582 – AL Emergency Stop Failure
Emergency stop command was not executed
Flashing pre-alarm and alarm
Cause
Engine speed does not come to
a standstill within a configurable
period.
584 – AL CAN Start clearance failed
Yellow alarm; warning
Cause
Yellow alarm; warning; CAN
object Start clearance was not
received within the expected
time period.
586 – LO P-Oil Refill Pump
Oil pressure in refill pump is too low - limit value 1
Yellow alarm; warning
Cause
Oil level in oil refill tank too low.
588 – SD P-Oil Refill Pump
Signal error, refill pump oil pressure sensor
Yellow alarm; warning
Cause
Pressure sensor defective.
Short circuit or wire break.
593 – AL T-Lube Oil in Oil Pan too Low
Lube oil temperature in oil pan is too low.
Cause
Preheating time is insufficient.
ZKP-Number: 1.1005.006
Corrective action
u Contact Service.
Corrective action
u Contact Service.
ZKP-Number: 2.0159.911
Corrective action
1. Check oil level, top up as necessary (→ Page 218).
2. Contact Service.
ZKP-Number: 1.0159.910
Corrective action
1. Check sensor and wiring, replace as necessary (→ Page 265).
2. Contact Service.
ZKP-Number: 2.1090.929
Corrective action
1. Extend preheating period.
2. Contact Service.
MS150068/01E 2014-01 | Troubleshooting | 157