MTU 12 V 4000 Lx4 Operating Instructions Manual page 106

Gas engine
Table of Contents

Advertisement

1.4550.036 – A - Temperature derating active
Yellow alarm. Initiated by ProAct A-Bank.
Cause
The internal temperature is
higher than the limit.
1.4550.037 – A - Temperature above 120 °C
Red alarm. Initiated by ProAct A-Bank.
Cause
The internal temperature is
higher than the limit.
1.4550.038 – A - Loss of Position Demand
Red alarm. Initiated by ProAct A-Bank.
Cause
Position demand is missing or
out of range
1.4550.039 – A - Demand Tracking Fault
Yellow alarm. Initiated by ProAct A-Bank.
Cause
ProAct setting is not correct.
1.4550.040 – A - Analog Position Demand Failed
Yellow alarm. Initiated by ProAct A-Bank.
Cause
ProAct setting is not correct.
1.4550.041 – A - PWM Position Demand Failed
Yellow alarm. Initiated by ProAct A-Bank.
Cause
ProAct setting is not correct.
1.4550.042 – A - CAN Position Demand Failed
Red alarm. Initiated by ProAct A-Bank.
Cause
Position demand not received or
received too late
106 | Troubleshooting | MS15027/00E 2013-10
Corrective action
1. Check room temperature. Restart ProAct.
2. Restart ProAct.
Corrective action
1. Check room temperature. Restart ProAct.
2. Restart ProAct.
Corrective action
1. Check setting.
2. Check cabling.
Corrective action
u Check setting.
Corrective action
u Check setting.
Corrective action
u Check setting.
Corrective action
u Check cabling and setting.