Table of Contents

Advertisement

Quick Links

GeneralProgrammingCodes ......................................... 1
How to use programming codes .............................. 1
Default Setting ................................................. 2
Serial Mode .............................................................. 2
Decode Normal and Inverse Data ............................ 3
Reading Mode .......................................................... 3
Manual Mode ................................................... 3
Auto Reading Mode ......................................... 3
Auto-Sensor Mode ........................................... 5
Command Trigger Reading Mode ................... 6
Decoding Status Prompt .......................................... 6
Other Settings .......................................................... 7
Temporary Mute Setting .................................. 7
Temporary LED Setting ................................... 7
Communications ............................................................ 8
Brief ......................................................................... 8
Communications Settings ........................................ 8
Serial Parameters Settings ....................................... 8
Baud Rate Setting ............................................ 8
Check ............................................................... 9
Stop Bit .......................................................... 10
Fluid Control .................................................. 10
Data Bit .......................................................... 10
KBW Settings ........................................................ 11
Keyboard Wedge ............................................ 11
Keyboard Layout ........................................... 15
Content
- I -

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DC-100 and is the answer not in the manual?

Questions and answers

Summary of Contents for Scantech DC-100

  • Page 1: Table Of Contents

    Content GeneralProgrammingCodes ......... 1 How to use programming codes ......1 Default Setting ..........2 Serial Mode .............. 2 Decode Normal and Inverse Data ......3 Reading Mode ............3 Manual Mode ........... 3 Auto Reading Mode ......... 3 Auto-Sensor Mode ........... 5 Command Trigger Reading Mode ....
  • Page 2 Time-delay Between Characters ....16 Letters Conversion ......... 16 F1~F12 ............17 Data Format ..............18 Brief ............... 18 Prefix In Order ............18 User-Defined Prefix ..........19 Enable or Disable User-Defined Prefix ..19 Define the User-Defined Prefix ..... 19 AIM ID Prefix............
  • Page 3 Return to Default ........... 25 Enable / Disable UCC/EAN-128 ....25 Code ID ............26 Code Length Limit ......... 26 AIM 128 ..............27 Return to Default ........... 27 Enable/Disable AIM 128 ....... 27 Code ID ............27 Code Length Limit ......... 27 EAN-8 ..............
  • Page 4 Enable/Disable ISSN ........32 Code ID ............33 ISBN ..............33 Return to Default ........... 33 Enable/DisableISBN ........33 ISBN Data Bit ..........34 Code ID 设置 ..........34 UPC-E ..............34 Return to Default ........... 34 Enable/Disable UPC-E ........34 Code ID ............
  • Page 5 Code ID ............39 Check ............. 40 Code Length Limit ......... 40 ITF-6 ..............41 Return to Default ........... 41 Enable/Disable ITF-6 ........41 Code ID ............41 ITF-14 ..............42 Return to Default ........... 42 Enable/Disable ITF-14 ........42 Code ID ............
  • Page 6 Code ID ............47 Check ............. 47 Code Length Limit ......... 48 Standard 25 ............49 Return to Default ........... 49 Enable/Disable Standard 25 ......49 Code ID ............49 Check ............. 49 Code Length Limit ......... 50 Code 39 ..............51 Return to Default ...........
  • Page 7 Check ............. 56 Code Length Limit ......... 57 Code 11 ..............58 Return to Default ........... 58 Enable/Disable Code 11 ......... 58 Code ID ............58 Check ............. 58 Code Length Limit ......... 59 Plessey ..............60 Return to Default ........... 60 Enable/Disable Plessey ........
  • Page 8 Enable/Disable AI of RSS_Limited ....65 Code ID ............65 RSS-Expand ............65 Return to Default ........... 65 Enable/Disable RSS-Expand ......66 Code ID ............66 Appendix ..............66 Default Setting Table ..........66 Data Code .............. 73 Save and Cancel Setting ........74 AIMID Table............
  • Page 9: Generalprogrammingcodes

