Viessmann VITODENS 100-W Installation And Service Instructions Manual

Viessmann VITODENS 100-W Installation And Service Instructions Manual

Gas fired wall mounted condensing boiler
Hide thumbs Also See for VITODENS 100-W:
Table of Contents

Advertisement

5592 827 GB
11/2007

Advertisement

Table of Contents
loading

Summary of Contents for Viessmann VITODENS 100-W

  • Page 1 5592 827 GB 11/2007...
  • Page 6: Technical Specification

    Technical Specification General Specifications and Performance Data. Vitodens 100-W WB1A Appliance Combi 24 kW Combi 30 kW System 24 kW Mode Unit Rated central heating output Tf/Tr 50/30 ºC (condensing) 8 to 24 8 to 30 8 to 24 Tf/Tr 80/60 ºC (non condensing) 7 .3 to 21.8...
  • Page 13 Preparing for Installation (cont.) Plume kit installation instructions The plume kit enables the relocation of the flue outlet of a standard horizontal flue system to another position and is available as an optional extra, please contact your supplier for further information. Routing options Plume kit standard delivery 2m max Plume kit standard delivery...
  • Page 14 Preparing for Installation (cont.) Flue kit installation instructions 1. Start 2. Remove the nozzle of the wall terminal with a tool (screwdriver) 3. Mount the 90º. Its main advantage is that you can install this bend into the necessary angle by simply turning the outlet.
  • Page 15 Preparing for Installation (cont.) Flue kit installation instructions 4. Connect the pipe to 5. Brace the pipe to the bend. the bend. 6. Continue step 4 and 5 until the desired height is reached. 7 . Connect the 87º bend with bird mesh to the last mounted pipe.
  • Page 16 Preparing for Installation (cont.) Fitting the plume kit (cont.) 6. Fit the flue pipes and bends in accordance with the selected installation method and secure with the fixing clamps supplied. 7 . Insert the rodent protection grill into the uppermost bend. Ventilation Requirements •...
  • Page 17: Hydraulic Connections

    Hydraulic connections Heating System (typical system designs) • The Vitodens 100-W is designed for • A sealed system must only be filled by a connection to sealed central heating competent person. water systems only. Combination boiler Note The boiler incorporates an internal bypass to ensure adequate water flow.
  • Page 21: Installation Requirements

    Preparing for Installation (cont.) Installation requirements Statutory requirements The appliance is suitable only for installation in GB and IE and should be installed in accordance with the rules in force. In GB, a corgi Registered Installer must carry out the installation.
  • Page 31 System boiler only Y-plan and S-plan system...
  • Page 32 System boiler only Y-plan system...
  • Page 33 System boiler only Y-plan system (cont.)
  • Page 34 System boiler only S-plan system...
  • Page 35 System boiler only S-plan system (cont.)
  • Page 37 The flow rate may vary by approx. 10%. If necessary, a pressure reading valve must be fitted to the main supply before the DHW inlet connection.

Table of Contents