  • Page 1 U s e r ’ s M a n u a l VEGA Linear Imager V-1010/V-1010BT Handheld Bar code Scanner...
  • Page 2 EMEA SCANTECH-ID BV Nijverheidsweg Noord 60-34 3812 PM Amersfoort The Netherlands Tel:+31-33-4698400 Fax:+31-33-4650615 E-mail:info@scantech-id.com www.scantech-id.com HEAD QUARTER CHAMPTEK INCORPORATED 5/F, No.2 Alley 2, Shih-Wei Lane, Chung Cheng Rd., Hsin Tien City, Taipei 231,Taiwan Tel:+886-2-2219-2385 Fax:+886-2-2219-2387 E-mail:sales@champtek.com www.champtek.com China CHAMPTEK INCORPORATED #901, No.
  • Page 3 This manual is copyrighted, with all rights reserved. Under the copyright laws, this manual may not, in whole or in part, be copied, photocopied, reproduced, translated or converted to any electronic medium or machine readable form without prior written consent of Scantech-ID BV.
  • Page 4 In particular, Scantech-ID BV shall not be liable for any hardware, software, or data that is stored or used with the product, including the cost of repairing, replacing or recovering the above.
  • Page 5: Table Of Contents

    FCC Warning ..............7 Scanner Labelling ............8 Chapter 2 General Description 9 Use of the VEGA ............10 Chapter 3 Installation of the VEGA V-1010 11 Unpacking ..............12 Mounting ...............13 Chapter 4 Installation of the VEGA V-1010BT 14 Unpacking ..............15 Cradle Installation ............16...
  • Page 6 Chapter 6 Configuring the VEGA 25 Preface ................. 26 Factory Default Setting ..........28 Chapter 7 Programming Codes 29 General Process ............30 Interface Selection ............32 7.3 Bluetooth Scanner Setup....33 Bluetooth Cradle Setup ..........36 Scanner Operation ............37 RS232 Mode Parameters ..........
  • Page 7 Scantech-ID VEGA Linear Imager Chapter 8 Miscellaneous Parameters 83 Bar Code ID..............84 Preambles and Postambles Insertion ......87 Character Deletion ............92 Appendices ....................97 A Decimal Value Table ............98 B ASCII Table ................99 C Function Key Table ............105 D Readable Symbologies .............106 E Technical Specifications ............107...
  • Page 8: Introduction

    POS environment. Quality and Durability The VEGA comes with the same top quality as all other Scantech-ID products. So at a very competitive price the same quality and performance of more expensive products is available. Due to the high MTBF times of every component a long and service free operation time is secured.
  • Page 9: Chapter 1 Product Safety

    Chapter 1 Product Safety...
  • Page 10: Safety & Caution

    Installation of the VEGA V-1010 SAFETY & CAUTION Please read the following safety statement carefully. Please preserve this user manual for reference sometime. Before cleaning the VEGA, the users must cut off all AC power. Do not use liquid or spray type of detersive to clean the VEGA. Please use dampish cotton cloth to clean the VEGA.
  • Page 11: Scanner Labelling

    Scantech-ID VEGA Linear Imager Any operation must comply with the conditions below: (a) The equipment will not cause any severe interference. (b) The equipment can avoid any interference from environment. Statement: This product is classified as B class product. In environment this product may cause some interference. In this situation the user may do something to avoid interference.
  • Page 12 The supplier may ask for this number when the scanner needs servicing. Model Name Serial Number Model Name: VEGA V-1010 Linear Imager VEGA V-1010BT Linear Imager Bluetooth Serial Number: Product Serial No. (VA……..) See Appendix F for more information in detail.
  • Page 13: Chapter 2 General Description

    Scantech-ID VEGA Linear Imager Chapter 2 General Description...
  • Page 14: Use Of The Vega

    Installation of the VEGA V-1010 USE OF THE VEGA The VEGA is very ergonomic and modern designed and very user friendly. It can be connected to your POS or Host system trough a RS232 cable, KBW cable, USB cable or with Bluetooth wireless.
  • Page 15: Chapter 3 Installation Of The Vega V-1010

    Scantech-ID VEGA Linear Imager Chapter 3 Installation of the VEGA V-1010...
  • Page 16: Unpacking

    Installation of the VEGA V-1010 V-1010 UNPACKING Unpack the VEGA as follows: 1. Take the VEGA and its accessories out of the box. 2. Remove the packing material. 3. Check the packing list to make sure you have received all of the items ordered.
  • Page 17: Mounting