    GeneralProgrammingCodes How to use programming codes Read the “Open Programming Mode” to activate the settings. It could read not only one programming mode to finish the setting. Programming data can be sent to the host. Factory default is no sending programming info to the host, sending programming expanded info or sending programming all info these two settings are to send the settings to the host Factory default is set as opening programming mode.
  • Page 10: Default Setting

    No Sending Programming Info Sending Programming Expanded Info Sending Programming All Info Default Setting Factory default All readers have a factory default setting. Scan the “Return to Factory Default”, all the product attributes return to factory default. In case you are most likely to use this code: 1、If the setting is wrong, the reader could not decode the bar code.
  • Page 11: Decode Normal And Inverse Data

    Decode Normal and Inverse Data After scan the decode normal and inverse data, decode the normal bar code first, if it is not success, then decode the inverse bar code. Decode the Normal Data Decode the Normal and Inverse Data Reading Mode Manual Mode Default setting, the scanner starts reading the bar code in pressing the trigger and...
  • Page 12 reading code till the user press the trigger button again. When defaulted, it is not allowed to repeat reading the same code. Auto Reading In auto reading mode, the decoding time can be set from 0~255s, when the decoding time is set 0, it means no limit time for reading code. Decoding Time When scan the enable repeat the same code, the scanner will read one code and automatically read the next code;...
  • Page 13: Auto-Sensor Mode

    2、Read the number “5” “0” 3、Save the setting Decoding Different Code Interval The Interval unit is 100ms, set from 0~25.5s. For example: the interval is set as 5000ms, the setting is as below: 1、Read “Decoding Different Code Interval” 2、Read the number“5” “0” 3、Save the setting Auto-Sensor Mode After the setting, the scanner will detect the environment without trigger.
  • Page 14: Command Trigger Reading Mode

    Sensitivity is the sense degree that the scanner detects the surrounding change environment in decoding. Users can set the sensitive according to their own using environment to improve the decode efficiency. High Sensitivity Medium Sensitivity Low Sensitivity Custom Sensitivity In auto-sensor mode, the sensitivity is set from 0-255, the smaller value, the higher sensitivity level.
  • Page 15: Other Settings

    Speaker Close the Speaker Open the Speaker Low Frequency Volume Medium Frequency Volume High Frequency Volume Volume Length 40ms Volume Length 80ms Volume Length 120ms Other Settings Temporary Mute Setting The setting is temporary, when the scanner is reset or power off, the setting will turn to be close mute automatically.
  • Page 16: Communications

    Reading LED On Communications Brief The reader can used for the interfaces of RS232、USB VCOM、USB-KBW、 USB-POS、PS2-KBW. RS232 is usable when no connecting to other interfaces. The scanner needed to be set with the related baud rate before using. Other interfaces could be converted to each other with setting, defaulted is USB-KBW.
  • Page 17: Check

    Baud Rate is the transmission bit(8 bits one byte) per second in RS232 communication. The reader should keep the same baud rate with the host to ensure accurate data transmission. The reader support the baud rate unit is bit/s as below: Baud Rate 9600 Baud Rate 1200 Baud Rate 2400...
  • Page 18: Stop Bit

    Stop Bit 1 Stop Bit 2 Stop Bits Fluid Control None RTS_CTS Data Bit 8 Data Bits 8 Data Bits, None Serial Parity, 1 Stop Bit 8 Data Bits, Even Serial Parity, 1 Stop Bit 8 Data Bits, Odd Serial Parity, 1 Stop Bit 8 Data Bit, None Serial Parity, 2 Stop Bits 8 Data Bits, Even Serial Parity, 2 Stop Bits 8 Data Bits, Odd Serial Parity, 2 Stop Bits...
  • Page 19: Kbw Settings

