement, and click button. 2.1.7 Click Save Reboot to restore all settings and please wait about 30 seconds for system reboot.