14-2. Outdoor Unit

RAV-SM563AT-E, RAV-SM803AT-E
No.
Part name

Common
procedure
Never forget to put on the gloves at
working time, otherwise an injury will be
caused by the parts, etc.
1. Detachment
1) Stop operation of the air conditioner, and
turn off the main switch of the breaker for
air conditioner.
2) Remove the valve cover.
(ST1T Ø4 × 10L, 1 pc.)
• After removing screw, remove the valve
3) Remove wiring cover (ST1T Ø4 × 10L, 2
pcs.), and then remove connecting cable.
4) Remove the upper cabinet.
(ST1T Ø4 × 10L, 2 pcs.)
• After taking off screws, remove the
2. Attachment
1) Attach the waterproof cover.
Be sure to attach a waterproof cover.
If it is not attached, there is a possibility
that water enters inside of the outdoor
unit.
2) Attach the upper cabinet.
(ST1T Ø4 × 10L, 2 pcs.)
• Hook the rear side of the upper cabinet
3) Perform cabling of connecting cables,
and fix with cord clamp.
(ST1T Ø4 × 10L 3 pcs.)
4) Attach the wiring cover.
(ST1T Ø4 × 10L, 2 pcs.)
5) Attach the valve cover.
(ST1T Ø4 × 10L, 1 pc.)
• Insert the upper part of the upper
Tel: 01823 665660
Heronhill - for all your Toshiba requirements
Procedure
CAUTION
cover pulling it downward.
upper cabinet pulling it upward.
CAUTION
to claw of the rear cabinet, and then put
it on the front cabinet.
cabinet, set hooking claw of the valve
cover to the slit (at three positions) of
the main body, and then attach it
pushing upward.
– 134 –
www.heronhill.co.uk
Revised : Mar. 2007
Remarks
Valve
cover
Wiring
cover
Upper cabinet
Water-proof
cover
Cord clamp
Rear cabinet
Claw
Fax: 01823 665807