    7 Data Bits, Even Serial Parity, 2 Stop Bit 7 Data Bits, Odd Serial Parity, 2 Stop Bit KBW Settings Keyboard Wedge Three Input Mode: Keyboard Standard Input Mode Standard Input Mode Wand Emulation In order to input any ASCII character (16 hexadecimal value from 0x00~0xff)in any kind of language, the wand emulation can be set as wand emulation input character mode.
  • Page 20 Emulation Input Control Characters The 16 HEX from 0x00~0x1F of ASCII values could be matched to some control function keys. In emulation keyboard, the control function keys input as the following: the specific ASCII values match the keys details see below table 1、Keep pressing “Ctrl”...
  • Page 21 Crtl+I DownArrow Crtl+J Crtl+K Delete Forward Crtl+L Enter Crtl+M Insert Crtl+N Escape Crtl+O Crtl+P Home Crtl+Q PrintScreen Crtl+R Delete Crtl+S tab+shift Crtl+T Crtl+U Crtl+V Crtl+W Crtl+X Crtl+Y Crtl+Z Crtl+ [ Crtl+\ Crtl+] Crtl+6 Crtl+ - The last five “Function Key Mapping” as above table, character 0X1B~0X1F...
  • Page 22: Emulation Number Mini Keyboard

    corresponding layout is US keyboard, if it is other country keyboard, see the value as below: Country Code United States Belgium < Scandinavia < France Germany à Italy Switzerland < ¢ United Kingdom [ Denmark Norway Spain Emulation Number Mini Keyboard Close this function, all output data is as big keyboard corresponding keys.
  • Page 23: Keyboard Layout

    Keyboard Layout No.1: US English No.2: Belgium No.3: Brasil No.4: Canada No.5: Czechoslovakia No.6: Denmark No.7: Finland No.8: France No.9: Austria No.10: Greece No.11: Hungary No.12: Israel No.13: Italy No.14:Latin America No.15: Netherland No.16: Norway No.17: Poland No.18: Portugal...
  • Page 24: Time-Delay Between Characters

    No.19: Romania No.20: Russia No.21: Slovakia No.22: Spain No.23: Sweden No.24: Switzerland No.25: Turkey 1 No.26: Turkey 2 No.27: English No.28: Japan Time-delay Between Characters Time-delay between characters from 0~15ms ,the unit is 5ms,total 3 class,default is 0ms. No Delay 5ms Delay 10ms Delay 15ms Delay...
  • Page 25: F1~F12

    No Conversion All Capital Letter All Lower-Case Letter Case Conversion F1~F12 In mode of USB-KBW and PS2-KBW,for user’s convenience to use F1~F2 with the following setting: KBW Output F1 KBW Output F2 KBW Output F3 KBW Output F4 KBW Output F5 KBW Output F6 KBW Output F7 KBW Output F...
  • Page 26: Data Format

    Data Format Brief The scanner reads the bar code and outputs the data which could be number, letter and character, etc. The data is the information of the bar code. In the practical application, we may require not only a bar code data, or say that the bar code containing the data which can not meet your requirement.
  • Page 27: User-Defined Prefix

    User-Defined Prefix Enable or Disable User-Defined Prefix User-Defined prefix is to add the characters before the code, the characters should not more than 5 digits. For example, enable user-defined prefix and set it as “AB”, code is “123”, the scanner will add “AB” before the code “123”, and output on terminal shows “AB123”. Disable User-Defined Prefix Enable User-Defined Prefix Define the User-Defined Prefix...
  • Page 28: Aim Id Prefix

    AIM ID Prefix AIM is abbreviation of Automatic Identification Manufacturers, AIMID defines the identification code for each type of standard code, details see the appendix AIM ID. The scanner can add the ID before the bar code after decoding, which is AIMID prefix. Disable AIM-ID Output Enable AIM-ID Output Code ID Prefix...
  • Page 29: Define The User-Defined Suffix

    “123AB”. Disable User-Defined Suffix Enable User-Defined Suffix Define the User-Defined Suffix Firstly read “Enable User-Defined Suffix”, and read the every byte’s 16 hex value of set suffix in turn. Enable Suffix Example --------------------------------------------------------------------------------------------------- ------------ Set User-Defined Suffix as “AGE” (16 Hex Value is0x41/0x47/0x45): 1.
  • Page 30: Define Tailed Suffix

    code and prefix, etc that could be formated, but the tailed suffix could not. Disable Tailed Suffix Enable Tailed Suffix Define Tailed Suffix Firstly read “Enable Tailed Suffix”, and read the every byte’s 16 hex value of set prefix in turn. Enable Tailed Suffix Enable Tailed Suffix 0x0D Enable Tailed Suffix 0x0D,0x0A...
  • Page 31: Code Parameters Setting

