Scantech V-1010BT User Manual

Wireless handheld linear imager bar code scanner
Hide thumbs Also See for V-1010BT:
Table of Contents

Advertisement

Quick Links

U s e r ' s
M a n u a l
V-1010BT Wireless Handheld Linear
Imager Bar code Scanner

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the V-1010BT and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Scantech V-1010BT

  • Page 1 U s e r ’ s M a n u a l V-1010BT Wireless Handheld Linear Imager Bar code Scanner...
  • Page 2 In particular, Scantech-ID BV shall not be liable for any hardware, software, or data that is stored or used with the product, including the cost of repairing, replacing or recovering the above.
  • Page 3: Table Of Contents

    PRODUCT SAFETY ......2 Safety & Caution ......2 FCC Warning ......3 CHAPTER 2 GENERAL DESCRIPTION ......4 Use of the V-1010BT ...... 4 CHAPTER 3 INSTALLATION OF THE V-1010BT ....5 V-1010BT Unpacking ....... 5 V-1010BT Cradle Installation ..... 6 V-1010BT Setup Bluetooth Communication ...
  • Page 4 4.3.1 Abort Configuration ...... 14 4.3.2 Recall ........14 4.3.3 Version Information ...... 14 Cradle Interface Selection ....14 4.4.1 Interface ........ 14 Bluetooth Scanner Setup ....15 4.5.1 Preface ........15 4.5.2 Scanner Mode ......15 4.5.3 *** Batch Mode (“***” means “Quick Setting Label”, The function can be executed directly by scanning barcode instead of doing the general programming process.) ......
  • Page 5 4.8.3 Parity ........22 4.8.4 Handshaking ....... 23 Keyboard Wedge Mode Parameters ..24 4.9.1 Terminal Type ......24 4.9.2 Country/Language ......25 4.9.3 Upper/Lower Case ......26 4.9.4 Capslock Detection ......26 4.9.5 Character by ALT Method ....27 4.9.6 Select Numerical Pad ......
  • Page 6 4.14.4 Setup Code Length ......39 4.15 Interleave 2 of 5 Parameters ..... 40 4.15.1 Check Digit Transmission ....40 4.15.2 Setup Number of Character ....40 4.15.3 Brazilian Banking Code ....41 4.15.4 Setup Code Length ......41 4.16 Industrial 2 of 5 Parameters ..... 43 4.16.1 Reading Type ......
  • Page 7 4.22.2 Check Digit Transmission ....56 4.22.3 Setup Code Length ......56 4.23 GS1 Databar Omnidirectional Parameters .. 58 4.23.1 Check Digit Transmission ....58 4.23.2 Application ID ......58 4.23.3 Symbology ID ......58 4.24 GS1 Databar Limited Parameters ..59 4.24.1 Check Digit Transmission ....
  • Page 8 APPENDIXES ..........73 Decimal Value Table ...... 73 ASCII Value Table ......74 ASCII Table ......75 Function Key Table ....... 81 Technical Specifications ....82 Scan Map ......... 84 LED Indicator Status ..... 85 Test Symbologies ......86 Quick Configuration ...... 88...
  • Page 9: Introduction

    To the brand new series of V-1010BT, we add on more user- friendly functions with detachable interface cable that makes it easier to be operated by the customers.
  • Page 10: Product Safety

    Please read the following safety statement carefully. Please preserve this user’s manual for reference sometime. Before cleaning the V-1010BT, the users must cut off all AC power. Do not use liquid or spray type of detersive to clean the V-1010BT. Please use dampish cotton cloth to clean the V-1010BT.
  • Page 11: Table Of Contents

    1.2 FCC Warning This equipment complies with the requirements in Part 15 of FCC. Any operation must comply with the conditions below: (a) The equipment will not cause any severe interference. (b) The equipment can avoid any interference from environment. Statement: This product is classified as B class product.
  • Page 12: General Description

    LED indicator will light on after scan successfully. The programming of the V-1010BT is very easy. You can setup the V-1010BT by scan all necessary programming codes that meet applications. Thanks to the powerful decoding software, the V-1010BT can decode all major 1D codes.
  • Page 13: Installation Of The V-1010Bt