    Scantech-ID VEGA Linear Imager V-1010 MOUNTING Once you have unpacked all components, you can start installing the VEGA. Installing the VEGA is divided in different steps: 1. Connect the VEGA to the supplied communication cable (RJ45 side). 2. Connect the VEGA communication cable to the POS or Host system.
  • Page 18: Chapter 4 Installation Of The Vega V-1010Bt

    Chapter 4 Installation of the VEGA V-1010BT/V- 1010BT...
  • Page 19: Unpacking

    Scantech-ID VEGA Linear Imager V-1010BT UNPACKING Unpack the VEGA as follows: 1. Take the VEGA and its accessories out of the box. 2. Remove the packing material. 3. Check the packing list to make sure you have received all of the items ordered.
  • Page 20: Cradle Installation

    Configuring the VEGA V-1010BT CRADLE INSTALLATION To set up your VEGA scanner with Bluetooth technology, please follow the next steps. 1. Connect the supplied communication cable at the bottom side of the cradle. 2. Connect the other side of the communication cable to the right connector of your POS or HOST system.
  • Page 21: Setup Bluetooth Communication

    Scantech-ID VEGA Linear Imager V-1010BT SET UP BLUETOOTH COMMUNICATION Before the VEGA scanner can be used for normal operation, Bluetooth communication must be set up between the VEGA scanner and cradle, Scanner client mode or to a Bluetooth application device, Scanner Server mode.
  • Page 22 Configuring the VEGA ATTENTION The VEGA scanner must be charged for a minimum of 8 hours before the scanner can be placed in full operation for the first time. The cradle red led will indicate in red when the scanner is charged.
  • Page 23: Sleep Mode

    Scantech-ID VEGA Linear Imager When control the Bluetooth device to search the scanner, enter pin code (default 00:00:00:00) to setup comport. When VEGA scanner is successful connected, scanner will initiate with short beep sounds. Blue and red led will also blink followed by a long beep sound.
  • Page 24: Chapter 5 Cover Display

    Configuring the VEGA Chapter 5 Cover Display...
  • Page 25: Setup Cover Display

    Scantech-ID VEGA Linear Imager SETUP COVER DISPLAY The VEGA scanner has the opportunity to change the decorative cover display on the top of the scanner into a display that can show our own commercial message. Message Format 5.1.1 Create your own commercial message with the following outline format, use...
  • Page 26 Configuring the VEGA Step 1: Press out the front rubber lid toward the arrow. ➀ Step 2: Pull out the front rubber lid off the ➁ main unit. Step 3: Press out top cover rim from the inner lock. ➂...
  • Page 27 Scantech-ID VEGA Linear Imager Step 4: Press out the other side of inner lock and remove the complete cover. ➃ Step 5 Assemble transparent top cover rim into inner lock. ➄ Step 6 Assemble another side transparent top cover rim into the inner lock.
  • Page 28 Configuring the VEGA Step 7 Insert your commercial message card into the top cover toward the arrow. ➆ Step 8 Assemble the front rubber lid into the main unit toward the arrow. ➇...
  • Page 29: Chapter 6 Configuring The Vega

    Scantech-ID VEGA Linear Imager Chapter 6 Configuring the VEGA...
  • Page 30: Preface

    Configuring the VEGA PREFACE How to configure the VEGA: The Barcode programming feature gives the possibility to change the VEGA scanner settings with use programming labels. Changing Scanner Settings with Programming 6.1.1 Codes You can set-up your VEGA by scan all necessary programming codes for parameters that meet applications.
  • Page 31 Scantech-ID VEGA Linear Imager Programming Flow Chart 6.1.2 Start Recall Set all Default Configuration Parameters Interface Selection Communication Parameters Bar codes Parameters Misc. Parameters etc. Abort Configuration Configuration Save Parameters...
  • Page 32: Factory Default Setting

    Configuring the VEGA FACTORY DEFAULT SETTING The VEGA is set default with the following settings: RS232 COMMUNICATION DEFAULT V-1010:9600 Baud rate V-1010BT:19200 Parity None Data bits Stop bits RTS/CTS Postamble <CR+LF> DECODER SELECTION DEFAULT All UPC/EAN/JAN Code 11 Code 39 Code 39 Full ASCII Code 32 / Italian Pharmacy Code 128...
  • Page 33: Chapter 7 Programming Codes

