DSC New Classic PC585 Instruction Manual
Hide thumbs Also See for New Classic PC585:

Advertisement

• W A R N I N G •
This manual contains information on limitations regarding product use and function and
information on the limitations as to liability of the manufacturer. The entire manual
should be carefully read.
Instruction
Manual
Software Version 2.4ZD

Advertisement

Table of Contents
loading

Summary of Contents for DSC New Classic PC585

  • Page 1 • W A R N I N G • This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. The entire manual should be carefully read. Instruction Manual ™...
  • Page 2: Note To Installers

    WARNING Smoke Detectors Please Read Car Please Read Car Please Read Carefully efully efully efully Please Read Car Please Read Car efully Smoke detectors that are a part of this system may not properly alert occupants of a fire for a number of reasons, some of which follow. The smoke detectors may Note to Installers have been improperly installed or positioned.
  • Page 3: About Your Security System

    General System Operation Your security system is made up of a DSC control panel, one or more keypads and various sensors and detectors. The control panel will be mounted out of the way in a utility closet or in a basement. The metal cabinet contains the system electronics, fuses and stand-by battery.
  • Page 4: System Information

    System Information Fill out the following information for future reference and store this manual in a safe place. Access Codes Your Master Code is: __________________________________________ Additional Access Codes: 01 __________________ 09 ____________________ 17 ____________________ 25 ________________ 02 __________________ 10 ____________________ 18 ____________________ 26 ________________ 03 __________________...
  • Page 5 ___________________________________________ _____________________________________ ___________________________________________ _____________________________________ ___________________________________________ _____________________________________ ___________________________________________ _____________________________________ ___________________________________________ _____________________________________ ___________________________________________ _____________________________________ ___________________________________________ _____________________________________ ___________________________________________ _____________________________________ ___________________________________________ _____________________________________ ___________________________________________ _____________________________________ ___________________________________________ _____________________________________ ___________________________________________ _____________________________________ ___________________________________________ _____________________________________ ___________________________________________ _____________________________________ ___________________________________________ _____________________________________ ___________________________________________ _____________________________________ ___________________________________________ _____________________________________ ___________________________________________ _____________________________________ [F] FIRE __________________________________________ [A] AUXILIARY ____________________________________ [P] PANIC ________________________________________ The Exit Delay Time is ________ seconds.
  • Page 6: Access Codes

    Access Codes Access codes are used to arm and disarm the system. There are 37 access codes available: 1 master code, 32 regular access codes, 2 duress codes and 2 supervision codes. Ask your installer for more information on using the duress and supervision codes. Only the Master Code can be used to program additional security codes and to change other system features as well as to arm and disarm the security system.
  • Page 7: Alternate Arming Methods

    Alternate Arming Methods Away Arming Arming the system in the Away mode will have all interior zones and perimeter zones active. If motion is detected in the interior zones, or if one of the perimeter zones is violated, the alarm sequence will begin.
  • Page 8: Disarming The System

    Quick Exit When the Quick Exit feature is enabled, pressing [ ][0] while the system is armed will provide a two minute window for you to exit the premises. During this time, you may only open and close the designated Entry/Exit door once. Once the door is closed, the panel will end the two minute quick exit delay.
  • Page 9: Programming Security Codes

    NOTE: If you return and find that an alarm has occurred while you were away, it is possible that an intruder may still be on the premises. Go to a neighbour's house, and call the local police to investigate. The alarm memory is cleared each time the panel is armed so that any alarms showing are alarms that occurred only during the last armed period.
  • Page 10 PC1555RKZ LED Keypad Emergency Keys (All Keypads) PC5508Z, PC5516Z, PC5532Z, LCD5500Z: Press both * Keys for two seconds to send a FIRE transmission. Press both * Keys for two seconds to send an AUXILIARY transmission. Press both * Keys for two seconds to send a PANIC transmission.
  • Page 11 PC5508Z LED Keypad LCD5500Z Keypad The Liquid Crystal Display (LCD) displays prompts PC5516(Z) LED Keypad and system information on two 16 character lines. If “< >” appears, more information can be accessed by using the arrow (< >) keys. Press [<] to see the previous function or item of information.
  • Page 12 To erase a code: Enter [ ][5][Master Code][code number 01 to 32][ ]. Press [#] to return to the Ready state. The Master code cannot be erased. Programming codes from an LCD Keypad: Master Code Press the [ ] key to enter the function list. Scroll (< >) to... Press [5] or [ ].
  • Page 13: Viewing Trouble Conditions

    Zone Bypassing The zone bypassing function is used when access is needed to part of the protected area while the system is armed. Zones which are temporarily out of service due to damaged wiring or contacts may be bypassed to allow system arming until repairs can be made. Bypassed zones will not cause an alarm.
  • Page 14: Setting The System Date And Time

    To view troubles from an LED Keypad: A trouble will be indicated by the Trouble light (or System light on a PC1555RKZ keypad) which will remain ON until the trouble condition is cleared. If you cannot determine the cause of the trouble condition, contact your installer for assistance.
  • Page 15: Testing Your System

    Testing Your System Alarm Test The Alarm Test provides two second test of the keypad sounder and bell or siren. Begin with the panel in the Ready state. From an LED keypad, Enter [ ][6][Master Code][4] then press [#] to return to the Ready state. From an LCD keypad, press [ ] to enter the functions list.
  • Page 16: Keypad Options

    To activate the door chime from an LCD Keypad: Press [ ] to enter the function list, then scroll to find... Press [ ] or [4] to enable or disable the Door Chime feature. Press [#] to return to Press (*) For<> the Ready state.
  • Page 17: Household Fire Safety Audit

    To reset smoke detectors from an LCD Keypad: Press [ ] to enter the function list. Scroll to find: Press [ ] to select the output control. The display will read... Press (*) For <> Output Control Use the arrow (< >) keys to find the following message and press the [ ] key to Select Output <>...
  • Page 18: Fire Escape Planning

    Fire Escape Planning There is often very little time between the detection of a fire and the time it becomes deadly. It is thus very important that a family escape plan be developed and rehearsed. 1. Every family member should participate in developing the escape plan. 2.
  • Page 19: Limited Warranty

    LIMITED WARRANTY Digital Security Controls Ltd.’s liability for failure to repair the prod- uct under this warranty after a reasonable number of attempts will be Digital Security Controls Ltd. warrants the original purchaser that limited to a replacement of the product, as the exclusive remedy for for a period of twelve months from the date of purchase, the prod- breach of warranty.
  • Page 20 equivalent, in such a manner as to allow for easy, immediate disconnection FCC COMPLIANCE STATEMENT of the terminal equipment. Standard jacks shall be so arranged that, if the CAUTION: Changes or modifications not expressly approved by Digital plug connected thereto is withdrawn, no interference to the operation of the Security Controls Ltd.

This manual is also suitable for:

Classic pc1565

Table of Contents