    1010BT 3.1 V-1010BT Unpacking Unpack the V-1010BT as follows: 1. Take the V-1010BT and its accessories out of the box. 2. Remove the packing material. 3. Check the packing list to make sure you have received all of the items ordered.
  • Page 14: V-1010Bt Cradle Installation

    3.2 V-1010BT Cradle Installation To setup your V-1010BT scanner with Bluetooth technology, please follow the steps. 1. Connect the supplied communication cable at the bottom side of the cradle. 2. Connect the other side of the communication cable to the right connector of your POS or HOST system.
  • Page 15: V-1010Bt Setup Bluetooth Communication

    This address code is located on the bottom side of the cradle. The pairing of a V-1010BT scanner to a cradle is one to one. Only one V- 1010BT scanner can be paired to a cradle at any point in time.
  • Page 16 V-1010BT scanner can’t be paired with that cradle until the original connection is interrupted. If you pair a second V-1010BT scanner to an in-use cradle, the cradle’s connection to the first V-1010BT scanner will be interrupted and the connection will be re-...
  • Page 17: Setup Spp Slave Mode Communication

    3.3.5 The V-1010BT scanner enters sleep mode to save battery energy, when the V-1010BT scanner is used for 1 minute or 10 minute time. During sleep mode all the functions and connection will be halted. After press the red trigger button the scanner will wake up and reconnect the communication with the cradle or Bluetooth device.
  • Page 18: Batch Mode

    Batch Mode 3.3.6 This batch mode is enabled when you have scanned “Batch Mode on”. The scanned data is stored in the memory of the SG700BT scanner instead of being transmitted. You can delete the last scanned bar code data by scanning “Delete Last Data”...
  • Page 19: Configuring The V-1010Bt

    V-1010BT scanner settings with programming labels. Changing Scanner Settings with 4.1.1 Programming Codes You can setup your V-1010BT by scan all necessary programming codes that meet applications. In order to change the scanner settings please follow the sequence below: 1. Power up the scanner.
  • Page 20: Programming Flow Chart

    By scanning “Set All Default” label, the settings will go back to the factory default settings. Programming Flow Chart 4.1.2 Start Recall Set all Default Configuration Parameters Interface Selection Communication Parameters Bar codes Parameters Misc. Parameters etc. Abort Configuration Configuration Save Parameters...
  • Page 21: Set All Default Parameter

    4.2 Set All Default Parameter By scanning “Set All Default” label, the all parameters will go back to the factory default settings for scanner and cradle. After reading a valid programming code the scanner will give three high beep and the Green LED indicator will light on.
  • Page 22: Abort Configuration

    Abort Configuration 4.3.1 Terminate current programming status. Recall 4.3.2 Replace the current parameters by the parameters saved last time Version Information 4.3.3 Display the Scanner version information and date code Display the Cradle version information and date code Display the Scanner Bluetooth MAC Address Display the Cradle Bluetooth MAC Address...
  • Page 23: Bluetooth Scanner Setup

    USB Virtual Comport Mode Bluetooth Scanner Setup Preface 4.5.1 How to configure the Bluetooth function: The barcode programming feature gives the possibility to change the V-1010BT scanner settings with programming labels. Scanner Mode 4.5.2 BT Parameter set default SPP Master Mode...
  • Page 24: Batch Mode

    *** Batch Mode 4.5.3 (“***” means “Quick Setting Label”, The function can be executed directly by scanning barcode instead of doing the general programming process.) ***Batch Mode ON ***<Batch Mode OFF> ***Batch Data Output ***Batch Data Clear ***Delete Last Data Out of Range 4.5.4 <Out of Range Enable>...
  • Page 25: Scanner Pincode Mode

    Sleep Mode On 10 minute <Sleep Mode OFF> Scanner Pincode Mode 4.5.6 Default Security code (PINCODE=000000) Security Code ON <Security Code OFF> Scanner Pincode Setup 4.5.7 Set PINCODE Max 6 Digits, 0-9 and A-Z ASCII Code Go to ASCII table in Appendix B, scan 6 labels that represent the PINCODE Complete to Set PINCODE...
  • Page 26: Bluetooth Cradle Setup

