1.4520.596 – MIC5 IPE Prim Short Circuit Cyl 7
Yellow alarm. Initiated by MIC5.
Cause
Short circuit in primary circuit of
cylinder 7 in firing order.
1.4520.597 – MIC5 IPE Prim Short Circuit Cyl 8
Yellow alarm. Initiated by MIC5.
Cause
Short circuit in primary circuit of
cylinder 8 in firing order.
1.4520.598 – MIC5 IPE Prim Short Circuit Cyl 9
Yellow alarm. Initiated by MIC5.
Cause
Short circuit in primary circuit of
cylinder 9 in firing order.
1.4520.599 – MIC5 IPE Prim Short Circuit Cyl 10
Yellow alarm. Initiated by MIC5.
Cause
Short circuit in primary circuit of
cylinder 10 in firing order.
1.4520.600 – MIC5 IPE Prim Short Circuit Cyl 11
Yellow alarm. Initiated by MIC5.
Cause
Short circuit in primary circuit of
cylinder 11 in firing order.
1.4520.601 – MIC5 IPE Prim Short Circuit Cyl 12
Yellow alarm. Initiated by MIC5.
Cause
Short circuit in primary circuit of
cylinder 12 in firing order.
1.4520.602 – MIC5 IPE Prim Short Circuit Cyl 13
Yellow alarm. Initiated by MIC5.
Cause
Short circuit in primary circuit of
cylinder 13 in firing order.
Corrective action
1. Check cabling to ignition coil.
2. Check ignition coil.
Corrective action
1. Check cabling to ignition coil.
2. Check ignition coil.
Corrective action
1. Check cabling to ignition coil.
2. Check ignition coil.
Corrective action
1. Check cabling to ignition coil.
2. Check ignition coil.
Corrective action
1. Check cabling to ignition coil.
2. Check ignition coil.
Corrective action
1. Check cabling to ignition coil.
2. Check ignition coil.
Corrective action
1. Check cabling to ignition coil.
2. Check ignition coil.
MS15027/00E 2013-10 | Troubleshooting | 85