Checking The Burner Gasket And Burner Gauze Assembly - Viessmann VITODENS 100-W Installation And Service Instructions Manual

Wall mounted gas condensing boiler natural gas and lpg version
Hide thumbs Also See for VITODENS 100-W:
Table of Contents

Advertisement

Further details regarding the individual steps
6. Undo four screws F and remove the
burner.

Checking the burner gasket and burner gauze assembly

Check burner gasket A for damage and
replace if required.
B
1. Remove electrode B.
2. Undo the two Torx screws and
remove thermal insulating ring C.
Commissioning, inspection, maintenance
!
Replace the burner gauze assembly if it
is damaged.
E
D
2x
3. Undo the two Torx screws and
remove burner gauze assembly D
with gasket E.
(cont.)
Please note
Prevent damage.
Never rest the burner on the
burner gauze assembly.
C
A
39