Optional Fan Wiring Diagram; Without Proflame Gtmf System - Regency Horizon HZ42STEPV Owners & Installation Manual

Table of Contents

Advertisement

Lockwasher
Star washer
(for mobile home)
Nut
Fan
ground wire
Electrical Connection Alternative Scheme "A",
Power at Stove
Wall Junction Box
~
Wire Nuts
14 AWG wire
*Wire Clamp
*Receptacle Box
inside stove
*Receptacle
(dedicated use
by stove fan only)
Copper Ground
120 Volts
White (Neutral)
60 Hz
Black (Hot)
14 AWG wire
Regency Horizon™ HZ42STEPV Gas Fireplace

OPTIONAL FAN WIRING DIAGRAM

WITHOUT PROFLAME GTMF SYSTEM

#8 Ground Lug
*Speed Control
Switch with
lead wires
(Regency)
120 Volts
60 Hz Copper Ground
Wire Nuts
* = supplied with fan kit
Other parts are to be supplied
by electrician or installer
Green (Ground)
120 VAC
White (Neutral)
60HZ
Black (Live)
(*by others)
(*by others)
Rotary Speed
Control
ON
OFF
Black
Electrical Connection Alternative Scheme "B",
Power at Switch
Wall Junction Box
~
Black (Hot)
White (Neutral)
Wire
Caution: Ensure that the wires do not touch any
hot surfaces and are away from sharp edges.
INSTALLATION
Fan
White
Thermodisc
*Speed Control
Switch with lead wires
Wire Nuts
Black
White
14 AWG wire
Ground
*Wire Clamp
*Receptacle Box
inside stove
*Receptacle
(dedicated use
by unit fan only)
Ground for
mobile home
Fan
(*Supplied
by others
- install
according to
local code)
29

Advertisement

Table of Contents
loading