    Code Parameters Setting Brief Every type code has its own unique attributes, the settings from this chapter can adjust the reader to adapt to the different attributes. You can also ban the reader not to read the code not to be used to improve the performance. Open/Close 1D Code Disable All Code Types After read the “Disable All Code Types”, the reader can read the setting code only,...
  • Page 32: Code 128

    Code 128 Return to Default After reading this code, all the parameters of Code 128 will be returned to factory default. Return Code128 to Default Enable/Disable Code 128 *Enable Code 28 Disable Code 128 Code ID Read “Enable CodeID”to start the setting, then scan the corresponding 16 HEX Value of CodeID character and save.
  • Page 33: Ucc/Ean-128

    not be able to read or transmit the code. Read “Minimum Length” to set the minimum length of code. Read “Maximum Length” to set maximum length of code. Code 128 Maximum Length Code 128 Minimum Length The maximum length value of any type of 1D code is not more than 255. If the maximum length is shorter than the minimum length, the scanner can only read this two length of code;...
  • Page 34: Code Id

    Code ID Read “Enable CodeID”to start the setting, then scan the corresponding 16 HEX Value of CodeID character and save. UCC/EAN-128- Enable CODEID Set the CodeID of UCC/EAN-128 as“p” (16 HEX Value is 0x70) : 1. Read above “Enable CodeID” 2.
  • Page 35: Aim 128

    AIM 128 Return to Default After read this setting, the parameters of AIM 128 will be returned to factory default. Return AIM 128 to Default Enable/Disable AIM 128 Enable AIM 128 Enable as Code 128 Disable AIM 128 Code ID Read “Enable CodeID”to start the setting, then scan the corresponding 16 HEX Value of CodeID character and save.
  • Page 36: Ean-8

    the limit is from the minimum to maximum value (including the minimum and maximum value), the unit is character. If the length of code AIM 128 is out of the limit, the scanner will not be able to read or transmit the code. Read “Minimum Length”...
  • Page 37: Code Id

    Code ID Read “Enable CodeID”to start the setting, then scan the corresponding 16 HEX Value of CodeID character and save. EAN-8 - Enable CODEID Set the CodeID of EAN-8 as“p” (16 HEX Value is 0x70) : 1. Read above “Enable CodeID” 2.
  • Page 38: Expanding Setting

    Expanding Setting “No Expanding to 13 Digit EAN-13” is to keep the same code type and digits, no expansion. “Expanding to 13 Digit-Front Add 0” is to expand the code digit but not change the code type. “Expanding and Converted to be EAN-13” is to expand the code type and digits. No Expanding to 13 Digit EAN-13 Expanding to 13 Digit-Front Add 0 Expanding and Converted to EAN-13...
  • Page 39: Enable/Disable Ean-13

    Enable/Disable EAN-13 Enable EAN-13 Disable EAN-13 Code ID Read “Enable CodeID”to start the setting, then scan the corresponding 16 HEX Value of CodeID character and save. EAN-13 Enable CODEID Set the CodeID of EAN-13 as“p” (16 HEX Value is 0x70) : 1.
  • Page 40: Enable/Disable 2 &5 Digit Supplements

    Enable/Disable 2 &5 Digit Supplements To enable one of the “Enable Supplements - 2 Digits Only” and “Enable Supplements - 5 Digits Only”, this setting will be valid. No Require 2 or 5 Digit Supplements Require 2 or 5 Digit Supplements Enable or Disable Check Digit Code EAN-13 has 13 characters, the number 13 is check digit which use to make sure the correctness of the all 13 characters.
  • Page 41: Code Id

    Code ID Read “Enable CodeID”to start the setting, then scan the corresponding 16 HEX Value of CodeID character and save. ISSN - Enable CODEID Set the CodeID of ISSN as“p” (16 HEX Value is 0x70) : 1. Read above “Enable CodeID” 2.
  • Page 42: Isbn Data Bit

