IMPINGER
Model
Energy
***1021-xxx-E
Electric
1022
Electric
1023
Electric
1028
Electric
1029
Electric
1032
Electric
1202
Electric
1203
Electric
1228
Electric
1229
Electric
Model
Energy
1030
Nat. Gas
1031
L.P. Gas
***1033-xxx-E
Nat. Gas
***1034-xxx-E
L.P. Gas
1040
Nat. Gas
1041
L.P. Gas
1042
Nat. Gas
1043
L.P. Gas
1046
Nat. Gas
1047
L.P. Gas
1240
Nat. Gas
1241
L.P. Gas
1242
Nat. Gas
1243
L.P. Gas
NOTE: All ovens require separate service and dedicated neutral.
4
I AND III CONVEYOR OVENS – MODEL SERIES 1000 AND 1200
UTILITY SPECIFICATIONS REQUIRED – ELECTRIC
Power
Voltage
27 kW
400/230 VAC
27 kW
120/208 VAC
27 kW
120/240 VAC
380Y/220
27 kW
VAC
27 kW
415/240 VAC
380Y/220
27 kW
VAC
27 kW
120/208 VAC
27 kW
120/240 VAC
380Y/220
27 kW
VAC
27 kW
415/240 VAC
UTILITY SPECIFICATIONS REQUIRED – GAS
Power
Voltage
Current
220
35 kW
1.6 Amps
VAC
220
35 kW
1.6 Amps
VAC
230
35 kW
3 Amps
VAC
230
35 kW
3 Amps
VAC
120,000
120/230
5 Amps
BTU
VAC
120,000
120/230
5 Amps
BTU
VAC
120,000
230
5 Amps
BTU
VAC
120,000
230
5 Amps
BTU
VAC
240
126 MJ
5 Amps
VAC
240
126 MJ
5 Amps
VAC
120,000
120/230
5 Amps
BTU
VAC
120,000
120/230
5 Amps
BTU
VAC
120,000
230
5 Amps
BTU
VAC
120,000
230
5 Amps
BTU
VAC
Current
Phase
Hz
40 Amps
3
50 Hz
80 Amps
3
60 Hz
70 Amps
3
60 Hz
41 Amps
3
50 Hz
38 Amps
3
50 Hz
41 Amps
3
50 Hz
80 Amps
3
60 Hz
70 Amps
3
60 Hz
41 Amps
3
50 Hz
38 Amps
3
50 Hz
Phase
Frequency
1
50 Hz
1
50 Hz
1
50 Hz
1
50 Hz
1
60 Hz
1
60 Hz
1
50 Hz
1
50 Hz
1
50 Hz
1
50 Hz
1
60 Hz
1
60 Hz
1
50 Hz
1
50 Hz
Recommended Electrical
Specifications
5 Wires, 3 Poles
1N-1G
5 Wires, 3 Poles
1N-1G
5 Wires, 3 Poles
1N-1G
5 Wires, 3 Poles
1N-1G
5 Wires, 3 Poles
1N-1G
5 Wires, 3 Poles
1N-1G
5 Wires, 3 Poles
1N-1G
5 Wires, 3 Poles
1N-1G
5 Wires, 3 Poles
1N-1G
5 Wires, 3 Poles
1N-1G
Recommended
Electrical
Gas
Specification
35 kW/hr at 17.5
3 Wires, 1 Pole
mB H
O column
1N-1G
2
3 Wires, 1 Pole
35 kW/hr at 27.5
1N–1G
mB H
O column
2
3 Wires, 1 Pole
35 kW/hr at 17.5
1N-1G
mB H
O column
2
3 Wires, 1 Pole
35 kW/hr at 27.5
1N-1G
mB H
O column
2
4 Wires, 1 Pole
120,000 BTU at 7
1N-1G
inches H
O column
2
120,000 BTU at 11
4 Wires, 1 Pole
inches H
O column
1N-1G
2
3 Wires, 1 Pole
120,000 BTU at 7
1N-1G
inches H
O column
2
120,000 BTU at 11
3 Wires, 1 Pole
1N-1G
inches H
O column
2
126 MJ/hr at 1.75
3 Wires, 1 Pole
1N-1G
kPa H
O column
2
3 Wires, 1 Pole
126 MJ/hr at 1.75
1N-1G
kPa H
O column
2
120,000 BTU at 7
4 Wires, 1 Pole
inches H
O column
1N-1G
2
4 Wires, 1 Pole
120,000 BTU at 11
1N-1G
inches H
O column
2
120,000 BTU at 7
3 Wires, 1 Pole
1N-1G
inches H
O column
2
3 Wires, 1 Pole
120,000 BTU at 11
1N-1G
inches H
O column
2
Impinger I – 1000 Series Ops Manual
Agency
Listing
F-G
A-B-F
A-B-F
F
F
F
A-B-F
A-B-F
F
F
Agency
Listing
F
F
F-G
F-G
A-F
A-F
F
F
E-F
E-F
A-F
A-F
F
F