8 ) Reattach the plate to the inside of the Power Vent out frame with 2
screws from step 3.
9) Feed the BX cable through the opening in the power vent terminal -
located in the lower left corner as shown below.
10) Secure the terminal to the outer frame with 4 screws - screw locations
shown below.
11) From the wire bundle (from BX cable) secure the copper ground to the
ground lug on the right side.
Important: Ground must be wrapped under star washer - prior to
tightening.
Regency Horizon™ HZ42STEPV Gas Fireplace
12) Tighten bolt to secure ground wire.
13) Connect all like colored wires - red to red, blue to blue, black to black
and white to white. Place marettes on all paired wire ends (supplied
with kit)
14) Place cable tie guides in holes located on the base of the terminal.
Feed cable tie through the guide.
15) Tie down all wires with cable tie - away from the
edge of the terminal base and fan blade.
Star washer
INSTALLATION
Cable tie guide
Cable tie
Marettes