Takagi T-KJr2U-IN Installation Manual And Owner's Manual page 17

On-demand water heater
Table of Contents

Advertisement

1 ft.
(305 mm)
1 ft.
(305 mm)
Exhaust
termination
1 ft.
(305 mm)
1 ft.
(305 mm)
Combined
intake and
exhaust
termination
Exhaust
termination
3 ft.
(915 mm)
3 ft.
3 ft.
(915 mm)
(915
mm)
Air supply inlet
A
A
Exhaust termination
A: In accordance with local codes
For multiple-unit rooftop terminations (whether for standard or direct-vent installations) space all
exhaust and intake terminations in accordance with local codes. An exhaust termination must be spaced
from a wall or surface in accordance with local codes as well. In the absence of such a code, an exhaust
termination must be a horizontal distance of at least 2 ft. (610 mm) away from a wall or surface.
Please follow all local and national codes in regards to proper termination
clearances. In the absence of such codes, the following clearances can be used as
guidelines. Local codes supersede these guidelines.
CAUTION
-For sidewall terminations-
For multiple sidewall exhaust terminations (e.g. multi-
2 ft.
unit systems), an exhaust termination must be at least 1
(610 mm)
ft. (305mm) away from another exhaust termination. An
exhaust termination must also be at least 2 ft. (610 mm)
away from an inside corner (if the adjacent wall is less than
2 ft. (610 mm) of length, the minimum required distance
away from the inside corner will be equal to the length of
that adjacent wall).
Inside
corner
For multiple-unit, direct-vent sidewall terminations that
combine the intake and exhaust into a single penetration,
2 ft.
(610 mm)
space each direct-vent termination at least 1 ft. (305 mm)
away from each other, no matter the orientation. A direct-
vent termination must also be at least 2 ft. (610 mm) away
from an inside corner (if the adjacent wall is less than 2 ft.
(610 mm) of length, the minimum required distance away
from the inside corner will be equal to the length of that
adjacent wall).
Inside
corner
For direct-vent sidewall
terminations that use two
separate penetrations for
the intake and exhaust,
distance the intake and
exhaust terminations at
least 3 ft. (915 mm) away
from each other, no
matter the orientation.
-For rooftop terminations-
A
Air intake
17
Exhaust
and/or
direct-vent sidewall
terminations should
be at least 2 ft. (610
mm) away from an
opposite
surface/
wall. Do not place the
termination directly
in front of an opening
.
into a building
2ft.
(610 mm)
Exhaust
termination
Page
Installation Manual
Installation
 2 ft.
(610 mm)
Exhaust
termination
A
A
Air intake