Cleaning And Maintenance - Legend DV36NG Owner's Manual

Direct-vent gas fireplace
Table of Contents

Advertisement

CLEANING AND MAINTENANCE

Make sure the gas valve knob is in the "OFF" position. Wait at least five (5) minutes before starting
maintenance. Fireplace must be cold before starting maintenance.
VENTING SYSTEM
A qualified agency should examine the venting system annually.
CLEANING GLASS
CAUTION
Let glass cool before cleaning. Do not clean glass when it is hot. Damage could occur.
Clean the tempered glass periodically. Condensation will sometimes form on the glass during a cold
startup. This is normal for all gas fireplaces. This condensation often attracts dust and lint to the surface
of the glass. The initial paint curing of the appliance can also leave a slight film on the glass. You should
clean the glass after the first two weeks of use. After that, you should clean the glass no more than two
or three times a season. Use a mild glass cleaner to clean the door. Do not use abrasive cleaners. They
will damage the glass surface.
PILOT AND BURNER FLAMES
Visually check pilot and burner flames periodically.
Firebox cleaning:
1. Carefully remove ceramic fibre logs from burner pan.
2. Vacuum burner compartment thoroughly.
3. Vacuum or brush with soft brush any dust burner pan
4. Remove any lint from main burner and pilot.
5. Carefully replace ceramic fibre logs.
6. Replace door (if it has been removed).
7. Relight pilot.
8. Turn on main burner.
WARNING
Make sure clearances to combustibles leave room for maintenance and service. Carefully
reassemble and reseal fireplace properly after any cleaning or servicing.