Command bit dec hex Function and description
S50=
S56=
S61=
bit dec hex
3
S64=
S79=
bit dec hex Bit mapped register.
0
0
2
3
0-
Inactivity timer for RS-232
255
Port. Each unit = 10 sec. 000
disables.
0-
0-
Hook flash detect time for
255
FF
Analog Adapter (POTS port);
units 10ms.
*0 0
MP data sent in rotate mode.
1
1
MP data sent in split mode.
0-
0-
Security callback timer in unit
255
FF
of 1 second.
*0 0
Ignore POTS port 1 global
incoming call when port 1 is
busy.
1
1
Discard POTS port 1 global
incoming call when port 1 is
busy (Sending RELEASE
COMPLETE).
*0 0
Ignore POTS port 2 global
incoming call when port 1 is
busy.
2
2
Discard POTS port 2 global
incoming call when port 1 is
busy (Sending RELEASE
COMPLETE).
0
0
POTS 1 call-waiting/multiple-
answer disabled.
*4 4
POTS 1 call-waiting/multiple-
answer enabled.
0
0
POTS 2 call-waiting/multiple-
answer disabled.
*8 8
POTS 2 call-waiting/multiple-
answer enabled.
Ref.
+000
+050
+005
+000
135