    Chapter 7 Programming Codes...
  • Page 34: General Process

    Miscellaneous Parameters GENERAL PROCESS 1 Power up the Scanner Scan the Start of Configuration bar code Scan the bar code for the desired feature. You can scan all features before scanning End of Configuration. 4 Scan End of Configuration bar code 5 Scan Save Parameters bar code Abort Configuration 7.1.1...
  • Page 35: Set All Default

    Scantech-ID VEGA Linear Imager Set All Default 7.1.3 Set all the parameters to the factory default settings Version Information 7.1.4 Display the decoder version information and date code...
  • Page 36: Interface Selection

    Miscellaneous Parameters INTERFACE SELECTION Interface 7.2.1 <Keyboard Mode> RS232 Mode USB Mode...
  • Page 37: Bluetooth Scanner Setup

    Scantech-ID VEGA Linear Imager BLUETOOTH SCANNER SETUP Preface 7.3.1 How to configure the Bluetooth function: The Barcode programming feature gives the possibility to change the VEGA scanner settings with use programming labels. Changing Scanner Settings with Programming 7.3.2 Codes You can set-up Bluetooth function by direct scan all necessary programming codes for Bluetooth parameters.
  • Page 38 Miscellaneous Parameters Memory Read Mode Memory Clear Mode Sleep Mode 7.3.5 <Sleep Mode On 1 minute> Sleep Mode On 10 minute Sleep Mode OFF Scanner Pincode Mode 7.3.6 Default Security code (PINCODE=000000)
  • Page 39 Scantech-ID VEGA Linear Imager Security Code ON Security Code OFF Scanner Pincode Setup 7.3.7 Set PINCODE Max 6 Digits, 0-9 and A-Z ASCII Code Go to ASCII table in Appendix B, scan 6 labels that represents the PINCODE Complete to Set PINCODE...
  • Page 40: Bluetooth Cradle Setup

    Miscellaneous Parameters BLUETOOTH CRADLE SETUP Cradle Pincode Mode 7.4.1 Default Security code (PINCODE=000000) Security Code ON Security Code OFF Cradle Pincode Setup 7.4.2 Set PINCODE Max 6 Digits, 0-9 and A-Z ASCII Code Go to ASCII table in Appendix B, scan 6 labels that represents the PINCODE Complete to Set PINCODE...
  • Page 41: Scanner Operation

    Scantech-ID VEGA Linear Imager SCANNER OPERATION Reading Mode 7.5.1 <Good Read OFF> Trigger ON/OFF Continuous/Trigger OFF Continuous/Auto Power ON Flash Flash/Auto Power ON Testing Good Read LED Control 7.5.2 <Good Read LED ON>...
  • Page 42: Beeper Option

    Miscellaneous Parameters Good Read LED OFF Beeper Option 7.5.3 <High> Medium Reading Level 7.5.4 Bar Equals High <Bar Equals Low> Accurany / Redundant Scan 7.5.5 <Original> - Require 1 good decode for a good scan...
  • Page 43: Reverse Output Characters

    Scantech-ID VEGA Linear Imager 1 Redundant Scan - Require 2 consecutive decodes of the same bar code data for a good scan 2 Redundant Scan - Require 3 consecutive decodes of the same bar code data for a good scan...
  • Page 44: Rs232 Mode Parameters

    Miscellaneous Parameters RS232 MODE PARAMETERS Baud Rate 7.6.1 1200 2400 4800 <9600> for V-1010 <19200> for V-1010BT 38400 57600...
  • Page 45 Scantech-ID VEGA Linear Imager Data/Stop Bits 7.6.2 The number of data bits transmitted for each character 7 Data Bits < 8 Data Bits > < 1 Stop Bits > 2 Stop Bits Parity 7.6.3 A Parity bit is an extra data bit used to help catch data transmission errors.
  • Page 46 Miscellaneous Parameters Handshaking 7.6.4 RTS/CTS ON – Output a Request to Send (RTS) signal and wait for a Clear to Send (CTS) signal before transmitting data RTS/CTS <OFF> ACK/NAK – After transmitting data, wait for host to send an ACK or a NAK response. If ACK is received, then complete the data transmission.
  • Page 47: Keyboard Wedge Mode Parameters

