Item
URL
Username
Password
(3) Enter Maintenance Mode.
See Appendix B.1.1, "Enabling maintenance Mode (APP0201010)".
(4) Prepare disk units which added SAS array controller cards and flash backup units into.
(5) Remove the DU cover.
See Appendix C.10.2,"Removing the DU (APP0310020)".
(6) Installing the flash backup unit, if there is a flash backup unit.
See Appendix C.14.1, "Installing the FBU (APP0314010)." and Appendix C.14.2, "Installing TFM
module (APP0314020)".
(7) Install SAS array controller cards into the DU.
See Appendix C.15, "Installing the SAS array controller card (DU) (APP0315000)".
(8) Reinstall the DU cover.
See Appendix C.10.1, "Installing the DU (APP0310010)".
(9) If a HDD/SSD is added at the same time, verify the operations to the procedure in chapter 5.
Adding an Internal Hard Disk Drive (HDD) / Internal Solid State Drive (SET0500000).
(10)Remove the dummy DU.
(11) Install the DU.
See Appendix C.10.1, "Installing the DU (APP0310010)".
(12) Confirm that the Alarm LEDs are not on.
(13) Change Maintenance Mode disabled. See Appendix B.1.2," Disabling maintenance mode
(APP0201020)".
Table 6.2.2
Setting values
http://<Maintenance IP Address>:<http port#> or
https://<Maintenance IP Address>:<https port#>
This depends on the system configuration.
http port#:Default(8081)
https port#:Default(432)
Account username
Account password