    ISBN Data Bit 13 Data Bits 10 Data Bits Code ID Read “Enable CodeID”to start the setting, then scan the corresponding 16 HEX Value of CodeID character and save. ISBN - Enable CODEID Set the CodeID of ISBN as“p” (16 HEX Value is 0x70) : 1.
  • Page 43: Code Id

    Code ID Read “Enable CodeID”to start the setting, then scan the corresponding 16 HEX Value of CodeID character and save. UPC-E - Enable CODEID Set the CodeID of UPC-E as“p” (16 HEX Value is 0x70) : 1. Read above “Enable CodeID” 2.
  • Page 44: Enable / Disable Country Code、System Code36

    No Require 2 or 5 Digit Supplements Require 2 or 5 Digit Supplements Enable / Disable Country Code、System Code Disable Country Code, Disable System Code Disable Country Code, Enable System Code Enable Country Code, Enable System Code Expanding Setting “No Expanding ” is to keep the same code type and digits, no expansion. “Expanding to UPC-A”...
  • Page 45: Return To Default

    UPC-A Return to Default After read this setting, the parameters of UPC-A will be returned to factory default Return UPC-A to Default Enable/Disable UPC-A Enable UPC-A Enable as EAN-13 Disable UPC-A Code ID Read “Enable CodeID”to start the setting, then scan the corresponding 16 HEX Value of CodeID character and save.
  • Page 46: Enable/Disable 5 Digit Supplements

    Disable Supplement - 2 Digit Only Enable Supplement - 2 Digit Only Enable/Disable 5 Digit Supplements 2 supplements - to add 2 digits after the code Disable Supplement - 5 Digit Only Enable Supplement - 5 Digit Only Enable/Disable 2&5 Digit Supplements To enable one of the “Enable Supplements - 2 Digits Only”...
  • Page 47: Interleaved 2 Of 5

    Enable Check Digit Disable Check Digit Interleaved 2 of 5 Return to Default After read this setting, the parameters of Interleaved 2 of 5 will be returned to factory default Return Interleaved 2 of 5 to Default Enable/Disable Interleaved 2 of 5 Enable Interleaved 2 of 5 Disable Interleaved 2 of 5 Code ID...
  • Page 48: Check

    Check Interleaved 2 of 5 not limit to include the check digit, if there is check digit, the last character will be. Check digit is the counted value according to all the data, which used to check the correctness of the data. If check digit is “None”, the scanner will transfer the code data normally.
  • Page 49: Itf-6

    maximum length is shorter than the minimum length, the scanner can only read this two length of code; if the maximum length is equal to minimum length, the scanner can only read the code of this length. This length is the length of the code itself, not including prefix/suffix, tailed suffix, AIM-ID,CODEID.
  • Page 50: Itf-14

    2. Read number “7” , “0” (See Appendix- Data Code) 3. Read “Save” ITF-14 Return to Default After read this setting, the parameters of ITF-14 will be returned to factory default Return ITF-14 to Default Enable/Disable ITF-14 Enable ITF-14 No Transmit Check Character Enable ITF-14 Transmit Check Character Disable ITF-14 Code ID...
  • Page 51: Deutsche 14

    Deutsche 14 Return to Default After read this setting, the parameters of Deutsche 14 will be returned to factory default. Return Deutsche 14 to Default Enable/Disable Deutsche 14 Enable Deutsche 14 No Transmit Check Character Disable Deutsche 14 Enable Deutsche 14 Transmit Check Character Code ID Read “Enable CodeID”to start the setting, then scan the corresponding 16 HEX Value of CodeID character and save.
  • Page 52: Deutsche 12

    Deutsche 12 Return to Default After read this setting, the parameters of Deutsche 12 will be returned to factory default Return Deutsche 12 to Default Enable/Disable Deutsche 12 Enable Deutsche 12 No Transmit Check Character Disable Deutsche 12 Enable Deutsche 12 Transmit Check Character Code ID Read “Enable CodeID”to start the setting, then scan the corresponding 16 HEX Value of CodeID character and save.
  • Page 53: Matrix 2 Of 5(European Matrix 2 Of 5)

