CONTROLS AND SETTINGS

All welder/generator controls are located on the
FIGURE B.1 and B.1a – OUTPUT PANEL CONTROLS
FIGURE B.1
9
10
HOURS
50
AMPS
AMPS
75
AMPS
AMPS
MAX
100
AMPS
AMPS
IDLER
125
AMPS
AMPS
WARNING
WARNING
ELECTRODE SELECTION GUIDE
ELECTRODE SELECTION GUIDE
+
-
2
3
(For Codes 10158, 10160)
1. CURRENT CONTROL DIAL
2. ELECTRODE SELECTION GUIDE
3. WELD POSITIVE OUTPUT TERMINAL
4. WELD NEGATIVE OUTPUT TERMINAL
5. GROUND STUD
6. 20 AMP CIRCUIT BREAKERS (2)
7. 20 AMP, 230 VOLT RECEPTACLE
8. 20 AMP, 115 VOLT DUPLEX RECEPTACLE
9. HOUR METER
10. IDLER SWITCH
WELDER/GENERATOR CONTROLS
See Figure B.1 and B.1a for the location of the following
features:
1. CURRENT CONTROL DIAL: Adjusts continuous
current output. The amperages on the dial correspond
to the approximate amperages needed for specific
Lincoln welding electrodes.
2. ELECTRODE
SELECTION
recommended electrode type, size, and welder output
setting based on the thickness of the work.
3.
WELD POSITIVE OUTPUT TERMINAL Provides the
connection point for either the electrode holder or the
work cable. (Because the Weldanpower 125 is a DC
output machine, either output terminal can be used for
either cable.)
4. WELD NEGATIVE OUTPUT TERMINAL Provides the
connection point for either the electrode holder or the
work cable. (Because the Weldanpower 125 is a DC
output machine, either output terminal can be used for
either cable.)
5. GROUND STUD: Provides a connection point for
connecting the machine case to earth ground for the
safest grounding procedure.
OPERATION
1
8
WELDANPOWER 125
WELDANPOWER 125
7
5
5
4
6
GUIDE:
Provides
Output Control Panel. Gasoline engine controls are
mounted on the engine. See Figure B.1, B.1a and the
figures in the engine operation section.
9
HOURS
WARNING
ELECTRODE SELECTION GUIDE
+
2
3
(For Codes 11183, 11406)
1. CURRENT CONTROL DIAL
2. ELECTRODE SELECTION GUIDE
3. WELD POSITIVE OUTPUT TERMINAL
4. WELD NEGATIVE OUTPUT TERMINAL
5. GROUND STUD
6. 20 AMP CIRCUIT BREAKERS (2)
7. 20 AMP, 240 VOLT RECEPTACLE
8. 20 AMP, 1120 VOLT DUPLEX RECEPTACLE
9. HOUR METER
(For Codes 10158, 10160)
6. CIRCUIT BREAKERS (2): Provide separate
overload current protection for the 115 volt and
230 volt receptacles.
7. 230 VOLT RECEPTACLE: Connection point for
supplying 230 volt power to operate one
electrical device.
8. 115 VOLT DUPLEX RECEPTACLE: Connection
point for supplying 115 volt power to operate one
or two electrical devices.
9. HOUR METER: Records the time that the engine
has run for maintenance purposes.
10. IDLER SWITCH: Allows for setting the idle speed
of the engine for FAST IDLE or AUTOMATIC
IDLE.
(For Codes 11183, 11406)
6. CIRCUIT BREAKERS (2): Provide separate overload
current protection for the 120 volt and 240 volt
receptacles.
7. 240 VOLT RECEPTACLE: Connection point for
supplying 240 volt power to operate one electrical
device.
8. 120 VOLT DUPLEX RECEPTACLE: Connection point
for supplying 120 volt power to operate one or two
electrical devices.
9. HOUR METER: Records the time that the engine has
run for maintenance purposes.
12
FIGURE B.1a
1
50
AMPS
75
AMPS
MAX
100
AMPS
125
AMPS
WELDANPOWER 125
-
5
5
4
6
WELDANPOWER 125
8
7