    Scantech-ID VEGA Linear Imager KEYBOARD WEDGE MODE PARAMETERS Terminal Type 7.7.1 <IBM PC/AT,PS/2> - Includes IBM PS/2 and compatible models 50, 55, 60, 80 IBM PC/XT IBM PS/2 25, 30 IBM 5550 IBM 102 Key IBM 122 Key (1) IBM 122 Key (2)
  • Page 48 Miscellaneous Parameters Country/Language 7.7.2 <US English> UK English Italian Spanish French German Swedish Switzerland Hungarian Japanese Belgium...
  • Page 49 Scantech-ID VEGA Linear Imager Portuguese Denmark Netherlands Turkey Upper/Lower Case 7.7.3 <No Change> Enable Lower Case – Transmit all data as lower case Enable Upper Case – Transmit all data as upper case...
  • Page 50: Interscan Code Delay

    Miscellaneous Parameters Interscan Code Delay 7.7.4 <No Delay> 5 ms 10 ms 25 ms 50 ms 100 ms 200 ms 300 ms...
  • Page 51: Output Characters

    Scantech-ID VEGA Linear Imager OUTPUT CHARACTERS Select Terminator 7.8.1 <CR+LF>– The scanner transmits a carriage return and a line feed after each scan CR Suffix – The scanner transmits a carriage return after each scan LF Suffix – The scanner transmits a line feed...
  • Page 52: Code Type

    Miscellaneous Parameters CODE TYPE Barcode Selections 7.9.1 If “Enable” is selected for all bar codes types, then the scanner could read all types of bar code. If “Disable” is selected for a certain bar code type, then the scanner could not read the particular bar code. The symbol of “<>” means default settings.
  • Page 53 Scantech-ID VEGA Linear Imager CODE 39 <ON> CODE 39 OFF Standard Code 39 <ON> Full ASCII Code 39 ON Code32 / Italian Pharmacy ON Code32 / Italian Pharmacy <OFF> Code 128 <ON> Code 128 OFF Interleave 2 of 5 <ON>...
  • Page 54 Miscellaneous Parameters Industrial 2 of 5 ON Industrial 2 of 5 <OFF> Matrix 2 of 5 ON Matrix 2 of 5 <OFF> CODE 93 ON CODE 93 <OFF> CODE 11 ON CODE 11 <OFF> MSI/PLESSEY ON MSI/PLESSEY <OFF> Telepen ON Telepen <OFF>...
  • Page 55 Scantech-ID VEGA Linear Imager China Postage ON China Postage <OFF> GS1 DataBar ON GS1 DataBar <OFF> GS1 DataBar Expanded ON GS1 DataBar Expanded <OFF> GS1 DataBar Limited ON GS1 DataBar Limited <OFF>...
  • Page 56: 7.10 Upc/Ean/Jan Parameters

    Miscellaneous Parameters 7.10 UPC/EAN/JAN PARAMETERS Reading Type 7.10.1 UPC-A=EAN-13 ON Add 0 before UPC-A to make it 13 digits. UPC-A = EAN-13 <OFF> ISBN Enable ISBN <Disable> ISSN Enable ISSN <Disable> Decode with Supplement <Auto Discriminate Supplement> Expand UPC-E Enable <Expand UPC-E Disable>...
  • Page 57: Supplemental Setup

    Scantech-ID VEGA Linear Imager EAN8=EAN13 Enable <EAN8=EAN13 Disable> GTIN Format Enable <GTIN Format Disable> Supplemental Setup 7.10.2 <Not Transmit> 2 Digit Supplemental 5 Digit Supplemental 2 & 5 Digit Supplemental...
  • Page 58: Check Digit Transmission

    Miscellaneous Parameters Check Digit Transmission 7.10.3 UPC-A Check Digit Transmission <ON> UPC-A Check Digit Transmission OFF UPC-E Check Digit Transmission <ON> UPC-E Check Digit Transmission OFF EAN-8 Check Digit Transmission <ON> EAN-8 Check Digit Transmission OFF EAN-13 Check Digit Transmission <ON> EAN-13 Check Digit Transmission OFF ISSN Check Digit Transmission <ON>...
  • Page 59: Code 39 Parameters

    Scantech-ID VEGA Linear Imager 7.11 CODE 39 PARAMETERS Type of Code 7.11.1 <Standard Code 39> Full ASCII Code 39 Check Digit Transmission 7.11.2 <Do Not Calculate Check Digit> Calculate Check Digit and Transmit Calculate Check Digit and Not Transmit Output Start/Stop Character 7.11.3...
  • Page 60: Decode Asterisk

