MTU 12 V 4000 Lx4 Operating Instructions Manual page 162

Gas engine
Table of Contents

Advertisement

Measuring valve depth
1.
Check TDC position of piston in cylinder A1:
• If the rocker arms are unloaded on cylinder A1, the piston is in firing TDC.
• If the rocker arms are under load on cylinder A1, the piston is in overlap TDC.
2.
Measure valve depth for each valve in two crankshaft positions (firing TDC and overlap TDC for cylinder
A1) according to the diagram. Diagram (→ Page 165).
3.
Release adjusting screw (1) and remove
valve bridge. Do not remove rocker arm (2)!
4.
Measure distance between valve stem end
and cylinder head top at the spark plug
bore with depth gauge (see figure).
• The specified value for a new cylinder
head: 93.8 mm.
• Admissible wear: 3 mm.
• If the measured value is > 96.8 mm, re-
place the relevant cylinder head ahead
of schedule.
5.
Install valve bridge.
6.
Adjust valve clearance (→ Page 165).
Final steps
1.
Remove barring device (→ Page 147).
2.
Check condition of O-rings at the sleeves, replace if damaged.
162 | Task Description | MS15027/00E 2013-10

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

16 v 4000 lx4