Power Up

Common Start-Up Problems

Loss of Clock – Panel needs to have
time and date set. To do this press
[*][6][Master Code][1], then enter
time/date as: HH:MM/MM/DD/YY.
TLM – Panel has no phone line
connected. To cure this fault, enter
programming [*][8][Engineer Code]
and enter section 015. Turn off option
7.
Zone Fault/Tamper – Incorrect zone
supervision selected. Enter program-
ming [*][8][Engineer Code] and enter
section 013. Select correct options
from 1 and 2.
14
Common Start-Up Problems
[*][5] Programming Access Codes
Press [*][5][Master Code]. The keypad
will flash the program light and turn
on the zone light for any codes
already programmed.
Enter the two-digit user number for
the code you want to program. The
corresponding zone light will flash.
Enter the four-digit code. The zone
light will then turn on steady. Do not
use [*] or [#] in user codes. Push the
[#] when you have finished.
To enable the code, press [*][5][Mas-
ter Code][9], and make sure that light
1 is turned on.
To allow the user to bypass zones,
turn on light 3. When you are finished,
push [#].
[*][6] User Functions
Press [*][6][Master Code]
[*] to view event buffer;
[1] to set the time and date;
[4] for system test;
[5] to enable DLS window.
[*][7] Output Functions
[*][7][Access Code] to activate Utility
Output.
[*][7][2] to activate smoke detector or
shock sensor reset.
[*] Commands
[*] Commands
19