SECTION 10 –
SLIDEOUT ROOMS AND LEVELING
(9) - HALL POWER SHORT TO
GROUND. Power to encoder has been
shorted to ground. This is usually a wiring
problem.
NOTE: When an error code is present, the
slideout control panel needs to be reset.
Operating the Extend/Retract switch will
reset the slideout control panel. Operate
the Extend/Retract switch again for
normal operation.
Manual Override
In the event that the slideout room fails to
retract and manual operation is required:
Locate the slideout control panel (located in
driver side compartment).
Press the Mode button 6 times, quickly. Press
a 7th time and hold for approximately 5
seconds.
Red and green LED lights will begin to flash,
confirming the override mode.
Release Mode button.
Use the slideout control switch (located inside
the coach) to retract the room.
NOTE: If slideout room fails to retract using the
Manual Override method, see "Slideout
Emergency Retraction" elsewhere in this
section.
Further Information
See the slideout room operating guide
included in your InfoCase for further instructions
and troubleshooting information.
SLIDEOUT EMERGENCY
RETRACTION (POWER GEAR
-If Equipped
If the slideout mechanism is malfunctioning
and the room will not retract using the interior
control switch, you may need to access the
motor/gear assembly and manually crank the
room in to the travel position.
10-8
Your coach may be equipped with one or two
motor/gearbox units (depending on model),
which is located beneath the slideout room rail
(or beneath each of the slideout room rails, if
equipped with two motor/gearbox units).
Crank-In Procedure
1. Disengage the motor brake, which appears as
a flat "square" protrusion on the protective
boot at the end of the motor. Move the brake
lever slightly - about 1/8 turn counter-
clockwise, or to left when facing end of motor
(repeat for motor at other end of room, if
equipped).
2. Disconnect the motor power lead from the
wiring harness (repeat for motor at other end
of room, if equipped).
3. Use a 3/4" socket and ratchet wrench on the
motor gearbox shaft to crank the room in to
the travel position.
2) Disconnect
motor power lead
from wiring harness
Slideout Motor/Gear Assembly
(Located beneath end of slideout room rail)
)
®
* Shown with slideout room extended
NOTE: If equipped with two motor/gearbox
units, crank both sides of the room
alternately and equally to avoid wedging
the room.
If help is available, a second person
(with a duplicate socket and ratchet)
cranking the other end simultaneously
will greatly speed up the process.
3) Use 3/4"socket on gearbox
shaft to crank room in
1) Lift tab inside
protrusion on boot to
disengage motor brake
-Typical View