    Matrix 2 of 5(European Matrix 2 of 5) Return to Default After read this setting, the parameters of Matrix 2 of 5 will be returned to factory default Return Matrix 2 of 5 to Default Enable/Disable Matrix 2 of 5 Enable Matrix 2 of 5 Disable Matrix 2 of 5 Code ID...
  • Page 54: Code Length Limit

    If “check and no transmit check digit”, the scanner will take the last character as check digit. If check success , the scanner will transmit the normal data except for the check digit, if check fail, the scanner will not read the code. If “check and transmit the check character”, the scanner will the last character as check digit.
  • Page 55: Industrial 25

    Industrial 25 Return to Default After read this setting, the parameters of Industrial 25 will be returned to factory default. Return Industrial 25 to Default Enable/Disable Industrial 25 Enable Industrial 25 Disable Industrial 25 Code ID Read “Enable CodeID”to start the setting, then scan the corresponding 16 HEX Value of CodeID character and save.
  • Page 56: Code Length Limit

    If “check and no transmit check digit”, the scanner will take the last character as check digit. If check success , the scanner will transmit the normal data except for the check digit, if check fail, the scanner will not read the code. If “check and transmit the check character”, the scanner will the last character as check digit.
  • Page 57: Standard 25

    Standard 25 Return to Default After read this setting, the parameters of Standard 25 will be returned to factory default. Return Standard 25 to Default Enable/Disable Standard 25 Enable Standard 25 Disable Standard 25 Code ID Read “Enable CodeID”to start the setting, then scan the corresponding 16 HEX Value of CodeID character and save.
  • Page 58: Code Length Limit

    If “check and no transmit check digit”, the scanner will take the last character as check digit. If check success , the scanner will transmit the normal data except for the check digit, if check fail, the scanner will not read the code. If “check and transmit the check character”, the scanner will the last character as check digit.
  • Page 59: Code 39

    Code 39 Return to Default After read this setting, the parameters of Code 39 will be returned to factory default Return Code 39 to Default Enable/Disable Code 39 Eanble Code 39 Disable Code 39 Code ID Read “Enable CodeID”to start the setting, then scan the corresponding 16 HEX Value of CodeID character and save.
  • Page 60: Enable/Disable Start And End Character

    If “check and no transmit check digit”, the scanner will take the last character as check digit. If check success , the scanner will transmit the normal data except for the check digit, if check fail, the scanner will not read the code. If “check and transmit the check character”, the scanner will the last character as check digit.
  • Page 61: Codabar

    limit is from the minimum to maximum value (including the minimum and maximum value), the unit is character. If the length of Code 39 is out of the limit, the scanner will not be able to read or transmit the code. Read “Minimum Length”...
  • Page 62: Code Id

    Code ID Read “Enable CodeID”to start the setting, then scan the corresponding 16 HEX Value of CodeID character and save. Codabar - Enable CODEID Set the CodeID of Codabar as“p” (16 HEX Value is 0x70) : 1. Read above “Enable CodeID” 2.
  • Page 63: Start And End Character

    Start and End Character Disable Start and End Character Enable Start and End Character ABCD/ABCD As Start and End Character ABCD/TN*E As Start and End Character abcd/abcd As Start and End Character abcd/tn*e As Start and End Character Code Length Limit The scanner can only read the the code length within the limited of Codabar, the limit is from the minimum to maximum value (including the minimum and maximum value), the unit is character.
  • Page 64: Code 93

    Code 93 Return to Default After read this setting, the parameters of Code 93 will be returned to factory default. Return Code 93 to Default Enable/Disable Code 93 Enable Code 93 Disable Code 93 Code ID Read “Enable CodeID”to start the setting, then scan the corresponding 16 HEX Value of CodeID character and save.
  • Page 65: Code Length Limit

    If “check and no transmit check digit”, the scanner will take the last character as check digit. If check success , the scanner will transmit the normal data except for the check digit, if check fail, the scanner will not read the code. If “check and transmit the check character”, the scanner will the last character as check digit.
  • Page 66: Code 11

