INSTALLATION
ELECTRICAL CONNECTIONS SHOULD ONLY BE
CARRIED OUT BY A QUALIFIED AND LICENSED
ELECTRICIAN
Note: Optional 5 wire BX cable comes in 20' or 60' lengths as required.
Wires are color coded for ease of installation.
1) Frame in opening for the Power Vent Terminal by fi rst determining the
correct height - frame in an 11-3/4" x 11-3/4" opening.
11-3/4"
Determine
the correct
height
2) Feed the BX cable through the fi restop - ensure protective grommet is in
place before feeding the cable through.
3) Install the Power Vent outer frame with 4 screws - screw locations
shown below.
Important: Orient the frame so the BX cable will pass through in the lower
left corner.
20
POWER VENT TERMINAL INSTALLATION
WARNING
11-3/4"
Firestop
Protective grommet
4) Remove the plate from the bottom right corner of the frame by removing
2 screws from the inside of the frame.
5) Install a strain relief grommet through the plate as shown below.
6) Unravel the BX cable - to expose approx. 7" of wire. Install a wire
protector where the metal of the BX cable and the wire meet.
7 ) Feed a length of BX cable through - (approx. 18") the plate and tighten
the strain relief grommet to the plate.
Regency Horizon™ HZ42STEPV Gas Fireplace
Strain Relief
Wire protector