    Miscellaneous Parameters Decode Asterisk 7.11.4 Enable <Disable> Set Up Code Length 7.11.5 To set the fixed length: (2 sets Available) 1. Scan the “Begin” programming code of the desired set 2. Go to the Decimal Value Tables in Appendix A, scan programming codes that represents the length to be read.
  • Page 61 Scantech-ID VEGA Linear Imager Set Begin Decimal Value See Appendix A Set Complete Minimum Length Minimum Length Begin Decimal Value See Appendix A Minimum Length Complete...
  • Page 62: Code 128 Parameters

    Miscellaneous Parameters 7.12 CODE 128 PARAMETERS Reading Type 7.12.1 UCC/EAN-128 Enable <UCC/EAN-128 Disable> Check Digit Transmission 7.12.2 Do Not Calculate Check Digit Calculate Check Digit and Transmit <Calculate Check Digit and Not Transmit> Append FNC2 7.12.3 <OFF>...
  • Page 63 Scantech-ID VEGA Linear Imager Set Up Code Length 7.12.4 To set the fixed length: (2 sets Available) 1. Scan the “Begin” programming code of the desired set 2. Go to the Decimal Value Tables in Appendix A, scan programming codes that represents the length to be read.
  • Page 64 Miscellaneous Parameters Minimum Length Begin Decimal Value See Appendix A Minimum Length Complete...
  • Page 65: Interleave 2 Of 5 Parameters

    Scantech-ID VEGA Linear Imager 7.13 INTERLEAVE 2 OF 5 PARAMETERS Check Digit Transmission 7.13.1 <Do Not Calculate Check Digit> Calculate Check Digit and Transmit Calculate Check Digit and Not Transmit Set Up Number of Character 7.13.2 <Even> Brazilian Banking Code 7.13.3...
  • Page 66 Miscellaneous Parameters Set Up Code Length 7.13.4 To set the fixed length: (2 sets Available) 1 Scan the “Begin” programming code of the desired set 2 Go to the Decimal Value Tables in Appendix A, scan programming codes that represents the length to be read. 3 Scan the “Complete”...
  • Page 67 Scantech-ID VEGA Linear Imager Minimum Length Begin Decimal Value See Appendix A Minimum Length Complete...
  • Page 68: Industrial 2 Of 5 Parameters

    Miscellaneous Parameters 7.14 INDUSTRIAL 2 OF 5 PARAMETERS Reading Type 7.14.1 IATA25 Enable <IATA25 Disable> Check Digit Transmission 7.14.2 <Do Not Calculate Check Digit> Calculate Check Digit and Transmit Calculate Check Digit and Not Transmit...
  • Page 69 Scantech-ID VEGA Linear Imager Set Up Code Length 7.14.3 To set the fixed length: (2 sets Available) 1 1Scan the “Begin” programming code of the desired set 2 Go to the Decimal Value Tables in Appendix A, scan programming codes that represents the length to be read.
  • Page 70 Miscellaneous Parameters Minimum Length Begin Decimal Value See Appendix A Minimum Length Complete...
  • Page 71: Matrix 2 Of 5 Parameters

    Scantech-ID VEGA Linear Imager 7.15 MATRIX 2 OF 5 PARAMETERS Check Digit Transmission 7.15.1 <Do Not Calculate Check Digit> Calculate Check Digit and Transmit Calculate Check Digit and Not Transmit Set Up Code Length 7.15.2 To set the fixed length: (2 sets Available) 1 Scan the “Begin”...
  • Page 72 Miscellaneous Parameters Set Begin Decimal Value See Appendix A Set Complete Fixed Length 2 Set Begin Decimal Value See Appendix A Set Complete Minimum Length Minimum Length Begin Decimal Value See Appendix A Minimum Length Complete...
  • Page 73: Codabar/Nw7 Parameters