    Code 11 Return to Default After read this setting, the parameters of Code 11 will be returned to factory default. Return Code 11 to Default Enable/Disable Code 11 Enable Code 11 Disable Code 11 Code ID Read “Enable CodeID”to start the setting, then scan the corresponding 16 HEX Value of CodeID character and save.
  • Page 67: Code Length Limit

    None 1 Check Digit, MOD11 2 Check Digits, MOD11/MOD11 2 Check Digits, MOD11/MOD9 MOD11 Single Check (Len <= 10) MOD11 Single Check(Len <= 10) MOD11/MOD11 Double Check (Len > 10) MOD11/MOD9 Double Check (Len > 10) No Transmit Check Digit Transmit Check Digit Code Length Limit The scanner can only read the the code length within the limited of Code 11 the...
  • Page 68: Plessey

    AIM-ID,CODEID. Plessey Return to Default After read this setting, the parameters of Plessey will be returned to factory default. Return Plessey to Default Enable/Disable Plessey Enable Plessey Disable Plessey Code ID Read “Enable CodeID”to start the setting, then scan the corresponding 16 HEX Value of CodeID character and save.
  • Page 69: Code Length Limit

    used to check the correctness of the data. If check digit is “None”, the scanner will transfer the code data normally. None Check But No Transmit Check Digit Check and Transmit Check Digit Code Length Limit The scanner can only read the the code length within the limited of Plessey the limit is from the minimum to maximum value (including the minimum and maximum value), the unit is character.
  • Page 70: Msi-Plessey

    MSI-Plessey Return to Default After read this setting, the parameters of MSI-Plessey will be returned to factory default. Return MSI-Plessey to Default Enable/Disable MSI-Plessey Enable MSI-Plessey Disable MSI-Plessey Code ID Read “Enable CodeID”to start the setting, then scan the corresponding 16 HEX Value of CodeID character and save.
  • Page 71: Code Length Limit

    None 1 Check,MOD10 2 Check, MOD10/MOD10 2 Check MOD10/MOD11 Disable Check Digit Enable Check Digit Code Length Limit The scanner can only read the the code length within the limited of MSI-Plessey the limit is from the minimum to maximum value (including the minimum and maximum value), the unit is character.
  • Page 72: Enable/Disable Rss-14

    Enable/Disable RSS-14 Enable RSS-14 Disable RSS-14 Enable/Disable AI of RSS-14 Enable AI of RSS-14 Disable AI of RSS-14 Code ID Read “Enable CodeID”to start the setting, then scan the corresponding 16 HEX Value of CodeID character and save. RSS-14 - Enable CODEID Set the CodeID of RSS-14 as“p”...
  • Page 73: Enable/Disable Rss- Limited

    Enable/Disable RSS- Limited Enable RSS- Limited Disable RSS- Limited Enable/Disable AI of RSS_Limited Enable AI of RSS-Limited Disable AI of RSS-Limited Code ID Read “Enable CodeID”to start the setting, then scan the corresponding 16 HEX Value of CodeID character and save. RSS-Limited - Enable CODEID Set the CodeID of RSS- Limited as“p”...
  • Page 74: Enable/Disable Rss-Expand

