Repairs
(cont.)
Checking or replacing the plate heat exchanger (gas condensing
combi boiler)
D
E Heating water flow
F Heating water return
1. Shut off and drain the boiler on the
heating water and the DHW side.
2. Pivot down control unit.
3. Push servomotor A slightly
upwards.
D
E
H
C
G Cold water
H DHW
4. Turn adaptor B with servomotor A
1/8 of a turn anticlockwise and
remove.
Troubleshooting
F
G
A
B
59