    4.6 Bluetooth Cradle Setup Cradle Pincode Mode 4.6.1 Default Security code (PINCODE=000000) Security Code ON <Security Code OFF> Cradle Pincode Setup 4.6.2 Set PINCODE Max 6 Digits, 0-9 and A-Z ASCII Code Go to ASCII table in Appendix B, scan 6 labels that represent the PINCODE Complete to Set PINCODE...
  • Page 27: Beeper Option

    Trigger ON/OFF Continuous/Trigger OFF Continuous/Auto Power ON Flash Flash/Auto Power ON Auto Sence Beeper Option 4.7.2 <High> Medium...
  • Page 28: Reading Level

    Reading Level 4.7.3 Bar Equals High <Bar Equals Low> Accuracy Scan 4.7.4 < Require 1 good decoding for a good scan> Require 2 consecutive decoding of the same bar code data for a good scan Require 3 consecutive decoding of the same bar code data for a good scan Require 4 consecutive decoding of...
  • Page 29: Reverse Output Characters

    Reverse Output Characters 4.7.6 Example: 012345  543210 Enable <Disable> 4.8 RS232 Mode Parameters Baud Rate 4.8.1 1200 2400 4800 <9600> 19200 38400 57600...
  • Page 30: Data/Stop Bits

    Data/Stop Bits 4.8.2 The number of data/stop bits transmitted for each character 7 Data Bits < 8 Data Bits > < 1 Stop Bits > 2 Stop Bits Parity 4.8.3 A Parity bit is an extra data bit used to check data transmission errors.
  • Page 31: Handshaking

    Handshaking 4.8.4 RTS/CTS ON – Output a Request to Send (RTS) signal and wait for a Clear to Send (CTS) signal before transmitting data <RTS/CTS OFF> ACK/NAK ON – After transmitting data, wait for host to send an ACK or a NAK response. If ACK is received, then complete the data transmission.
  • Page 32: Keyboard Wedge Mode Parameters

    4.9 Keyboard Wedge Mode Parameters Terminal Type 4.9.1 <IBM PC/AT,PS/2> - Includes IBM PS/2 and compatible models 50, 55, 60, 80 IBM PC/XT IBM PS/2 25, 30 IBM 5550 IBM 102 Key IBM 122 Key (1) IBM 122 Key (2) NEC 9800 Apple Desktop Bus(ADB)
  • Page 33: Country/Language

    Country/Language 4.9.2 <US English> UK English Italian Spanish French German Swedish Switzerland Hungarian Japanese Belgium...
  • Page 34: Upper/Lower Case

    Portuguese Denmark Netherlands Turkey Upper/Lower Case 4.9.3 <No Change> Enable Lower Case – Transmit all data as lower case Enable Upper Case – Transmit all data as upper case Capslock Detection 4.9.4 Enable <Disable>...
  • Page 35: Character By Alt Method

    Character by ALT Method 4.9.5 ALT Method Enable <ALT Method Disable> Select Numerical Pad 4.9.6 Numerical Pad ON <Numerical Pad OFF> Interscan Code Delay 4.9.7 <No Delay> 5 ms 10 ms 25 ms 50 ms...
  • Page 36: Output Characters

    100 ms 200 ms 300 ms 4.10 Output Characters Select Terminator 4.10.1 <CR+LF>– The scanner transmits a carriage return and a line feed after each scan CR Suffix – The scanner transmits a carriage return after each scan LF Suffix – The scanner transmits a line feed after each scan Space STX-ETX –...
  • Page 37: Code Type

    4.11 Code Type Barcode Selection 4.11.1 If “All Bar Code ON” is selected, the scanner could read all types of bar code. If “Disable” is selected for a certain bar code type, the scanner could not read the particular bar code. The symbol of “<>” means default setting.
  • Page 38 <CODE 39 ON> CODE 39 OFF Code32 / Italian Pharmacy ON <Code32 / Italian Pharmacy OFF> <Code 128 ON> Code 128 OFF <Interleave 2 of 5 ON> Interleave 2 of 5 OFF <Codabar/NW7 ON> Codabar/NW7 OFF Industrial 2 of 5 ON <Industrial 2 of 5 OFF>...
  • Page 39 Matrix 2 of 5 ON <Matrix 2 of 5 OFF> CODE 93 ON <CODE 93 OFF> CODE 11 ON <CODE 11 OFF> MSI/PLESSEY ON <MSI/PLESSEY OFF> Telepen ON <Telepen OFF> China Postage ON <China Postage OFF>...
  • Page 40: Upc/Ean/Jan Parameters