    Return RSS-Expand to Default Enable/Disable RSS-Expand Enable RSS-Expand Disable RSS-Expand Code ID Read “Enable CodeID”to start the setting, then scan the corresponding 16 HEX Value of CodeID character and save. RSS-Expand - Enable CODEID Set the CodeID of RSS-Expand as“p” (16 HEX Value is 0x70) : 1.
  • Page 75 Safety Class Class Medium Frequency Speaker Good Read Indicator Volume,80ms Repeat Reading Same Auto Reading Mode and Auto-Sensor Code Mode Valid Communication Baud Rate 9600 Serial Parity Check None Stop Bit 1 Stop Bit Fluid Control Data Bit 8 Data Bit USB Virtual Keyboard Virtual Keyboard Layout No.1 US Enaglish Keyboard...
  • Page 76 Code Parameters Setting General Disable All Code AIM ID 1 of 2 Enable All Code AIM ID Code 128 Enable Maximum Length Minimum Length UCC/EAN-128 Enable Maximum Length Minimum Length AIM 128 Enable Enable as Code128 Maximum Length Minimum Length EAN-8 Enable Enable Check Digit...
  • Page 77 Enable Check Digit Enable 2 Digit Supplements Enable 5 Digit Supplements Require Supplement ISSN Enable Enable as EAN-13 ISBN Enable Enable as EAN-13 Use 10 Check ISBN UPC-E Enable Enable Check Digit Enable 2 Digit Supplements Enable 5 Digit Supplements Require Supplement Expanded as UPC-A Expanding, Type changed as UPC-A...
  • Page 78 Enable Check Enable Check Digit Maximum Length Minimum Length Shortest Length is more than 1 ITF-6 Enable Enable as Interleaved 2 of 5 Enable Check Digit ITF-14 Enable Enable as Interleaved 2 of 5 Enable Check Digit Deutsche 14 Enable Enable as Interleaved 2 of 5 Enable Check Digit Deutsche 12...
  • Page 79 Enable Check Digit Maximum Length Minimum Length Shortest Length is more than 1 Standard 25 Enable Check Enable Check Digit Maximum Length Minimum Length Shortest Length is more than 1 Code 39 Enable Check Enable Check Digit Enable Start and End Character Enable Full ASCII Maximum Length Minimum Length...
  • Page 80 Maximum Length Minimum Length Shortest Length is more than 1 Code 93 Enable Check Enable Check Digit Maximum Length Minimum Length Shortest Length is more than 1 Code 11 Enable Enable Check Digit No Check 1 of 6 1Digit MOD11 Check 2Digit MOD11/MOD11Check 2Digit MOD11/MOD9 Check Auto2Digit MOD11/MOD11...
  • Page 81: Data Code

    Enable Enable Check Digit No Check 1 of 4 1Digit MOD10 Digit 2 Check Digit MOD10/MOD10 2 Check Digit MOD10/MOD11 Maximum Length Minimum Length Shortest Length is more than 1 GS1-RSS14 Enable GS1-RSSLimited Enable GS1-RSSExpand Enable Data Code After read the data code and then read the “Save” to store the data.
  • Page 82: Save And Cancel Setting

    Save and Cancel Setting After read the data code and then read the save setting to store the data. When read the wrong number, can reset it or cancel the wrong number. Read one setting, and read “1” , “2” , “3” in turn. If you scan “Cancel the Previous Parameter”, the scanner will cancel the number “3”.
  • Page 83: Aimid Table

    Cancel the Previous All Parameters AIMID Table Code Type AIM ID Remark Code 128 Normal Code 128 UCC/EAN 128 First Code :FNC1 (GS1-128) AIM 128 Second Code:FNC1 Normal EAN-8 EAN-8 ]E4….]E1… EAN-8 & 2 Addon ]E4….]E2… EAN-8 & 5 Addon Normal EAN-13 EAN-13 EAN-13 &...
  • Page 84 Code Type AIM ID Remark No Transmit Check Digit Deutsche 14 Deutsche 12 No Check Matrix 2 of 5 Check and Transmit Check Digit Check and No Transmit Check Digit Industrial 2 of 5 No Specific Mark No Check MOD 7 Check and No Transmit Check Standard 2 of 5 Digit MOD 7 Check and Transmit Check...
  • Page 85 Code Type AIM ID Remark Check and Transmit Check Digit Check and No Transmit Check Digit Code 93 No Specific Mark MOD11Single Check,Transmit Check Digit MOD11/MOD11Double Check,Transmit Check Digit Code 11 Check and No Transmit Check Digit MOD11/MOD9Double Check,Transmit Check Digit No Check Plessey No Specific Mark...
  • Page 86: Codeid Table

    CODEID Table Code Ty Code ID Code Ty Code ID Code 128 Deutsche 12 UCC/EAN-128 Matrix 2 of 5(European Matrix 2 of 5) AIM 128 Industrial 25 SETTING 128 Standard 25 EAN-8 Code 39 EAN-13 Codabar ISSN Code 93 ISBN Code 11 UPC-E Plessey...

Table of Contents