Electrical Installation - Regency Horizon HZ42STEPV Owners & Installation Manual

Table of Contents

Advertisement

THIS INSTALLATION SHOULD ONLY BE CARRIED
OUT BY A QUALIFIED AND LICENSED ELECTRICIAN
Important: 120 Volt AC power is required for the power vent
installation.
The receptacle box will be installed on the lower left corner
of the unit and will need to be wired by a qualifi ed electrician
prior to the power vent installation. The neutral (wider) slot
of the polarized receptacle should be at the top. See wiring
diagram in the instruction manual
Caution: Label all wires prior to disconnection when
servicing controls.
Wiring errors can cause improper and dangerous
Note: For ease of installation, the electrical installation must be completed
prior to adding any fi nishing materials.
1) Remove faceplate, inner door frame and glass door - refer to
instructions in this manual.
2) Remove control board located on the lower right side of the unit,by
sliding board out as shown below.
3) Locate wiring harness from Power Vent Module - shown below.
Power Vent Module
Regency Horizon™ HZ42STEPV Gas Fireplace

ELECTRICAL INSTALLATION

WARNING
operation.
Wiring harness from
Power Vent Module
4) Remove access panel - located on the outer right side of the unit, by
removing 4 screws in locations shown below.
5) Loosen 2 screws - one on either side of the electrical box. Slide box up
and push box back to release.
6) Manoeuvre and angle electrical box to remove from the base of the unit.
7) Install strain relief grommets into opening as shown below.
INSTALLATION
Access panel
Electrical
Box
(Right side of
Unit)
Strain Relief
23