    GS1 DataBar Omnidirectional ON <GS1 DataBar Omnidirectional OFF> GS1 DataBar Expanded ON <GS1 DataBar Expanded OFF> GS1 DataBar Limited ON <GS1 DataBar Limited OFF> 4.12 UPC/EAN/JAN Parameters Reading Type 4.12.1 UPC-A=EAN-13 ON Add 0 before UPC-A to make it 13 digits.
  • Page 41 ISSN Enable <ISSN Disable> Decode with Supplement <Auto Discriminate Supplement> Expand UPC-E Enable <Expand UPC-E Disable> EAN8=EAN13 Enable <EAN8=EAN13 Disable> GTIN Format Enable <GTIN Format Disable>...
  • Page 42: Supplemental Setup

    Supplemental Setup 4.12.2 <Not Transmit> 2 Digit Supplemental 5 Digit Supplemental 2 & 5 Digit Supplemental Check Digit Transmission 4.12.3 <UPC-A Check Digit Transmission ON> UPC-A Check Digit Transmission OFF <UPC-E Check Digit Transmission ON> UPC-E Check Digit Transmission OFF <EAN-8 Check Digit Transmission ON>...
  • Page 43: Code 39 Parameters

    <EAN-13 Check Digit Transmission ON> EAN-13 Check Digit Transmission OFF <ISSN Check Digit Transmission ON> ISSN Check Digit Transmission OFF 4.13 Code 39 Parameters Type of Code 4.13.1 <Standard Code 39> Full ASCII Code 39 Check Digit Transmission 4.13.2 <Do Not Calculate Check Digit> Calculate Check Digit and Transmit Calculate Check Digit and Not Transmit...
  • Page 44: Output Start/Stop Character

    Output Start/Stop Character 4.13.3 Enable <Disable> Decode Asterisk 4.13.4 Enable <Disable> Setup Code Length 4.13.5 To set the fixed length: (2 sets available) 1. Scan the “Begin” programming code of the desired set. 2. Go to the Decimal Value Table in Appendix A. Scan programming codes that represent the length to be read.
  • Page 45 Set Begin Decimal Value See Appendix A Set Complete Fixed Length 2 Set Begin Decimal Value See Appendix A Set Complete Minimum Length Minimum Length Begin Decimal Value See Appendix A Minimum Length Complete...
  • Page 46: Code 128 Parameters

    4.14 Code 128 Parameters Reading Type 4.14.1 UCC/EAN-128 Enable <UCC/EAN-128 Disable> Check Digit Transmission 4.14.2 Do Not Calculate Check Digit Calculate Check Digit and Transmit <Calculate Check Digit and Not Transmit> Append FNC2 4.14.3 <OFF>...
  • Page 47: Setup Code Length

    Setup Code Length 4.14.4 To set the fixed length: (2 sets available) 1. Scan the “Begin” programming code of the desired 2. Go to the Decimal Value Table in Appendix A. Scan programming codes that represent the length to be read.
  • Page 48: Interleave 2 Of 5 Parameters

    Set Complete Minimum Length Minimum Length Begin Decimal Value See Appendix A Minimum Length Complete 4.15 Interleave 2 of 5 Parameters Check Digit Transmission 4.15.1 <Do Not Calculate Check Digit> Calculate Check Digit and Transmit Calculate Check Digit and Not Transmit Setup Number of Character 4.15.2...
  • Page 49: Brazilian Banking Code

    Brazilian Banking Code 4.15.3 Enable <Disable> Setup Code Length 4.15.4 To set the fixed length: (2 sets available) 1. Scan the “Begin” programming code of the desired 2. Go to the Decimal Value Table in Appendix A. Scan programming codes that represent the length to be read.
  • Page 50 Set Complete Fixed Length 2 Set Begin Decimal Value See Appendix A Set Complete Minimum Length Minimum Length Begin Decimal Value See Appendix A Minimum Length Complete...
  • Page 51: Industrial 2 Of 5 Parameters