    Scantech-ID VEGA Linear Imager 7.16 CODABAR/NW7 PARAMETERS Set Up Start/Stop Characters upon Transmission 7.16.1 <OFF> Transmission Type of Start/Stop 7.16.2 A/B/C/D <Start> A/B/C/D <Stop> A Start A Stop B Start B Stop...
  • Page 74 Miscellaneous Parameters C Start C Stop D Start D Stop Set Up Code Length 7.16.3 To set the fixed length: (2 sets Available) 1 Scan the “Begin” programming code of the desired set 2 Go to the Decimal Value Tables in Appendix A, scan programming codes that represents the length to be read.
  • Page 75 Scantech-ID VEGA Linear Imager Set Begin Decimal Value See Appendix A Set Complete Fixed Length 2 Set Begin Decimal Value See Appendix A Set Complete Minimum Length Minimum Length Begin Decimal Value See Appendix A Minimum Length Complete...
  • Page 76: Code 93 Parameters

    Miscellaneous Parameters 7.17 CODE 93 PARAMETERS Check Digit Transmission 7.17.1 Do Not Calculate Check Digit <Calculate Check 2 Digit and Not Transmit> Set Up Code Length 7.17.2 To set the fixed length: (2 sets Available) 1 Scan the “Begin” programming code of the desired set 2 Go to the Decimal Value Tables in Appendix A, scan programming codes that represents the length to be read.
  • Page 77 Scantech-ID VEGA Linear Imager Set Begin Decimal Value See Appendix A Set Complete Minimum Length Minimum Length Begin Decimal Value See Appendix A Minimum Length Complete...
  • Page 78: Code 11 Parameters

    Miscellaneous Parameters 7.18 CODE 11 PARAMETERS Check Digit Transmission 7.18.1 <Do Not Calculate Check Digit> Calculate Check 1 Digit and Transmit Calculate Check 1 Digit and Not Transmit Calculate Check 2 Digit and Transmit Calculate Check 2 Digit and Not Transmit Set Up Code Length 7.18.2 To set the fixed length: (2 sets Available)
  • Page 79 Scantech-ID VEGA Linear Imager Set Begin Decimal Value See Appendix A Set Complete Fixed Length 2 Set Begin Decimal Value See Appendix A Set Complete Minimum Length Minimum Length Begin Decimal Value See Appendix A Minimum Length Complete...
  • Page 80: Msi/Plessey Code Parameters

    Miscellaneous Parameters 7.19 MSI/PLESSEY CODE PARAMETERS Check Digit Transmission 7.19.1 <Do Not Calculate Check Digit> Calculate Check Digit and Transmit Calculate Check Digit and Not Transmit Set Up Code Length 7.19.2 To set the fixed length: (2 sets Available) 1. Scan the “Begin” programming code of the desired set 2.
  • Page 81 Scantech-ID VEGA Linear Imager Set Begin Decimal Value See Appendix A Set Complete Fixed Length 2 Set Begin Decimal Value See Appendix A Set Complete Minimum Length Minimum Length Begin Decimal Value See Appendix A Minimum Length Complete...
  • Page 82: Telepen Parameters

    Miscellaneous Parameters 7.20 TELEPEN PARAMETERS Type of Code 7.20.1 Telepen ASCII <ON> Telepen Numeric Check Digit Transmission 7.20.2 Do Not Calculate Check Digit Calculate Check Digit and Transmit <Calculate Check Digit and Not Transmit> Set Up Code Length 7.20.3 To set the fixed length: (2 sets Available) 4.
  • Page 83 Scantech-ID VEGA Linear Imager Fixed Length 1 Set Begin Decimal Value See Appendix A Set Complete Fixed Length 2 Set Begin Decimal Value See Appendix A Set Complete Minimum Length Minimum Length Begin Decimal Value See Appendix A Minimum Length Complete...
  • Page 84: Gs1 Databar Parameters

    Miscellaneous Parameters 7.21 GS1 DATABAR PARAMETERS Check Digit Transmission 7.21.1 <Calculate Check Digit and Transmit> Calculate Check Digit and Not Transmit Application ID 7.21.2 <Transmit Application ID> Add 01 Before GS1 Databar Do Not Transmit Application ID Symbology ID 7.21.3 Transmit Symbology ID Add ]e0 Before GS1 Databar.
  • Page 85: Gs1 Databar Limited Parameters

    Scantech-ID VEGA Linear Imager 7.22 GS1 DATABAR LIMITED PARAMETERS Check Digit Transmission 7.22.1 <Calculate Check Digit and Transmit> Calculate Check Digit and Not Transmit Application ID 7.22.2 <Transmit Application ID> Add 01 Before GS1 Databar Limited. Don’t Transmit Application ID Symbology ID 7.22.3...
  • Page 86: Gs1 Databar Expanded Parameters

