INSTALLATION
8) Unravel BX cable to reveal wires - install wire protector where the metal
of the BX cable meets the wire.
9) Feed wires from the BX cable through into the box.
10) Tighten up the strain relief grommets on the outside of the box as
shown below.
24
11) Secure the ground wires from each wire bundle (BX cable + power
vent) to the box in the location shown below.
Wire protector
Ground
12) Connect all like colored wires - blue to blue, red to red, white to white
and black to black. Finish wire ends with marettes as shown below.
13) Install the cover on the electrical junction box-secure with 2 screws.
14) Reverse steps 6-1 to complete installation.
15) Plug in Power Vent Module to outlet located on the lower left base of
the unit.