    4.16 Industrial 2 of 5 Parameters Reading Type 4.16.1 IATA25 Enable <IATA25 Disable> Check Digit Transmission 4.16.2 <Do Not Calculate Check Digit> Calculate Check Digit and Transmit Calculate Check Digit and Not Transmit Setup Code Length 4.16.3 To set the fixed length: (2 sets available) 1.
  • Page 52 <Variable> Fixed Length 1st Set Set Begin Decimal Value See Appendix A Set Complete Fixed Length 2 Set Begin Decimal Value See Appendix A Set Complete Minimum Length Minimum Length Begin...
  • Page 53: Matrix 2 Of 5 Parameters

    Decimal Value See Appendix A Minimum Length Complete 4.17 Matrix 2 of 5 Parameters Check Digit Transmission 4.17.1 <Do Not Calculate Check Digit> Calculate Check Digit and Transmit Calculate Check Digit and Not Transmit Setup Code Length 4.17.2 To set the fixed length: (2 sets available) 1.
  • Page 54 <Variable> Fixed Length 1 Set Begin Decimal Value See Appendix A Set Complete Fixed Length 2 Set Begin Decimal Value See Appendix A Set Complete Minimum Length Minimum Length Begin Decimal Value See Appendix A...
  • Page 55: Codabar/Nw7 Parameters

    Minimum Length Complete 4.18 CODABAR/NW7 Parameters Setup Start/Stop Characters upon 4.18.1 Transmission <OFF> Transmission Type of Start/Stop 4.18.2 A/B/C/D <Start> A/B/C/D <Stop> A Start A Stop B Start...
  • Page 56: Setup Code Length

    B Stop C Start C Stop D Start D Stop Setup Code Length 4.18.3 To set the fixed length: (2 sets available) 1. Scan the “Begin” programming code of the desired 2. Go to the Decimal Value Table in Appendix A. Scan programming codes that represent the length to be read.
  • Page 57 Decimal Value See Appendix A Set Complete Fixed Length 2 Set Begin Decimal Value See Appendix A Set Complete Minimum Length Minimum Length Begin Decimal Value See Appendix A Minimum Length Complete...
  • Page 58: Code 93 Parameters

    4.19 Code 93 Parameters Check Digit Transmission 4.19.1 Do Not Calculate Check Digit <Calculate Check 2 Digit and Not Transmit> Setup Code Length 4.19.2 To set the fixed length: (2 sets available) 1. Scan the “Begin” programming code of the desired 2.
  • Page 59: Code 11 Parameters

    Set Complete Fixed Length 2 Set Begin Decimal Value See Appendix A Set Complete Minimum Length Minimum Length Begin Decimal Value See Appendix A Minimum Length Complete 4.20 Code 11 Parameters Check Digit Transmission 4.20.1 <Do Not Calculate Check Digit>...
  • Page 60: Setup Code Length

    Calculate Check 1 Digit and Transmit Calculate Check 1 Digit and Not Transmit Calculate Check 2 Digit and Transmit Calculate Check 2 Digit and Not Transmit Setup Code Length 4.20.2 To set the fixed length: (2 sets available) 1. Scan the “Begin” programming code of the desired 2.
  • Page 61 Decimal Value See Appendix A Set Complete Fixed Length 2 Set Begin Decimal Value See Appendix A Set Complete Minimum Length Minimum Length Begin Decimal Value See Appendix A Minimum Length Complete...
  • Page 62: Msi/Plessey Code Parameters

    4.21 MSI/Plessey Code Parameters Check Digit Transmission 4.21.1 <Do Not Calculate Check Digit> Calculate Check Digit and Transmit Calculate Check Digit and Not Transmit Setup Code Length 4.21.2 To set the fixed length: (2 sets available) 1. Scan the “Begin” programming code of the desired 2.
  • Page 63 Decimal Value See Appendix A Set Complete Fixed Length 2 Set Begin Decimal Value See Appendix A Set Complete Minimum Length Minimum Length Begin Decimal Value See Appendix A Minimum Length Complete...
  • Page 64: Telepen Parameters

