Takagi T-KJr2U-IN Installation Manual And Owner's Manual page 10

On-demand water heater
Table of Contents

Advertisement

1. Backflow Preventer: 9007678005 (TK-BF01)
The Backflow preventer prevents the backflow of
air through the exhaust vent. This helps prevent
harmful exhaust gases from entering the home, as
well as helping to prevent the unit from freezing in
areas where cold air can be blown or drawn into
the exhaust system. Install this vent damper in
accordance with the installation instructions and
any applicable codes.
3. Pipe covers: 9007670005 (TK-PC01)
The pipe cover protects the plumbing pipes to
the water heater from unexpected adjustments.
This pipe cover is fixed to the bottom of the
water heater, which hides the plumbing and
improves the visual aspects of the whole
installation for the water heater.
5. T-Vent Wall Thimble with Termination: 9007608005 (TK-KPWL4) and 9007609005 (TK-KPWH4)
Hood Termination
Louver Termination
9007609005
9007608005
(TK-KPWL4)
(TK-KPWH4
6. Direct-Vent Concentric Termination: 900768005 (TK-KPCT43)
9007680005 (TK-KPCT43-1)
9007772005 (TK-KPCT43-2)
9007773005 (TK-KPCT43-3)
2. Direct-Vent Conversion Kit: 9007667005
These terminations are used when venting out through the wall and
are compatible with the T-Vent pipe system. These terminations are
special stainless steel vents for gas appliances and are UL listed as
Category II, III and IV. There are two types of terminations: the Louver
termination and the Hood termination. For different wall thicknesses,
there are two ranges of lengths available (refer to the T-Vent brochure
for details). Install these vent terminations in accordance with their
)
installation instructions and any applicable local codes.
Used when terminating direct-vent (sealed-combustion) systems, with
direct-vent models that require a 3 in. (76 mm) intake and a 4 in. (102
mm) exhaust. This concentric termination provides the convenience
of only having to make one penetration through a sidewall instead
of two separate penetrations for the intake and exhaust piping. The
termination includes a bird screen, restricting small animals, pests,
and foreign objects from entering into the vent system. This sidewall
termination is available in three different sizes, to cover all ranges of
wall thicknesses.
Part#
9.8 – 13.0 in. (249 - 330 mm)
10
Page
Installation Manual
(TK-TV10)
This kit can be used to convert the water
heater from a standard vent system to a direct-
vent (or sealed combustion) system. Install
this conversion kit in accordance with the
installation instructions and any applicable
codes.
4. Recess box: 9007674005 (TK-RB02)
The Recess box will allow for
"clean" installations. The water
heater fits inside the recess box,
which hides and protects the whole
water heater and plumbing. The
Recess box will fit in-between most
wall studs.
Convering wall thicknesss
3.9 – 7.1 in. (99 - 180 mm)
6.9 – 10.1 in. (175 - 257 mm)
Installation