    Miscellaneous Parameters 7.23 GS1 DATABAR EXPANDED PARAMETERS Symbology ID 7.23.1 Transmit Symbology ID Add ]e0 Before GS1 Databar Expanded. <Don’t Transmit Symbology ID>...
  • Page 87: Chapter 8 Miscellaneous Parameters

    Scantech-ID VEGA Linear Imager Chapter 8 Miscellaneous Parameters...
  • Page 88: Bar Code Id

    Miscellaneous Parameters BAR CODE ID Default Barcode ID 8.1.1 With this function on, a leading character will be added to the output string while scanning code; user may refer to the following table to know what kind of barcode is being scanned. Code Type Code Type UPC-A...
  • Page 89: User Define Code Id

    Scantech-ID VEGA Linear Imager User Define Code ID 8.1.2 To set the code ID 1. Scan the symbologies programming code. 2. Go to the ASCII Tables in Appendix B, Scan programming codes that represents the desired ID. Note: User defines code ID will override default value. Program will not check the conflict.
  • Page 90 Miscellaneous Parameters Industrial 2 of 5 Matrix 2 of 5 CODE 93 CODE 11 China Postage MSI/PLESSEY Telepen GS1 DataBar GS1 DataBar Expanded GS1 DataBar Limited...
  • Page 91: Preambles And Postambles Insertion

    Scantech-ID VEGA Linear Imager PREAMBLES AND POSTAMBLES INSERTION Setup Insertion 8.2.1 To set the insertion of the output characters; 1. Scan the programming code of the desired set. 2. Scan the programming code of the desired symbology 3. Go to the Decimal Value in Appendix A, scan programming codes that represents the desired position to be inserted (1= the first digit, 99 the last digit).
  • Page 92: Insertion Set Number

    Miscellaneous Parameters Complete End of Configuration Bar Code Save Parameters Bar Code Insertion Set Number 8.2.2...
  • Page 93: Symbologies Selection

    Scantech-ID VEGA Linear Imager Symbologies Selection 8.2.3 UPC-A UPC-E EAN-13/JAN-13 EAN-8/JAN-8 CODE 39 CODE 128 Codabar/NW7 Interleave 2 of 5 Industrial 2 of 5 Matrix 2 of 5 CODE 93...
  • Page 94 Miscellaneous Parameters CODE 11 China Postage MSI/PLESSEY Telepen GS1 DataBar RSS-14 GS1 DataBar Expanded GS1 DataBar Limited All Codes None...
  • Page 95 Scantech-ID VEGA Linear Imager Character Position to be Insertion 8.2.4 Decimal Value See Appendix A Complete Characters to be Inserted 8.2.5 ASCII Table See Appendix B and C Complete...
  • Page 96: Character Deletion

    Miscellaneous Parameters CHARACTER DELETION To setup the deletion of output characters: 1. Scan the programming code of the desired set. 2. Scan the programming code of the desired symbology. 3. Go to the decimal Value tables in Appendix A, scan programming codes that represents the desired position to be deleted.
  • Page 97: Deletion Set Number

    Scantech-ID VEGA Linear Imager Complete End of Configuration Bar Code Save Parameters Bar Code Deletion Set Number 8.3.1...
  • Page 98: Code Type To Be Delete

    Miscellaneous Parameters Code Type to be Delete 8.3.2 UPC-A UPC-E EAN-13/JAN-13 EAN-8/JAN-8 CODE 39 CODE 128 Codabar/NW7 Interleave 2 of 5 Industrial 2 of 5 Matrix 2 of 5 CODE 93...
  • Page 99 Scantech-ID VEGA Linear Imager CODE 11 China Postage MSI/PLESSEY Telepen GS1 DataBar GS1 DataBar Expanded GS1 DataBar Limited All Codes None...
  • Page 100 Miscellaneous Parameters Character Position to be Delete 8.3.3 Decimal Value See Appendix A Complete Number of Characters to be Delete 8.3.4 Decimal Value See Appendix A Complete...
  • Page 101: Appendices

    Appendixes Decimal Value Table ..............98 ASCII Table ................99 Function Key Table ..............105 Readable Symbologies ............106 Technical Specifications ............107 Scan Map ................109 Led Indicator Status .............111 Test Symbologies..............112 Overview Partnumbers ............114...
  • Page 102: Adecimal Value Table