    4.22 Telepen Parameters Type of Code 4.22.1 <Telepen ASCII ON> Telepen Numeric Check Digit Transmission 4.22.2 Do Not Calculate Check Digit Calculate Check Digit and Transmit <Calculate Check Digit and Not Transmit> Setup Code Length 4.22.3 To set the fixed length: (2 sets available) 1.
  • Page 65 <Variable> Fixed Length 1 Set Begin Decimal Value See Appendix A Set Complete Fixed Length 2 Set Begin Decimal Value See Appendix A Set Complete Minimum Length Minimum Length Begin Decimal Value See Appendix A Minimum Length Complete...
  • Page 66: Gs1 Databar Omnidirectional Parameters

    4.23 GS1 Databar Omnidirectional Parameters Check Digit Transmission 4.23.1 <Calculate Check Digit and Transmit> Calculate Check Digit and Not Transmit Application ID 4.23.2 <Transmit Application ID> Add 01 before GS1 Databar Omnidirectional Do Not Transmit Application ID Symbology ID 4.23.3 Transmit Symbology ID Add ]e0 before GS1 Databar Omnidirectional.
  • Page 67: Gs1 Databar Limited Parameters

    4.24 GS1 Databar Limited Parameters Check Digit Transmission 4.24.1 <Calculate Check Digit and Transmit> Calculate Check Digit and Not Transmit Application ID 4.24.2 <Transmit Application ID> Add 01 before GS1 Databar Limited. Don’t Transmit Application ID Symbology ID 4.24.3 Transmit Symbology ID Add ]e0 before GS1 Databar Limited.
  • Page 68: Gs1 Databar Expanded Parameters

    4.25 GS1 Databar Expanded Parameters Symbology ID 4.25.1 Transmit Symbology ID Add ]e0 before GS1 Databar Expanded. <Don’t Transmit Symbology ID>...
  • Page 69: Miscellaneous Parameters

    CHAPTER 5 MISCELLANEOUS PARAMETERS 5.1 Bar Code ID Default Barcode ID 5.1.1 With this function on, a leading character will be added to the output string while scanning code. User may refer to the following table to know what kind of barcode has being scanned.
  • Page 70: User Define Code Id

    Bar Code ID ON <Bar Code ID OFF> Default – Return from User Define to Default User Define Code ID 5.1.2 To set the code ID 1. Scan the symbologies programming code. 2. Go to the ASCII Table in Appendix B. Scan programming codes that represent the desired ID.
  • Page 71 CODE 128 Codabar/NW7 Interleave 2 of 5 Industrial 2 of 5 Matrix 2 of 5 CODE 93 CODE 11 China Postage MSI/PLESSEY Telepen GS1 DataBar Omnidirectional...
  • Page 72: Preamble And Postamble Insertion

    GS1 DataBar Expanded GS1 DataBar Limited 5.2 Preamble and Postamble Insertion Setup Insertion 5.2.1 To set the insertion of the output characters: 1. Scan the programming code of the desired set. 2. Scan the programming code of the desired symbology 3.
  • Page 73: Insertion Set Number

    Code UPC-A 1st Digit Complete Complete End Configuration Save Parameters Insertion Set Number 5.2.2...
  • Page 74: Code Type For Insertion

    Code Type for Insertion 5.2.3 UPC-A UPC-E EAN-13/JAN-13 EAN-8/JAN-8 CODE 39 CODE 128 Codabar/NW7 Interleave 2 of 5...
  • Page 75 Industrial 2 of 5 Matrix 2 of 5 CODE 93 CODE 11 China Postage MSI/PLESSEY Telepen GS1 DataBar Omnidirectional GS1 DataBar Expanded GS1 DataBar Limited All Codes...
  • Page 76: Position To Be Inserted

    None Position to Be Inserted 5.2.4 Decimal Value See Appendix A Complete Characters to Be Inserted 5.2.5 ASCII Table See Appendix B and C Complete 5.3 Character Deletion To setup the deletion of output characters: 1. Scan the programming code of the desired set. 2.
  • Page 77 Repeat the steps 1 – 6 to set additional deletion. Example: Delete first 3 digits Code EAN-13. Start Configuration Code EAN-13 1st Digit – Delete from the 1 digit Complete – Delete 3 digits Complete End Configuration Save Parameters...
  • Page 78: Deletion Set Number