    DECIMAL VALUE TABLE...
  • Page 103: Bascii Table

    Scantech-ID VEGA Linear Imager ASCII TABLE NULL...
  • Page 104 SPACE ″ &...
  • Page 105 Scantech-ID VEGA Linear Imager Comma minus period Number Zero Number One < Less than > Greater than...
  • Page 106 Letter I Letter O...
  • Page 107 Scantech-ID VEGA Linear Imager Underscore...
  • Page 108 Vertical slash...
  • Page 109: Cfunction Key Table

    Scantech-ID VEGA Linear Imager FUNCTION KEY TABLE Insert Delete Home Page Up Page Down Left Right Down...
  • Page 110: D Readable Symbologies

    D READABLE SYMBOLOGIES 1D Symbologies Symbology Default Enable Note Codabar/NW7 Code 11 Code 32 / Italian Pharmacy Code 39 Code 93 Code 128 EAN 8 / EAN 13 EAN 128 GS1 DataBar(RSS) Off Omni, Expanded, limited Interleave 2 of 5 Industrial 2 of 5 ISBN ISSN...
  • Page 111: E Technical Specifications

    Scantech-ID VEGA Linear Imager E TECHNICAL SPECIFICATIONS Physical Characteristics Scanner Scanner Weight (V-1010) Approx 240 gr. Scanner Weight (V-1010BT) Approx 195 gr. (incl. batteries) Cradle Weight Approx. 145g Charger Weight Approx. 135g Material ABS Plastic Connector RJ 45C 10Pins Dimension 186.8 mm x 81.6 mm x 63.9 mm...
  • Page 112 Electrical Characteristics (V-1010 wired model) Operation Voltage 5 VDC ±5% Current Operating 140 mA (max) @ 5 VDC Current Standby 50 mA typical @ 5 VDC AC transformers 5.2 VDC @ 650 mA / Input AC 100-240V Electrical Characteristics (V-1010BT wireless model) Battery Li-ion 3.7V / 1400 mA.
  • Page 113 Scantech-ID VEGA Linear Imager Regulatory of Compliance RoHs...
  • Page 114: F Scan Map

    F SCAN MAP Typical Reading Distances 34°...
  • Page 115 Scantech-ID VEGA Linear Imager VEGA Typical Reading Distances (Centimetres) Symbology Density Minimum Maximum Distance Distance Code 39 10.5 15.5 cm 0.127 mm 10 cm 17 cm 0.25 mm 8 cm 20 cm 0.5 mm 7 cm 27 cm VEGA Typical Reading Distances (inches)
  • Page 116: G Led Indicator Status

    G LED INDICATOR STATUS LIGHT SIGNAL STATUS Good read and transmitted Green 1 Blink and 1 Beep Good read and save on memory (BT Disconnect) 3 Long blink and 3 Long Memory Full Beeps 4 Blink and Beeps Low Battery Warning Good Read 2 Blink and 2 Beeps but Transmit Fail...
  • Page 117: H Test Symbologies

    Scantech-ID VEGA Linear Imager H TEST SYMBOLOGIES Scan one or more of these bar codes to test bar code symbologies you enabled. 1D Symbology Codabar/NW7 CODE 11 CODE 39 CODE 93 CODE 128 EAN 8 1234 5670 EAN 13 Interleave 2 of 5...
  • Page 118: I Overview Partnumbers

    Matrix 2 of 5 Industrial 2 of 5 UPC A UPC E 12345 67890 1 23 456 Telepen China Postage...
  • Page 119 Scantech-ID VEGA Linear Imager OVERVIEW MODEL NUMBERS VEGA with Linear Imager Version with RS232 interface: 1. A271002 VEGA V-1010-02 2. A272002 VEGA V-1010BT C2 -02 3. A275002 VEGA V-1010BT C1 -02 Version with KBW interface: 4. A271003 VEGA V-1010-03 5. A271003 VEGA V-1010BT C2 -03 6.
  • Page 120 Quick Configuration Start Configuration <Select your Settings> End Configuration Save Parameters Set All Defaults Recall Stored Parameters Abort Configuration Version Information...
  • Page 121 Scantech-ID VEGA Linear Imager Scantech-ID BV Nijverheidsweg Noord 60-34 3812 PM Amersfoort The Netherlands Phone: +31 (0)33 469 84 00 Fax: +31 (0)33 465 06 15 E-mail: info@scantech-id.com Internet: www.scantech-id.com...

This manual is also suitable for:

Vega v-1010bt

Table of Contents