    Deletion Set Number 5.3.1 Code Type for Deletion 5.3.2 UPC-A UPC-E EAN-13/JAN-13 EAN-8/JAN-8...
  • Page 79 CODE 39 CODE 128 Codabar/NW7 Interleave 2 of 5 Industrial 2 of 5 Matrix 2 of 5 CODE 93 CODE 11 China Postage MSI/PLESSEY Telepen...
  • Page 80: Position To Be Deleted

    GS1 DataBar Omnidirectional GS1 DataBar Expanded GS1 DataBar Limited All Codes None Position to Be Deleted 5.3.3 Decimal Value See Appendix A Complete Number of Characters to Be Deleted 5.3.4 Decimal Value See Appendix A Complete...
  • Page 81: Appendixes

    APPENDIXES Decimal Value Table...
  • Page 82: Ascii Value Table

    ASCII Value Table Enter...
  • Page 83: Ascii Table

    ASCII Table NULL...
  • Page 84 SPACE ″ &...
  • Page 85 Comma Minus Period Number Number One Zero < Less Than > Greater Than...
  • Page 86 Letter I Letter O...
  • Page 87 Underscore...
  • Page 88 Vertical Slash...
  • Page 89: Function Key Table

    Function Key Table Insert Delete Home Page Up Page Down Left Right...
  • Page 90: Technical Specifications

    Down Technical Specifications Physical Characteristics Scanner Scanner Weight Approx 197g (incl. batteries) Charger Weight Approx. 135g Material ABS Plastic Connector RJ 45C 10Pins Dimension 186.8 mm x 81.6 mm x 63.8 mm Physical Characteristics Bluetooth Cradle Weight Approx 132g Material ABS Plastic Connector RJ 45C 10Pins...
  • Page 91 Electrical Characteristics Scanner: Power Battery Li-ion 3.7V / 2600 mA. Charge Time 5.5 hours Reads per Charge 25,000 Times LED Indicator Good read: Green Error / Alarm: Red Bluetooth Communication: blue Power Consumption Power On 400mA Stand by 270mA Operation 290mA Sleep 36mA...
  • Page 92: Scan Map

    Environmental Operating Temp. 0°C to 50°C (32°F to 122°F) Storage Temp. -20°C to 70°C (-4°F to 158°F) Relative Humidity 20 to 95% non-condensing Ambient light 10,000 LUX max Immunity Ingress Protection Sealed with IP42 rating protection Scanner Drop Functions normally after repeated Specification 4ft./1.2m drops to concrete surface Regulatory of Compliance...
  • Page 93: Led Indicator Status

    E. LED Indicator Status Scanner Indicators Status Buzzer Green Light and Buzzer Power On Be-Be-Be* 2 loops Simultaneously Battery No Power Red Blink 3 times Bi-Bi-Bi Battery Low Power Alarm Red Blink 1 time Be per 20 seconds Battery Very Low Power Red Blink 4 times Bi-Bi-Bi-Bi per 10 seconds Alarm...
  • Page 94: Test Symbologies

    F. Test Symbologies Scan one or more of these bar codes to test symbologies you enabled. 1D Symbology Codabar/NW7 CODE 11 CODE 39 CODE 93 CODE 128 EAN 8 1234 5670 EAN 13 Interleave 2 of 5 1 234567 890128 ISBN ISSN GS1 DataBar Omnidirectional...
  • Page 95 GS1 Databar Limited MSI / Plessey Matrix 2 of 5 Industrial 2 of 5 UPC A UPC E 12345 67890 123456 Telepen China Postage...
  • Page 96: Quick Configuration

    Quick Configuration Start Configuration (Select your Settings) End Configuration Save Parameters Set All Defaults Recall Stored Parameters Abort Configuration Version Information...
  • Page 97 Scantech-ID BV Vanadiumweg 22 , 3812PZ Amersfoort The Netherlands. Tel:+31(0)-33-4698400 Fax:+31(0)-33-4650615 E-mail: info@scantech-id.com Internet: www.scantech-id.com...

Table of Contents